The "Millipede"-More than thousand tips for future AFM storage

We report on a new atomic force microscope (AFM)-based data storage concept called the “Millipede” that has a potentially ultrahigh density, terabit capacity, small form factor, and high data rate. Its potential for ultrahigh storage density has been demonstrated by a new thermomechanical local-probe technique to store and read back data in very thin polymer films. With this new technique, 30–40-nm-sized bit indentations of similar pitch size have been made by a single cantilever/tip in a thin (50-nm) polymethylmethacrylate (PMMA) layer, resulting in a data storage density of 400–500 Gb/in. 2 High data rates are achieved by parallel operation of large two-dimensional (2D) AFM arrays that have been batch-fabricated by silicon surface-micromachining techniques. The very large scale integration (VLSI) of micro/nanomechanical devices (cantilevers/tips) on a single chip leads to the largest and densest 2D array of 32 × 32 (1024) AFM cantilevers with integrated write/read storage functionality ever built. Time-multiplexed electronics control the write/read storage cycles for parallel operation of the Millipede array chip. Initial areal densities of 100–200 Gb/in. 2 have been achieved with the 32 × 32 array chip, which has potential for further improvements. In addition to data storage in polymers or other media, and not excluding magnetics, we envision areas in nanoscale science and technology such as lithography, high-speed/large-scale imaging, molecular and atomic manipulation, and many others in which Millipede may open up new perspectives and opportunities.

[1]  S. M. Sze,et al.  Physics of semiconductor devices , 1969 .

[2]  T. Ravi,et al.  Oxidation sharpening of silicon tips , 1991 .

[3]  D. Rugar,et al.  Thermomechanical writing with an atomic force microscope tip , 1992 .

[4]  Robert C. Barrett,et al.  High-density data storage using proximal probe techniques , 1995, IBM J. Res. Dev..

[5]  E. Grochowski,et al.  Future trends in hard disk drives , 1996 .

[6]  L. Fan,et al.  6-MHz 2-N/m piezoresistive atomic-force microscope cantilevers with INCISIVE tips , 1997 .

[7]  T. Kenny,et al.  Micromachined heaters with 1-/spl mu/s thermal time constants for AFM thermomechanical data storage , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).

[8]  C. Quate,et al.  AUTOMATED PARALLEL HIGH-SPEED ATOMIC FORCE MICROSCOPY , 1998 .

[9]  B. Terris,et al.  Atomic force microscope-based data storage: track servo and wear study , 1998 .

[10]  M. Lutwyche,et al.  Microfabrication and parallel operation of 5/spl times/5 2D AFM cantilever arrays for data storage and imaging , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[11]  W. Häberle,et al.  Ultrahigh density, high-data-rate NEMS-based AFM data storage system , 1999 .

[12]  Ute Drechsler,et al.  Planar micromagnetic X/Y/Z scanner with five degrees of freedom , 1999 .

[13]  B. Terris,et al.  High-density data storage based on the atomic force microscope , 1999, Proc. IEEE.

[14]  Ute Drechsler,et al.  5×5 2D AFM cantilever arrays a first step towards a Terabit storage device , 1999 .

[15]  W. Häberle,et al.  VLSI-NEMS chip for AFM data storage , 1999, Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291).

[16]  David A. Thompson,et al.  The future of magnetic data storage technology , 2000, IBM J. Res. Dev..

[17]  W. Häberle,et al.  Fabrication of a micromachined magnetic X/Y/Z scanner for parallel scanning probe applications , 2000 .

[18]  W. Häberle,et al.  VLSI-NEMS chip for parallel AFM data storage , 2000 .