OfficeBP: noninvasive continuous blood pressure monitoring based on PPT in office environment

Blood pressure (BP), as a crucial vital sign of human beings, reflects the physical state of the cardiovascular system. Currently, blood pressure is mainly measured by collecting the changes in pressure in the vessel using cuff-sensors. It is a manual operation and cannot achieve continuous BP monitoring. In this work, we developed OfficeBP, a novel non-intrusive BP monitoring system for a typical office environment. OfficeBP relies on measuring the pulse transit time (PTT) between the pulse propagate from arterial proximal to the distal site on once heartbeat. For calculating the PTT, the user's face and thumb fingertip are regarded as the start and end points respectively. A twin-channel PPG sensing system is presented, that is, the fingertip pulse recording photoplethysmography (PPG) is obtained by a low-cost photoelectric sensor integrated with a mouse. Using image processing the face pulse is acquired by remote-PPG (rPPG) that based on a commercial off-the-shelf camera collecting facial video frames. OfficeBP was evaluated on 11 participants in different working conditions including the external illumination factor and personal internal factors, and achieved RMSE result of diastolic blood pressure 4.81 mmHg, systolic blood pressure 5.35 mmHg, demonstrate the feasibility of the system in an office environment.

[1]  Yuan-Ting Zhang,et al.  Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio , 2016, IEEE Transactions on Biomedical Engineering.

[2]  Shwetak N. Patel,et al.  Seismo: Blood Pressure Monitoring using Built-in Smartphone Accelerometer and Camera , 2018, CHI.

[3]  Survi Kyal,et al.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice , 2015, IEEE Transactions on Biomedical Engineering.

[4]  Sander Stuijk,et al.  Algorithmic Principles of Remote PPG , 2017, IEEE Transactions on Biomedical Engineering.

[5]  Yu Sun,et al.  Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging , 2016, IEEE Transactions on Biomedical Engineering.

[6]  Joseph Finkelstein,et al.  Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera , 2016, Journal of Medical Systems.

[7]  Nigel H. Lovell,et al.  The use of photoplethysmography for assessing hypertension , 2019, npj Digital Medicine.

[8]  R. Light,et al.  Role of Home Blood Pressure Monitoring in Overcoming Therapeutic Inertia and Improving Hypertension Control: A Systematic Review and Meta-Analysis , 2011, Hypertension.

[9]  Sander Stuijk,et al.  Exploiting Spatial Redundancy of Image Sensor for Motion Robust rPPG , 2015, IEEE Transactions on Biomedical Engineering.

[10]  Yang Gao,et al.  CamBP: a camera-based, non-contact blood pressure monitor , 2017, UbiComp/ISWC Adjunct.

[11]  Haiyang Ni,et al.  The Noninvasive Blood Pressure Measurement Based on Facial Images Processing , 2019, IEEE Sensors Journal.