A 4-wire interface SoC for shared multi-implant power transfer and full-duplex communication

This paper describes a novel system for recovering power and providing full-duplex communication over an AC-coupled 4-wire lead between active implantable devices. The target application requires a single Chest Device be connected to a Brain Implant consisting of multiple identical optrodes that record neural activity and provide closed loop optical stimulation. The interface is integrated within each optrode SoC allowing full-duplex and fully-differential communication based on Manchester encoding. The system features a head-to-chest uplink data rate (1.6 Mbps) that is higher than that of the chest-to-head downlink (100kbps) superimposed on a power carrier. On-chip power management provides an unregulated 5 V DC supply with up to 2.5 mA output current for stimulation, and a regulated 3.3 V with 60 dB PSRR for recording and logic circuits. The circuit has been implemented in a 0.35 μm CMOS technology, occupying 1.4 mm2 silicon area, and requiring a 62.2 μA average current consumption.

[1]  P. E. K. Donaldson,et al.  The Cooper cable: an implantable multiconductor cable for neurological prostheses , 1983, Medical and Biological Engineering and Computing.

[2]  Nicholas G. Hatsopoulos,et al.  Brain-machine interface: Instant neural control of a movement signal , 2002, Nature.

[3]  Shun Bai,et al.  A charge-balanced 4-wire interface for the interconnections of biomedical implants , 2013, 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[4]  Maysam Ghovanloo,et al.  Active High Power Conversion Efficiency Rectifier With Built-In Dual-Mode Back Telemetry in Standard CMOS Technology , 2008, IEEE Transactions on Biomedical Circuits and Systems.

[5]  Giovanni De Micheli,et al.  An implantable bio-micro-system for drug monitoring , 2013, 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[6]  Nigel H. Lovell,et al.  Design of Safe Two-Wire Interface-Driven Chip-Scale Neurostimulator for Visual Prosthesis , 2013, IEEE Journal of Solid-State Circuits.

[7]  V. von Kaenel,et al.  A 4-GHz clock system for a high-performance system-on-a-chip design , 2001 .

[8]  Maysam Ghovanloo,et al.  Fully-Integrated CMOS Power Regulator for Telemetry-Powered Implantable Biomedical Microsystems , 2006, IEEE Custom Integrated Circuits Conference 2006.

[9]  Shun Bai,et al.  A Complete 256-Electrode Retinal Prosthesis Chip , 2014, IEEE Journal of Solid-State Circuits.

[10]  Chih-Wei Chang,et al.  A fully integrated 8-channel closed-loop neural-prosthetic SoC for real-time epileptic seizure control , 2013, 2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers.

[11]  Timothy G. Constandinou,et al.  A CMOS-based neural implantable optrode for optogenetic stimulation and electrical recording , 2015, 2015 IEEE Biomedical Circuits and Systems Conference (BioCAS).