Multi-Transmit Beam Forming for Fast Cardiac Imaging—Experimental Validation and In Vivo Application

High frame rate (HFR) echocardiography may be of benefit for functional analysis of the heart. In current clinical equipment, HFR is obtained using multi-line acquisition (MLA) which typically requires broadening of transmit beams. As this may result in a significant degradation of spatial resolution and signal-to-noise ratio (SNR), the capacity of MLA to obtain high quality HFR images remains limited. As an alternative, we have demonstrated by computer simulation that simultaneously transmitting multiple focused beams into different directions [multi-line transmit (MLT)], can increase the frame rate without significantly compromising the spatial resolution or SNR. This study aimed to experimentally verify these theoretical predictions both in vitro and in vivo to demonstrate, for the first time, that cardiac MLT imaging is feasible. Hereto, the ultrasound advanced open platform, equipped with a 2.0 MHz phased array, was programmed to interleave MLT and conventional single line transmit (SLT) beam forming. Using these two beam forming methods, images of phantoms and healthy volunteers were acquired and investigated both qualitatively and quantitatively. The results confirmed our simulations that image quality of a 4MLT imaging system with a Tukey apodization scheme is very competitive to that of SLT while providing a 4 times higher frame rate. It is also demonstrated that MLT can be combined with MLA to provide images at 12-to 16-fold frame rate (about 340-450 Hz) without significantly compromising spatial resolution and SNR. This is thus the first study to demonstrate that this new ultrasound imaging paradigm is viable which could have significant impact on future cardiac ultrasound systems.

[1]  O T von Ramm,et al.  Explososcan: A Parallel Processing Technique For High Speed Ultrasound Imaging With Linear Phased Arrays , 1985, Medical Imaging.

[2]  H. Kanai Propagation of vibration caused by electrical excitation in the normal human heart. , 2009, Ultrasound in medicine & biology.

[3]  Hiroshi Kanai,et al.  High-frame-rate echocardiography using diverging transmit beams and parallel receive beamforming , 2011, Journal of Medical Ultrasonics.

[4]  Jan D'hooge,et al.  Fast three-dimensional ultrasound cardiac imaging using multi-transmit beam forming: A simulation study , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[5]  K. Kristoffersen,et al.  Parallel beamforming using synthetic transmit beams , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Piero Tortoli,et al.  Implementation of parallel transmit beamforming using orthogonal frequency division multiplexing-achievable resolution and interbeam interference , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[7]  Maja Cikes,et al.  Plane wave imaging for cardiac motion estimation at high temporal resolution: A feasibility study in-vivo , 2012, 2012 IEEE International Ultrasonics Symposium.

[8]  A. Drukarev,et al.  Beam transformation techinques for ultrasonic medical imaging , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  T. Misaridis,et al.  Use of modulated excitation signals in medical ultrasound. Part III: high frame rate imaging , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  P. Tortoli,et al.  Multichannel FPGA-based arbitrary waveform generator for medical ultrasound , 2007 .

[11]  P. Tortoli,et al.  A high performance board for acquisition of 64-channel ultrasound RF data , 2012, 2012 IEEE International Ultrasonics Symposium.

[12]  Jan D'hooge,et al.  Multi-transmit beam forming for fast cardiac imaging-a simulation study , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[13]  L. Demi,et al.  Parallel transmit beamforming using orthogonal frequency division multiplexing applied to harmonic Imaging-A feasibility study , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  H. Torp,et al.  Multi-line transmission in 3-D with reduced crosstalk artifacts: a proof of concept study , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[15]  Hon Fai Choi,et al.  Comparison of conventional parallel beamforming with plane wave and diverging wave imaging for cardiac applications: a simulation study , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  S.W. Smith,et al.  High-speed ultrasound volumetric imaging system. II. Parallel processing and image display , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  Raoul Mallart,et al.  Improved imaging rate through simultaneous transmission of several ultrasound beams , 1992, SPIE Optics + Photonics.

[18]  Thomas Deffieux,et al.  Quantitative assessment of breast lesion viscoelasticity: initial clinical results using supersonic shear imaging. , 2008, Ultrasound in medicine & biology.

[19]  M. Fink,et al.  Quantitative assessment of arterial wall biomechanical properties using shear wave imaging. , 2010, Ultrasound in medicine & biology.

[20]  Mathieu Couade,et al.  In Vivo Quantitative Mapping of Myocardial Stiffening and Transmural Anisotropy During the Cardiac Cycle , 2011, IEEE Transactions on Medical Imaging.

[21]  M. Fink,et al.  Quantitative viscoelasticity mapping of human liver using supersonic shear imaging: preliminary in vivo feasibility study. , 2009, Ultrasound in medicine & biology.

[22]  A. Dallai,et al.  ULA-OP: an advanced open platform for ultrasound research , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  K. Thomenius,et al.  Accelerated focused ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  M. Fink,et al.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  A. Dallai,et al.  A reconfigurable and programmable FPGA-based system for nonstandard ultrasound methods , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.