Blood pressure measuring devices: recommendations of the European Society of Hypertension

There is a large market for blood pressure measuring devices not only in clinical medicine but also among the public where the demand for self measurement of blood pressure is growing rapidly. For consumers, whether medical or lay, accuracy should be of prime importance when selecting a device to measure blood pressure. However, most devices have not been evaluated for accuracy independently using the two most widely used protocols: the British Hypertension Society (BHS) protocol and the standard set by the US Association for the Advancement of Medical Instrumentation (AAMI). 1 2 The Working Group on Blood Pressure Monitoring of the European Society of Hypertension has decided to review blood pressure measuring devices regularly to guide purchasers.3 For this first report devices for which there is published evidence of independent validation using these protocols have been surveyed. Because most blood pressure devices have not been independently validated, only a fraction of the many devices available have been surveyed. Devices that have been validated recently for which results have not yet been published were not included, but this shortcoming should be addressed in future. #### Summary points Two manual sphygmomanometers have been validated, one is recommended Five devices for clinical use in hospitals have been validated, two are recommended 23 devices for self measurement of blood pressure have been validated, five are recommended 24 devices for ambulatory measurement of blood pressure have been validated, 16 are recommended Validations and recommendations will be updated on the BMJ 's website ### Validation standards In 1987, the American Association for the Advancement of Medical Instrumentation published a standard for sphygmomanometers which included a protocol for evaluating the accuracy of devices.4 In 1990 a protocol was devised by the British Hypertension Society.5 Both protocols have since been revised. 1 2 Since the two protocols can be reconciled the …

[1]  F. Mee,et al.  Accuracy of the Del Mar Avionics Pressurometer IV determined by the British Hypertension Society protocol. , 1991, Journal of hypertension.

[2]  S. Brennecke,et al.  Ambulatory blood pressure monitoring in pregnancy. , 1998, Obstetrical & gynecological survey.

[3]  M Di Rienzo,et al.  Estimation of blood pressure variability from 24-hour ambulatory finger blood pressure. , 1998, Hypertension.

[4]  C. Small,et al.  Survey of automated noninvasive blood pressure monitors. , 1994, Journal of clinical engineering.

[5]  N. Atkins,et al.  A comparison of the British Hypertension Society and Association for the Advancement of Medical Instrumentation protocols for validating blood pressure measuring devices: can the two be reconciled? , 1994, Journal of hypertension.

[6]  E. O’Brien Proposals for simplifying the validation protocols of the British Hypertension Society and the Association for the Advancement of Medical Instrumentation. , 2000, Blood pressure monitoring.

[7]  O'brien Automated blood pressure measurement: state of the market in 1998 and the need for an international validation protocol for blood pressure measuring devices. , 1998, Blood pressure monitoring.

[8]  E. O'Brien The Working Group on Blood Pressure Monitoring of the European Society of Hypertension. , 2003, Blood pressure monitoring.

[9]  G. Parati,et al.  Performance of the AM-5600 blood pressure monitor: comparison with ambulatory intra-arterial pressure. , 1997, Journal of applied physiology.

[10]  R. Córdoba,et al.  Validación de un monitor de automedida de la presión arterial: OMRON-HM 722C , 1997 .

[11]  A. Peixoto,et al.  Validation of the SpaceLabs 90207 ambulatory blood pressure device for hemodialysis patients. , 1999, Blood pressure monitoring.

[12]  T. Pickering,et al.  Recommendations for the use of home (self) and ambulatory blood pressure monitoring. American Society of Hypertension Ad Hoc Panel. , 1996, American journal of hypertension.

[13]  A. Coats,et al.  Accuracy of the Omron HEM 706 portable monitor for home measurement of blood pressure. , 1994, Journal of human hypertension.

[14]  F. Mee,et al.  Use and interpretation of ambulatory blood pressure monitoring: recommendations of the British Hypertension Society , 2000, BMJ : British Medical Journal.

[15]  Y. Imai,et al.  The accuracy and performance of the A&D TM 2421, a new ambulatory blood pressure monitoring device based on the cuff-oscillometric method and the Korotkoff sound technique. , 1992, American journal of hypertension.

[16]  A. Franx,et al.  COMPARISON OF AN AUSCULTATORY VERSUS AN OSCILLOMETRIC AMBULATORY BLOOD PRESSURE MONITOR IN NORMOTENSIVE, HYPERTENSIVE, AND PREECLAMPTIC PREGNANCY , 1997 .

[17]  F. Mee,et al.  Short report: accuracy of the Dinamap portable monitor, model 8100 determined by the British Hypertension Society protocol. , 1993, Journal of hypertension.

[18]  K. O’malley,et al.  Sphygmomanometers in hospital and family practice: problems and recommendations. , 1982, British medical journal.

[19]  S. Rithalia,et al.  Comparison of oscillometric and intra-arterial blood pressure and pulse measurement. , 1994, Journal of medical engineering & technology.

[20]  Alpert Validation of CAS model 9010 automated blood pressure monitor:children/adult and neonatal studies. , 1996, Blood pressure monitoring.

[21]  T. Dieterle,et al.  Accuracy and 'range of uncertainty' of oscillometric blood pressure monitors around the upper arm and the wrist. , 1998, Blood pressure monitoring.

[22]  S. Cagnoni,et al.  Simultaneous and sequential same-arm measurements in the validation studies of automated blood pressure measuring devices. , 1996, American journal of hypertension.

[23]  F. Mee,et al.  Evaluation of the SpaceLabs 90202 non-invasive ambulatory recorder according to the AAMI Standard and BHS criteria. , 1991, Journal of human hypertension.

[24]  E. O’Brien,et al.  Proceedings from a Consensus Conference on Self-Blood Pressure Measurement. Devices and validation. , 2000, Blood pressure monitoring.

[25]  G. Parati,et al.  Finapres tracking of systolic pressure and baroreflex sensitivity improved by waveform filtering. , 1996, Journal of hypertension.

[26]  F. Mee,et al.  Evaluation of the Profilomat II ambulatory blood pressure system according to the protocols of the British Hypertension Society and the Association for the Advancement of Medical Instrumentation. , 1998, Blood pressure monitoring.

[27]  F. Mee,et al.  Accuracy of the Novacor DIASYS 200 determined by the British Hypertension Society protocol. , 1991, Journal of hypertension.

[28]  A. Lever,et al.  Mechanisms by which the Hawksley random zero sphygmomanometer underestimates blood pressure and produces a non-random distribution of RZ values , 1997, Journal of Human Hypertension.

[29]  E. O’Brien,et al.  State of the market. A review of ambulatory blood pressure monitoring devices. , 1995, Hypertension.

[30]  A. Shennan,et al.  Oscillometric blood pressure measurements in severe pre‐eclampsia: validation of the SpaceLabs 90207 , 1996, British journal of obstetrics and gynaecology.

[31]  C. Belsha,et al.  Accuracy of the SpaceLabs 90207 ambulatory blood pressure monitor in children and adolescents. , 1996, Blood pressure monitoring.

[32]  F. Mee,et al.  Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society protocol. , 1991, Journal of hypertension.

[33]  J. Baguet,et al.  [Evaluation of the ambulatory blood pressure monitor SAVE 33 model 2]. , 1999, Archives des maladies du coeur et des vaisseaux.

[34]  F. Mee,et al.  Accuracy of the SpaceLabs 90207 ambulatory blood pressure measuring system in normotensive pregnant women determined by the British Hypertension Society protocol , 1993, Journal of hypertension. Supplement : official journal of the International Society of Hypertension.

[35]  F. Mee,et al.  Evaluation of blood pressure measuring devices. , 1993, Clinical and experimental hypertension.

[36]  F. Mee,et al.  Evaluation of the Schiller BR-102 ambulatory blood pressure system according to the protocols of the British Hypertension Society and the Association for the Advancement of Medical Instrumentation. , 1999, Blood pressure monitoring.

[37]  K. Ng Automated noninvasive blood pressure measurement. , 1995, Intensive care world.

[38]  W. White,et al.  Multicenter assessment of the QuietTrak ambulatory blood pressure recorder according to the 1992 AAMI guidelines. , 1994, American journal of hypertension.

[39]  White,et al.  Evaluation of the Datascope Accutorr Plus according to the recommendations of the Association for the Advancement of Medical Instrumentation. , 1997, Blood pressure monitoring.

[40]  E van der Does,et al.  Accuracy of an oscillometric automatic blood pressure device: the Omron HEM403C. , 1995, Journal of human hypertension.

[41]  Baumgart,et al.  Accuracy of the SpaceLabs Medical 90217 ambulatory blood pressure monitor. , 1998, Blood pressure monitoring.

[42]  Ng Kg Automated noninvasive blood pressure measurement. , 1995 .

[43]  A. Shennan,et al.  Validation of the Welch Allyn Quiettrak Ambulatory Blood Pressure Monitor in Pregnancy , 1996 .

[44]  Iqbal,et al.  Validation of the SpaceLabs 90207 automatic non-invasive blood pressure monitor in elderly subjects. , 1996, Blood pressure monitoring.

[45]  A. Dunai,et al.  Evaluation of Meditech ABPM-04 ambulatory blood pressure measuring device according to the British Hypertension Society protocol. , 1998, Blood pressure monitoring.

[46]  A M Pirie,et al.  Oscillometric blood pressure measurements in severe pre‐eclampsia: validation of SpaceLabs 90207 , 1996, British journal of obstetrics and gynaecology.

[47]  H. Sparks,et al.  Comparison of the Omron HEM-713C automated blood pressure monitor with a standard ausculatory method using a mercury manometer. , 1996, The Central African journal of medicine.

[48]  B. Kirby,et al.  Accutracker II (version 30/23) ambulatory blood pressure monitor: clinical validation using the British Hypertension Society and Association for the Advancement of Medical Instrumentation standards , 1993, Journal of hypertension.

[49]  P. Palatini,et al.  Validation of the A&D TM-2430 device for ambulatory blood pressure monitoring and evaluation of performance according to subjects' characteristics. , 1998, Blood pressure monitoring.

[50]  C. Goodman Association for the Advancement of Medical Instrumentation , 1988 .

[51]  R B Haynes,et al.  Canadian hypertension society guidelines for ambulatory blood pressure monitoring. , 1999, American journal of hypertension.

[52]  F. Mee,et al.  Short report: accuracy of the Profilomat ambulatory blood pressure measuring system determined by the British Hypertension Society Protocol. , 1992, Journal of hypertension.

[53]  F. Mee,et al.  Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Nissei DS-175. , 1996, Blood pressure monitoring.

[54]  Modesti,et al.  Clinical evaluation of the QuietTrak blood pressure recorder according to the protocol of the British Hypertension Society. , 1996, Blood pressure monitoring.

[55]  O'brien,et al.  Accuracy of the Dinamap Portable Monitor, model 8100: a review of the evidence for accuracy. , 1997, Blood pressure monitoring.

[56]  O. Hanon,et al.  Validation of two devices for self-measurement of blood pressure by elderly patients according to the revised British Hypertension Society protocol: the Omron HEM-722C and HEM-735C. , 1999, Blood pressure monitoring.

[57]  White,et al.  Evaluation of the efficacy of the Omron HEM-737 IntelliSense device for use on adults according to the recommendations of the Association for the Advancement of Medical Instrumentation. , 1998, Blood pressure monitoring.

[58]  E. O’Brien,et al.  The British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. , 1990, Journal of hypertension.

[59]  Zorn,et al.  Validation of an automated arterial tonometry monitor using Association for the Advancement of Medical Instrumentation standards. , 1997, Blood pressure monitoring.

[60]  F. Mee,et al.  Accuracy of the Takeda TM-2420/TM-2020 determined by the British Hypertension Society protocol. , 1991, Journal of hypertension.

[61]  I. Kuwajima,et al.  The accuracy and clinical performance of a new compact ambulatory blood pressure monitoring device, the ES-H531. , 1998, American journal of hypertension.

[62]  Eckert,et al.  Validation of the OMRON R3 blood pressure self-measuring device through simultaneous comparative invasive measurements according to protocol 58130 of the German Institute for Validation. , 1997, Blood pressure monitoring.

[63]  F. Mee,et al.  Short report: accuracy of the CH-Druck/Pressure Scan ERKA ambulatory blood pressure measuring system determined by the British Hypertension Society Protocol. , 1992, Journal of hypertension.

[64]  G. Germanó,et al.  Evaluation of a new ambulatory blood pressure device. , 1998, American journal of hypertension.

[65]  Steven Vine Validation of the SpaceLabs 90207 ambulatory blood pressure monitor for use in pregnancy , 1993, British journal of obstetrics and gynaecology.

[66]  A W Halligan,et al.  Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia. , 1999, American journal of obstetrics and gynecology.

[67]  W. White,et al.  A multicenter evaluation of the A&D TM-2420 ambulatory blood pressure recorder. , 1991, American journal of hypertension.

[68]  S. A. Butskii Measuring devices , 1958 .

[69]  V. Burke,et al.  COMPARISON OF OSCILLOMETRIC BLOOD PRESSURE MEASUREMENTS AT THE WRIST WITH AN UPPER‐ARM AUSCULTATORY MERCURY SPHYGMOMANOMETER , 1999, Clinical and experimental pharmacology & physiology.

[70]  C. Wren,et al.  Validation of the Takeda 2421 ambulatory blood pressure monitor in children. , 1998, Journal of medical engineering & technology.

[71]  F. Mee,et al.  Inaccuracy of seven popular sphygmomanometers for home measurement of blood pressure. , 1990, Journal of hypertension.

[72]  F. Mee,et al.  Inaccuracy of the Hawksley random zero sphygmomanometer , 1990, The Lancet.