Intraoperative imaging of zygomaticomaxillary complex fractures using a 3D C-arm system.

After preclinical studies and evaluation of radiation exposures, intraoperative three-dimensional (3D) C-arm based imaging is now available for the facial skeleton. Fourteen patients admitted for surgical treatment of zygomaticomaxillary complex (ZMC) fractures were included in the study. Preoperative diagnostics and surgical treatment were performed as usual. Intraoperatively, after open reduction, a cone-beam computed tomography (CBCT) dataset was generated using the SIREMOBIL Iso-C3D (Siemens Medical Solutions, Erlangen, Germany). After DICOM-import in eFilm Workstation axial, coronal and sagittal reconstructions were evaluated by five examiners with the help of six defined criteria. In our study, secondary reconstructions were available after 6 min, excluding the time needed for the evaluation of the images. Especially the positioning of the isocentre of the SIREMOBIL Iso-C3D proved to be uncomplicated. Because of the size of the datasets, assessment of the symmetry of the malar projection proved difficult. Best scoring results were found regarding the visualization of the fragment position, bony anchorage of the screws and the fitting of the plates. Remarkable was the low level of metal artefacts in primary and secondary reconstructions. In conclusion, our results demonstrate intraoperative CBCT using the SIREMOBIL Iso-C3D suitable for assessment of postoperative results following ZMC reduction.

[1]  P. Manson,et al.  Toward CT‐Based Facial Fracture Treatment , 1990, Plastic and reconstructive surgery.

[2]  Max Heiland,et al.  Midfacial imaging using digital volume tomography , 2003, CARS.

[3]  Rod J. Rohrich,et al.  Optimizing the management of orbitozygomatic fractures. , 1992, Clinics in plastic surgery.

[4]  K Cleary,et al.  Intraoperative computed tomography for complex craniocervical operations and spinal tumor resections. , 2000, Neurosurgery.

[5]  D. Simon,et al.  Virtual Fluoroscopy: Computer-Assisted Fluoroscopic Navigation , 2001, Spine.

[6]  R B Stanley,et al.  Use of intraoperative computed tomography during repair of orbitozygomatic fractures. , 1999, Archives of facial plastic surgery.

[7]  E R Laws,et al.  Fluoroscopic Frameless Stereotaxy for Transsphenoidal Surgery , 2001, Neurosurgery.

[8]  S. Brooks,et al.  Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit. , 2003, Dento maxillo facial radiology.

[9]  M. Heiland,et al.  Dreidimensionale Darstellungsmöglichkeiten des Mittelgesichts mithilfe der digitalen Volumentomographie anhand einer Kadaverstudie zur winkelstabilen Osteosynthese , 2003, Mund-, Kiefer- und Gesichtschirurgie.

[10]  J Brief,et al.  Clinical indications for digital volume tomography in oral and maxillofacial surgery. , 2002, Dento maxillo facial radiology.

[11]  Ekkehard Euler,et al.  Three-dimensional CT with a modified C-arm image intensifier: feasibility. , 2002, Radiology.

[12]  P. Manson,et al.  Comprehensive management of pan-facial fractures. , 1995, The Journal of cranio-maxillofacial trauma.

[13]  A. Ayoub,et al.  Assessment of zygomatico-orbital complex fractures using ultrasonography. , 2000, The British journal of oral & maxillofacial surgery.

[14]  M. Reiser,et al.  Frakturdiagnostik am Kniegelenk mit einem neuen mobilen CT-System (ISO-C-3D): Vergleich mit konventionellem Röntgen und Spiral-CT , 2002 .

[15]  F. Dammann,et al.  Möglichkeiten der intraoperativen Diagnostik mit einem fahrbaren Computertomographen , 2002, Mund-, Kiefer- und Gesichtschirurgie.

[16]  N. Gellrich,et al.  Navigation-guided resection of temporomandibular joint ankylosis promotes safety in skull base surgery. , 2002, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[17]  M. Heiland,et al.  Potentials of ultrasound in the diagnosis of midfacial fractures* , 2003, Clinical Oral Investigations.

[18]  C. Nimsky,et al.  Quantification of, Visualization of, and Compensation for Brain Shift Using Intraoperative Magnetic Resonance Imaging , 2000, Neurosurgery.

[19]  P. Manson Computed tomography use and repair of orbitozygomatic fractures. , 1999, Archives of facial plastic surgery.

[20]  R Schmelzle,et al.  3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil Iso-C3D). , 2003, Dento maxillo facial radiology.

[21]  S. Saini,et al.  Technical cost of CT examinations. , 2001, Radiology.

[22]  K. Hashikawa,et al.  Endoscopic Endonasal Reduction for Blowout Fracture of the Medial Orbital Wall , 2003, Plastic and reconstructive surgery.

[23]  M. Kulkarni,et al.  The role of three-dimensional computed tomography in the management of maxillofacial trauma. , 1988, The Journal of trauma.

[24]  Predrag Sukovic,et al.  Initial performance measurements of the first clinical prototype of DentoCATTM - a Cone Beam CT scanner for dentomaxillofacial Imaging , 2003, CARS.

[25]  I. Gareen,et al.  Transportable versus fixed platform CT scanners: comparison of costs. , 2003, Radiology.

[26]  E. Ellis,et al.  Analysis of treatment for isolated zygomaticomaxillary complex fractures. , 1996, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[27]  P. Mozzo,et al.  A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results , 1998, European Radiology.

[28]  G. Adam,et al.  Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography. , 2004, Dento maxillo facial radiology.

[29]  A. Jödicke,et al.  Intraoperative three-dimensional ultrasonography: an approach to register brain shift using multidimensional image processing. , 1998, Minimally invasive neurosurgery : MIN.

[30]  R. Schmelzle,et al.  Postoperative imaging of zygomaticomaxillary complex fractures using digital volume tomography. , 2004, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[31]  Beat Hammer,et al.  Computer‐Assisted Secondary Reconstruction of Unilateral Posttraumatic Orbital Deformity , 2002, Plastic and reconstructive surgery.

[32]  H. Tonami,et al.  Surface coil MR imaging of orbital blowout fractures: a comparison with reformatted CT. , 1987, AJNR. American journal of neuroradiology.

[33]  V. Seifert,et al.  Laser Surface Scanning for Patient Registration in Intracranial Image-guided Surgery , 2002, Neurosurgery.

[34]  M. Cohnen,et al.  Radiation dose in dental radiology , 2002, European Radiology.

[35]  N Hosten,et al.  Intraoperative computed tomography with the mobile CT Tomoscan M during surgical treatment of orbital fractures. , 2001, International journal of oral and maxillofacial surgery.

[36]  M. Krimmel,et al.  [Feasibility of intraoperative diagnosis with a mobile computed tomography scanner]. , 2002, Mund-, Kiefer- und Gesichtschirurgie : MKG.