General and self-consistent method for the calibration of polarization modulators, polarimeters, and mueller-matrix ellipsometers.

Calibration of polarization-state generators (PSG's), polarimeters, and Mueller-matrix ellipsometers (MME's) is an important factor in the practical use of these instruments. A new general procedure, the eigenvalue calibration method (ECM), is presented. It can calibrate any complete MME consisting of a PSG and a polarimeter that generate and measure, respectively, all the states of polarization of light. In the ECM, the PSG and the polarimeter are described by two 4 x 4 matrices W and A, and their 32 coefficients are determined from three or four measurements performed on reference samples. Those references are smooth isotropic samples and perfect linear polarizers. Their optical characteristics are unambiguously determined during the calibration from the eigenvalues of the measured matrices. The ECM does not require accurate alignment of the various optical elements and does not involve any first-order approximation. The ECM also displays an efficient error control capability that can be used to improve the MME behavior. The ECM is illustrated by an experimental calibration, at two wavelengths (458 and 633 nm), of a MME consisting of a coupled phase modulator associated with a prism division-of-amplitude polarimeter.

[1]  K. Brudzewski Static Stokes Ellipsometer: General Analysis and Optimization , 1991 .

[2]  R. Azzam,et al.  Arrangement of four photodetectors for measuring the state of polarization of light. , 1985, Optics letters.

[3]  R. M. A. Azzam,et al.  Division-of-amplitude Photopolarimeter (DOAP) for the Simultaneous Measurement of All Four Stokes Parameters of Light , 1982 .

[4]  William S. Bickel,et al.  Stokes vectors, Mueller matrices, and polarized scattered light , 1985 .

[5]  Rasheed M. A. Azzam,et al.  Simulation of mechanical rotation by optical rotation: Application to the design of a new Fourier photopolarimeter , 1978 .

[6]  R M Azzam Mueller-matrix measurement using the four-detector photopolarimeter. , 1986, Optics letters.

[7]  B. Drévillon,et al.  Broadband Division-of-Amplitude Polarimeter Based on Uncoated Prisms. , 1998, Applied optics.

[8]  R. Azzam,et al.  Photopolarimetric measurement of the Mueller matrix by Fourier analysis of a single detected signal. , 1978, Optics letters.

[9]  Eric Compain,et al.  High-frequency modulation of the four states of polarization of light with a single phase modulator , 1998 .

[10]  B. Drévillon,et al.  Deposition of SiO2 in integrated distributed electron cyclotron resonance microwave reactor , 1997 .

[11]  S. Krishnan,et al.  Calibration, properties, and applications of the division-of-amplitude photopolarimeter at 632.8 and 1523 nm , 1992 .

[12]  Eric Compain,et al.  Complete high-frequency measurement of Mueller matrices based on a new coupled-phase modulator , 1997 .

[13]  P. S. Hauge,et al.  Mueller matrix ellipsometry with imperfect compensators , 1978 .

[14]  Randall C. Thompson,et al.  Measurement of polarized light interactions via the Mueller matrix: errata. , 1980, Applied optics.

[15]  Rasheed M. A. Azzam,et al.  Accurate calibration of the four-detector photopolarimeter with imperfect polarizing optical elements , 1989 .