Space charge measurement in XLPE cable insulation under high field

Space charge distribution was measured applying an electric field of over 1 MV/cm to 3-mm thick XLPE cable insulation. Under a high field, hetero charges were formed soon after voltage application, followed by an injection from the cathode. Then intermittent injections of charge packet from the anode took place. The space charge distribution kept changing without becoming stabilized. A simulation was done assuming hysteresis of the injection characteristics due to instability near the anode.

[1]  T. Takada,et al.  Pulsed electro-acoustic method for measurement of space charge distribution in power cables under both DC and AC electric fields , 1993 .

[2]  N. Hozumi,et al.  Space charge distribution measurement in a long size XLPE cable using the pulsed electroacoustic method , 1992, Conference Record of the 1992 IEEE International Symposium on Electrical Insulation.

[3]  J. Lewiner,et al.  Determination of space charge distributions in polyethylene samples submitted to 120 kV DC voltage , 1990, Annual Conference on Electrical Insulation and Dielectric Phenomena.

[4]  H. Zeller,et al.  Breakdown and Prebreakdown Phenomena in Solid Dielectrics , 1987, IEEE Transactions on Electrical Insulation.

[5]  J. O'dwyer The Effect of Collision-Ionization Space-Charge on High Field Conduction in Solids , 1980, IEEE Transactions on Electrical Insulation.

[6]  M. Lampert,et al.  Current injection in solids , 1970 .