Sparse regularization for EIT reconstruction incorporating structural information derived from medical imaging

Electrical impedance tomography (EIT) reconstructs the conductivity distribution of a domain using electrical data on its boundary. This is an ill-posed inverse problem usually solved on a finite element mesh. For this article, a special regularization method incorporating structural information of the targeted domain is proposed and evaluated. Structural information was obtained either from computed tomography images or from preliminary EIT reconstructions by a modified k-means clustering. The proposed regularization method integrates this structural information into the reconstruction as a soft constraint preferring sparsity in group level. A first evaluation with Monte Carlo simulations indicated that the proposed solver is more robust to noise and the resulting images show fewer artifacts. This finding is supported by real data analysis. The structure based regularization has the potential to balance structural a priori information with data driven reconstruction. It is robust to noise, reduces artifacts and produces images that reflect anatomy and are thus easier to interpret for physicians.

[1]  Zhanqi Zhao,et al.  Regional ventilation in cystic fibrosis measured by electrical impedance tomography. , 2012, Journal of cystic fibrosis : official journal of the European Cystic Fibrosis Society.

[2]  Jari P. Kaipio,et al.  Sparsity reconstruction in electrical impedance tomography: An experimental evaluation , 2012, J. Comput. Appl. Math..

[3]  P. Maass,et al.  Sparse 3D reconstructions in electrical impedance tomography using real data , 2014 .

[4]  A Biguri,et al.  Tracking boundary movement and exterior shape modelling in lung EIT imaging. , 2015, Physiological measurement.

[5]  Zhanqi Zhao,et al.  Electrical impedance tomography: functional lung imaging on its way to clinical practice? , 2015, Expert review of respiratory medicine.

[6]  Neeraj Sharma,et al.  Automated medical image segmentation techniques , 2010, Journal of medical physics.

[7]  Bo Gong,et al.  A clustering based dual model framework for EIT imaging: first experimental results , 2015 .

[8]  Yonina C. Eldar,et al.  C-HiLasso: A Collaborative Hierarchical Sparse Modeling Framework , 2010, IEEE Transactions on Signal Processing.

[9]  Stephen P. Boyd,et al.  Distributed Optimization and Statistical Learning via the Alternating Direction Method of Multipliers , 2011, Found. Trends Mach. Learn..

[10]  Manuchehr Soleimani,et al.  A fast time-difference inverse solver for 3D EIT with application to lung imaging , 2016, Medical & Biological Engineering & Computing.

[11]  Effat Yahaghi,et al.  An exhaustive criterion for estimating quality of images in electrical impedance tomography with application to clinical imaging , 2013, J. Vis. Commun. Image Represent..

[12]  P D Wolf,et al.  Estimation of tissue resistivities from multiple-electrode impedance measurements. , 1994, Physics in medicine and biology.

[13]  Manuchehr Soleimani,et al.  Electrical impedance tomography imaging using a priori ultrasound data , 2006, Biomedical engineering online.

[14]  Julien Mairal,et al.  Optimization with Sparsity-Inducing Penalties , 2011, Found. Trends Mach. Learn..

[15]  U Baysal,et al.  Use of a priori information in estimating tissue resistivities--a simulation study. , 1998, Physics in medicine and biology.

[16]  M. Soleimani,et al.  Sampling of finite elements for sparse recovery in large scale 3D electrical impedance tomography , 2015, Physiological measurement.

[17]  U Baysal,et al.  Tissue resistivity estimation in the presence of positional and geometrical uncertainties. , 2000, Physics in medicine and biology.

[18]  Stéphane Mallat,et al.  Solving Inverse Problems With Piecewise Linear Estimators: From Gaussian Mixture Models to Structured Sparsity , 2010, IEEE Transactions on Image Processing.

[19]  Knut Möller,et al.  Regional airway obstruction in cystic fibrosis determined by electrical impedance tomography in comparison with high resolution CT , 2013, Physiological measurement.

[20]  Knut Möller,et al.  Individual thorax geometry reduces position and size differences in reconstructed images of electrical impedance tomography. , 2014, Journal of X-ray science and technology.

[21]  William R B Lionheart,et al.  GREIT: a unified approach to 2D linear EIT reconstruction of lung images , 2009, Physiological measurement.

[22]  David S. Holder,et al.  Electrical Impedance Tomography : Methods, History and Applications , 2004 .

[23]  William R B Lionheart,et al.  Uses and abuses of EIDORS: an extensible software base for EIT , 2006, Physiological measurement.