MRI-guided breast biopsy: influence of choice of vacuum biopsy system on the mode of biopsy of MRI-only suspicious breast lesions.

OBJECTIVE The purpose of this study was to evaluate two systems of MRI-guided vacuum-assisted biopsy and to investigate the influence of the choice of system on the choice of biopsy mode in the care of patients with lesions found only at MRI. MATERIALS AND METHODS Over a period of 3 years, a total 349 patients underwent MRI-guided tissue sampling of 475 lesions found only at MRI. The lesions were sampled by needle localization plus excisional biopsy or by vacuum-assisted biopsy. Two different systems were used for MRI-guided vacuum-assisted biopsy. During the first half of the study period, a handheld system was used, and during the second half, a console system was used. The procedural advantages and disadvantages, size of lesions biopsied, and time needed for vacuum-assisted biopsy were recorded. The distribution of the type of intervention (needle localization or vacuum-assisted biopsy) used to manage MRI-only lesions during the two study periods also was assessed. RESULTS The average diameter of lesions sampled with vacuum-assisted biopsy was 19.2 mm with the handheld system and 10.4 mm with the console system (p < 0.039). The average biopsy time was 69 minutes for the handheld system and 39 minutes for the console system (p < 0.005). Of the total of 170 MRI-only lesions biopsied with the handheld system, 121 (71%) were sampled by localization and 49 (29%) by vacuum-assisted biopsy. Of the total 305 MRI-only lesions biopsied with the console system, 38 (12%) were sampled by localization and 267 (88%) by vacuum-assisted biopsy. CONCLUSION Because of the procedural advantages of use of the console-based system, smaller lesions were biopsied in less time and with higher operator confidence. This result translated into a major shift in the care of patients with MRI-only lesions away from lesion localization toward increased use of MRI-guided vacuum-assisted biopsy.

[1]  H. Sittek,et al.  Magnetic resonance‐guided, vacuum‐assisted breast biopsy , 2006, Cancer.

[2]  C. Kuhl Current status of breast MR imaging. Part 2. Clinical applications. , 2007, Radiology.

[3]  Mitchell D Schnall,et al.  MR imaging-guided 9-gauge vacuum-assisted core-needle breast biopsy: initial experience. , 2006, Radiology.

[4]  Constance D Lehman,et al.  MRI-guided breast biopsy: clinical experience with 14-gauge stainless steel core biopsy needle. , 2004, AJR. American journal of roentgenology.

[5]  Mitchell D Schnall,et al.  Outcome of MRI-guided breast biopsy. , 2008, AJR. American journal of roentgenology.

[6]  M. J. Vendrell Outcome of MRI-Guided Breast Biopsy , 2009 .

[7]  K. T. Moesta,et al.  Magnetic resonance-guided biopsy of suspicious breast lesions with a handheld vacuum biopsy device , 2006, Acta radiologica.

[8]  Elizabeth A Morris,et al.  Diagnostic breast MR imaging: current status and future directions. , 2010, Magnetic resonance imaging clinics of North America.

[9]  S. Heywang-Köbrunner,et al.  MR-guided interventional breast procedures considering vacuum biopsy in particular. , 2002, European journal of radiology.

[10]  L. Liberman,et al.  Centennial dissertation. Percutaneous imaging-guided core breast biopsy: state of the art at the millennium. , 2000, AJR. American journal of roentgenology.

[11]  J. Baker,et al.  MRI-guided vacuum-assisted breast biopsy with a handheld portable biopsy system. , 2006, AJR. American journal of roentgenology.

[12]  Simone Schrading,et al.  MRI for diagnosis of pure ductal carcinoma in situ: a prospective observational study , 2007, The Lancet.

[13]  E. Morris,et al.  Magnetic Resonance Imaging-guided Breast Biopsies: Tips and Tricks , 2011, Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes.

[14]  E Grabbe,et al.  MR-guided biopsy of suspect breast lesions with a simple stereotaxic add-on-device for surface coils. , 1994, Radiology.

[15]  S. Patterson Image-guided percutaneous breast biopsies , 2011 .

[16]  L. Liberman,et al.  MRI-guided 9-gauge vacuum-assisted breast biopsy: initial clinical experience. , 2005, AJR. American journal of roentgenology.

[17]  C K Kuhl,et al.  Interventional breast MR imaging: clinical use of a stereotactic localization and biopsy device. , 1997, Radiology.

[18]  European quadricentric evaluation of a breast MR biopsy and localization device: technical improvements based on phase-I evaluation , 2002, European Radiology.

[19]  Jessica W T Leung,et al.  Utility of second-look ultrasound in the evaluation of MRI-detected breast lesions. , 2011, Seminars in roentgenology.

[20]  C K Kuhl,et al.  MR imaging--guided large-core (14-gauge) needle biopsy of small lesions visible at breast MR imaging alone. , 2001, Radiology.

[21]  Constance D Lehman,et al.  Clinical experience with MRI-guided vacuum-assisted breast biopsy. , 2005, AJR. American journal of roentgenology.

[22]  F. Sardanelli Additional findings at preoperative MRI: a simple golden rule for a complex problem? , 2010, Breast Cancer Research and Treatment.

[23]  R. Mann,et al.  MR-guided breast biopsy at 3T: diagnostic yield of large core needle biopsy compared with vacuum-assisted biopsy , 2011, European Radiology.

[24]  C. Lehman,et al.  MR imaging-guided breast biopsy using a coaxial technique with a 14-gauge stainless steel core biopsy needle and a titanium sheath. , 2003, AJR. American journal of roentgenology.