Preliminary experience with the mini-extracorporeal circulation system (Medtronic resting heart system).

A compact cardiopulmonary bypass (CPB) utilized by closed circuit system with minimized priming volume can be a solution to reduce adverse effects of CPB, and the Resting Heart System (RHS; Medtronic, Inc, Minneapolis, MN, USA) is the newest one on the market. We performed CABG with RHS in 10 patients, and report here our preliminary experiences with RHS in comparison with conventional CPB. Twenty patients who underwent isolated CABG were randomized into two groups; RHS group (n=10) with the use of RHS and Conventional group (n=10) with the use of a conventional CPB. There were no significant differences of preoperative patient characteristics in both groups. The mean number of grafts was 2.7+/-0.6 and 2.7+/-0.8 (P=0.38), the mean aortic clamp was 32+/-11 and 35+/-11 min (P=0.35), and CPB times were 68+/-25 and 72+/-24 min (P=0.82) in RHS and Conventional group, respectively. All patients but one had no complications and survived in both groups. One patient in RHS group died suddenly on the 5th postoperative day after uneventful postoperative course. Postoperative leukocyte count at 6 h after the operation and value of the C-reactive protein were 11200+/-2310 and 13300+/-3990/mm(3) (P=0.10) and 44.4+/-9.7 and 65.3+/-18.5 mg/l (P=0.045) in RHS and Conventional group, respectively. CABG operations could be safely performed using the RHS with a comfort level similar to standard CPB.

[1]  C. Tribouilloy,et al.  Aortic valve replacement with the minimal extracorporeal circulation (Jostra MECC System) versus standard cardiopulmonary bypass: a randomized prospective trial. , 2004, The Journal of thoracic and cardiovascular surgery.

[2]  Alan Stein,et al.  Benefits of off-pump bypass on neurologic and clinical morbidity: a prospective randomized trial. , 2003, The Annals of thoracic surgery.

[3]  R. Habib,et al.  Adverse effects of low hematocrit during cardiopulmonary bypass in the adult: should current practice be changed? , 2003, The Journal of thoracic and cardiovascular surgery.

[4]  O. Ponzio,et al.  Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation. , 2002, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[5]  T. Gourlay,et al.  The effect of methanol washing of plasticized polyvinyl chloride on biomaterial-contact-mediated CD11b (mac-1) expression in a rat recirculation model. , 2002, Artificial organs.

[6]  J. Linneweber,et al.  Blood Trauma Induced by Clinically Accepted Oxygenators , 2001, ASAIO journal (1992).

[7]  M. Underwood,et al.  Inflammatory response after coronary revascularization with or without cardiopulmonary bypass. , 2000, The Annals of thoracic surgery.

[8]  R. Shemin,et al.  Effect of anticoagulation protocol on outcome in patients undergoing CABG with heparin-bonded cardiopulmonary bypass circuits. , 1998, The Annals of thoracic surgery.

[9]  P. Everts,et al.  Systemic blood activation with open and closed venous reservoirs. , 1995, The Annals of thoracic surgery.