Heterogeneous Electrochemical Aptamer-Based Sensor Surfaces for Controlled Sensor Response.

Structure-switching sensors utilize recognition elements that undergo a conformation change upon target binding that is converted into a quantitative signal. Electrochemical, aptamer-based sensors achieve detection of analytes through a conformation change in an electrode-bound, oligonucleotide aptamer by measuring changes in electron transfer efficiencies. The analytical performance of these sensors is related to the magnitude of the conformation change of the aptamer. The goal of the present work is to develop a general method to predictably tune the analytical performance (sensitivity and linear range) of electrochemical, aptamer-based sensors by utilizing a mixture of rationally designed aptamer sequences that are specific for the same target but with different affinities on the same electrode surface. To demonstrate control over sensor performance, we developed heterogeneous sensors for two representative small molecule targets (adenosine triphosphate and tobramycin). We demonstrate that mixtures of modified sequences can be used to tune the affinity, dynamic range, and sensitivity of the resulting sensors predicted by a bi-Langmuir-type isotherm.

[1]  R. Lai,et al.  Effect of signaling probe conformation on sensor performance of a displacement-based electrochemical DNA sensor. , 2013, Analytical chemistry.

[2]  Kevin W Plaxco,et al.  Re-engineering electrochemical biosensors to narrow or extend their useful dynamic range. , 2012, Angewandte Chemie.

[3]  Arica A Lubin,et al.  Optimization of electrochemical aptamer-based sensors via optimization of probe packing density and surface chemistry. , 2008, Langmuir : the ACS journal of surfaces and colloids.

[4]  A. Heeger,et al.  An electronic, aptamer-based small-molecule sensor for the rapid, label-free detection of cocaine in adulterated samples and biological fluids. , 2006, Journal of the American Chemical Society.

[5]  Kevin W Plaxco,et al.  Reagentless measurement of aminoglycoside antibiotics in blood serum via an electrochemical, ribonucleic acid aptamer-based biosensor. , 2010, Analytical chemistry.

[6]  Kevin W Plaxco,et al.  Comparing the properties of electrochemical-based DNA sensors employing different redox tags. , 2009, Analytical chemistry.

[7]  Dai-Wen Pang,et al.  Aptamer biosensor based on fluorescence resonance energy transfer from upconverting phosphors to carbon nanoparticles for thrombin detection in human plasma. , 2011, Analytical chemistry.

[8]  Ying Liu,et al.  Aptamer-based electrochemical biosensor for interferon gamma detection. , 2010, Analytical chemistry.

[9]  D. Patel,et al.  Adaptive recognition by nucleic acid aptamers. , 2000, Science.

[10]  E. Ferapontova,et al.  An RNA aptamer-based electrochemical biosensor for detection of theophylline in serum. , 2008, Journal of the American Chemical Society.

[11]  Kevin W Plaxco,et al.  Engineering biosensors with extended, narrowed, or arbitrarily edited dynamic range. , 2012, Journal of the American Chemical Society.

[12]  Hua-Zhong Yu,et al.  Design and testing of aptamer-based electrochemical biosensors for proteins and small molecules. , 2009, Bioelectrochemistry.

[13]  Kevin W Plaxco,et al.  Re-engineering aptamers to support reagentless, self-reporting electrochemical sensors. , 2010, The Analyst.

[14]  A. Heeger,et al.  Label-free electronic detection of thrombin in blood serum by using an aptamer-based sensor. , 2005, Angewandte Chemie.

[15]  Kevin W Plaxco,et al.  Aptamer-based electrochemical detection of picomolar platelet-derived growth factor directly in blood serum. , 2007, Analytical chemistry.

[16]  M. Stojanović,et al.  Aptamer-based folding fluorescent sensor for cocaine. , 2001, Journal of the American Chemical Society.

[17]  Ying Liu,et al.  Simultaneous detection of cell-secreted TNF-α and IFN-γ using micropatterned aptamer-modified electrodes. , 2012, Biomaterials.

[18]  Ryan J. White,et al.  Enhancing the analytical performance of electrochemical RNA aptamer-based sensors for sensitive detection of aminoglycoside antibiotics. , 2014, Analytical chemistry.

[19]  Kevin W Plaxco,et al.  On the Signaling of Electrochemical Aptamer-Based Sensors: Collision- and Folding-Based Mechanisms. , 2009, Electroanalysis.

[20]  Kurt V. Gothelf,et al.  Optimization of the Electrochemical RNA‐Aptamer Based Biosensor for Theophylline by Using a Methylene Blue Redox Label , 2009 .

[21]  Kevin W Plaxco,et al.  Preparation of electrode-immobilized, redox-modified oligonucleotides for electrochemical DNA and aptamer-based sensing , 2007, Nature Protocols.

[22]  S. Baxter,et al.  Characterization of the heterogeneous binding site affinity distributions in molecularly imprinted polymers. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[23]  Cuisong Zhou,et al.  Detection of oncoprotein platelet-derived growth factor using a fluorescent signaling complex of an aptamer and TOTO , 2006, Analytical and bioanalytical chemistry.

[24]  Ryan J. White,et al.  The Current and Future Role of Aptamers in Electroanalysis , 2014 .

[25]  A. Heeger,et al.  Effect of molecular crowding on the response of an electrochemical DNA sensor. , 2007, Langmuir : the ACS journal of surfaces and colloids.

[26]  Jyun Yoshizumi,et al.  Target-induced strand release (TISR) from aptamer-DNA duplex: a general strategy for electronic detection of biomolecules ranging from a small molecule to a large protein. , 2008, The Analyst.

[27]  Arica A Lubin,et al.  Continuous, real-time monitoring of cocaine in undiluted blood serum via a microfluidic, electrochemical aptamer-based sensor. , 2009, Journal of the American Chemical Society.

[28]  R. Rando,et al.  Specific binding of aminoglycoside antibiotics to RNA. , 1995, Chemistry & biology.

[29]  Kurt V Gothelf,et al.  Effect of serum on an RNA aptamer-based electrochemical sensor for theophylline. , 2009, Langmuir : the ACS journal of surfaces and colloids.

[30]  Ciara K O'Sullivan,et al.  Aptamer conformational switch as sensitive electrochemical biosensor for potassium ion recognition. , 2006, Chemical communications.

[31]  J. Szostak,et al.  A DNA aptamer that binds adenosine and ATP. , 1995, Biochemistry.