Comparing strategies for deep astigmatism-based single-molecule localization microscopy

: Single-molecule localization microscopy (SMLM) enables fluorescent microscopy with nanometric resolution. While localizing molecules close to the coverslip is relatively straightforward using high numerical aperture (NA) oil immersion (OI) objectives, optical aberrations impede SMLM deeper in watery samples. Adaptive optics (AO) with a deformable mirror (DM) can be used to correct such aberrations and to induce precise levels of astigmatism to encode the z- position of molecules. Alternatively, the use of water immersion (WI) objectives might be sufficient to limit the most dominant aberrations. Here we compare SMLM at various depths using either WI or OI with or without AO. In addition, we compare the performance of a cylindrical lens and a DM for astigmatism-based z- encoding. We find that OI combined with adaptive optics improves localization precision beyond the performance of WI-based imaging and enables deep ( > 10 µm) 3D localization. in bypass mode. The AO-module consists of 3 lenses and 4 broadband mirrors. The DM itself has a silver coating with a reflectance of 98% at 15 degree incidence. These results in a total transmission of 93% for the AO-module.

[1]  Jonas Ries,et al.  Depth-dependent PSF calibration and aberration correction for 3D single-molecule localization , 2019, bioRxiv.

[2]  A. Akhmanova,et al.  Guided by Light: Optical Control of Microtubule Gliding Assays , 2018, Nano letters.

[3]  Sheng Liu,et al.  Active PSF Shaping and Adaptive Optics Enable Volumetric Localization Microscopy through Brain Sections , 2018, Nature Methods.

[4]  S. Stallinga,et al.  High precision wavefront control in point spread function engineering for single emitter localization. , 2018, Optics express.

[5]  S. Webb,et al.  Characterisation of the effects of optical aberrations in single molecule techniques , 2016, Biomedical optics express.

[6]  Matthew D. Lew,et al.  Correcting field-dependent aberrations with nanoscale accuracy in three-dimensional single-molecule localization microscopy. , 2015, Optica.

[7]  Brian Patton,et al.  Adaptive optics correction of specimen-induced aberrations in single-molecule switching microscopy , 2015 .

[8]  Adam S. Backer,et al.  Optimal point spread function design for 3D imaging. , 2014, Physical review letters.

[9]  Wei Zhang,et al.  Correction of depth-dependent aberrations in 3D single-molecule localization and super-resolution microscopy. , 2014, Optics letters.

[10]  Joerg Bewersdorf,et al.  Optical nanoscopy: from acquisition to analysis. , 2012, Annual review of biomedical engineering.

[11]  Ignacio Izeddin,et al.  PSF shaping using adaptive optics for three-dimensional single-molecule super-resolution imaging and tracking. , 2012, Optics express.

[12]  S. Stallinga,et al.  Accuracy of the gaussian point spread function model in 2D localization microscopy. , 2010, Optics express.

[13]  Samuel J. Lord,et al.  Three-dimensional, single-molecule fluorescence imaging beyond the diffraction limit by using a double-helix point spread function , 2009, Proceedings of the National Academy of Sciences.

[14]  X. Zhuang,et al.  Whole cell 3D STORM reveals interactions between cellular structures with nanometer-scale resolution , 2008, Nature Methods.

[15]  S. Hess,et al.  Three-dimensional sub–100 nm resolution fluorescence microscopy of thick samples , 2008, Nature Methods.

[16]  Mark Bates,et al.  Three-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy , 2008, Science.

[17]  T Wilson,et al.  Specimen‐induced distortions in light microscopy , 2007, Journal of microscopy.

[18]  Michael J Rust,et al.  Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM) , 2006, Nature Methods.

[19]  J. Lippincott-Schwartz,et al.  Imaging Intracellular Fluorescent Proteins at Nanometer Resolution , 2006, Science.

[20]  T. Wilson,et al.  Adaptive aberration correction in a confocal microscope , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[21]  M Rajadhyaksha,et al.  Analysis of spherical aberration of a water immersion objective: application to specimens with refractive indices 1.33–1.40 , 2000, Journal of microscopy.

[22]  R. Noll Zernike polynomials and atmospheric turbulence , 1976 .

[23]  C. Hoogenraad,et al.  Studying neuronal microtubule organization and microtubule-associated proteins using single molecule localization microscopy. , 2016, Methods in cell biology.