Dual-energy CT of the pancreas: improved carcinoma-to-pancreas contrast with a noise-optimized monoenergetic reconstruction algorithm.

PURPOSE To evaluate a novel monoenergetic reconstruction algorithm (nMERA) with improved noise reduction for dual-energy CT (DECT) of pancreatic adenocarcinoma. MATERIALS AND METHODS Sixty patients with suspected pancreatic carcinoma underwent dual-source dual-energy CT with arterial phase. Images were reconstructed as linearly-blended 120-kV series (M_0.6) and with the standard monoenergetic (sMERA) and the novel monoenergetic algorithm (nMERA) with photon energies of 40, 55, 70 and 80 keV. Objective image quality was compared regarding image noise, pancreas attenuation, signal-to-noise ratio (SNR) and pancreas-to-lesion contrast. Subjective image quality was assessed by two observers. RESULTS Thirty pancreatic adenocarcinomas were detected. nMERA showed significantly reduced image noise at low keV levels compared with sMERA images (55 keV: 7.19 ± 2.75 vs. 20.68 ± 7.01 HU; 40 keV: 7.33 ± 3.20 vs. 37.22 ± 14.66 HU) and M_0.6 (10.69 ± 3.57 HU). nMERA pancreatic SNR was significantly superior to standard monoenergetic at 40 (47.02 ± 23.41 vs. 9.37 ± 5.83) and 55 keV (28.29 ± 16.86 vs. 9.88 ± 7.01), and M_0.6 series (11.42 ± 6.00). Pancreas-to-lesion contrast peaked in the nMERA 40 keV series (26.39 ± 16.83) and was significantly higher than in all other series (p<0.001). nMERA 55 keV images series were consistently preferred by both observers over all other series (p<0.01). CONCLUSIONS nMERA DECT can significantly improve image quality and pancreas-to-lesion contrast in the diagnosis of pancreatic adenocarcinoma.

[1]  Thomas Henzler,et al.  Optimization of kiloelectron volt settings in cerebral and cervical dual-energy CT angiography determined with virtual monoenergetic imaging. , 2014, Academic radiology.

[2]  Shuai Leng,et al.  Dual-energy CT-based monochromatic imaging. , 2012, AJR. American journal of roentgenology.

[3]  Martin Sedlmair,et al.  Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media , 2014, Investigative radiology.

[4]  B. Siewert,et al.  Split-bolus spectral multidetector CT of the pancreas: assessment of radiation dose and tumor conspicuity. , 2013, Radiology.

[5]  L L Berland,et al.  Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast. , 2013, Clinical radiology.

[6]  C. Claussen,et al.  Assessment of the Hepatic Veins in Poor Contrast Conditions using Dual Energy CT: Evaluation of a Novel Monoenergetic Extrapolation Software Algorithm , 2014, Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren.

[7]  Hans-Peter Meinzer,et al.  Value of three-dimensional reconstructions in pancreatic carcinoma using multidetector CT: initial results. , 2009, World journal of gastroenterology.

[8]  I. Francis Pancreatic adenocarcinoma: diagnosis and staging using multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI) , 2007, Cancer imaging : the official publication of the International Cancer Imaging Society.

[9]  Gaofeng Shi,et al.  Quantitative analysis of the dual-energy CT virtual spectral curve for focal liver lesions characterization. , 2014, European journal of radiology.

[10]  Janet M. Busey,et al.  Dual-energy liver CT: effect of monochromatic imaging on lesion detection, conspicuity, and contrast-to-noise ratio of hypervascular lesions on late arterial phase. , 2014, AJR. American journal of roentgenology.

[11]  R. Pozzi Mucelli,et al.  Comparison between CT and CEUS in the Diagnosis of Pancreatic Adenocarcinoma , 2012, Ultraschall in der Medizin.

[12]  M. Kanematsu,et al.  CT of the pancreas: comparison of anatomic structure depiction, image quality, and radiation exposure between 320-detector volumetric images and 64-detector helical images. , 2011, Radiology.

[13]  S. Schoenberg,et al.  Objective and subjective image quality of liver parenchyma and hepatic metastases with virtual monoenergetic dual-source dual-energy CT reconstructions: an analysis in patients with gastrointestinal stromal tumor. , 2014, Academic radiology.

[14]  A. Abioye,et al.  Pancreatic carcinoma. , 2020, Journal of the National Medical Association.

[15]  S. Schoenberg,et al.  Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography. , 2014, European journal of radiology.

[16]  Julian L Wichmann,et al.  Virtual Monoenergetic Dual-Energy Computed Tomography: Optimization of Kiloelectron Volt Settings in Head and Neck Cancer , 2014, Investigative radiology.

[17]  H. Alkadhi,et al.  Monoenergetic computed tomography reconstructions reduce beam hardening artifacts from dental restorations , 2013, Forensic Science, Medicine, and Pathology.

[18]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[19]  Wolfgang Schima,et al.  Pancreatic adenocarcinoma , 2006, European Radiology.

[20]  D. Morgan,et al.  Multireader evaluation of lesion conspicuity in small pancreatic adenocarcinomas: complimentary value of iodine material density and low keV simulated monoenergetic images using multiphasic rapid kVp-switching dual energy CT , 2015, Abdominal Imaging.

[21]  Bond-Smith Giles,et al.  Only women with symptoms need to have their breast implants removed, says government , 2012 .