Open-Flow Microperfusion of Subcutaneous Adipose Tissue for On-Line Continuous Ex Vivo Measurement of Glucose Concentration

OBJECTIVE To evaluate a novel technique for on-line continuous glucose measurement in subcutaneous adipose tissue, and to investigate its accuracy for detection of hypoglycemia. RESEARCH DESIGN AND METHODS The method combined an open-flow microperfusion of subcutaneous adipose tissue using a double lumen catheter and an extracorporeal sensor cell. An isotonic ion-free solution was perfused through the inner lumen of the catheter, equilibrated with the subcutaneous tissue fluid, and sampled through the outer lumen. The recovery was continuously monitored as the ratio between the measured sampled fluid conductivity and the subcutaneous tissue fluid conductivity (assumed to have a constant value of 1.28 S/m at 25°C). Glucose concentration was calculated on-line from the measured glucose in the sampled fluid and the measured recovery in healthy volunteers during hyperglycemic glucose loads (n = 8), hypoglycemic hyperinsulinemic clamp (n = 6), and a 24-h monitoring period (n = 7). RESULTS Subcutaneous glucose concentrations in the fasting state were 94% of the plasma glucose concentrations in arterialized venous samples. According to the error grid analysis, 96.9% of the on-line measured subcutaneous glucose concentrations during hyperglycemia and 96.3% during hypoglycemia were in accurate or acceptable zones. The mean differences between the measured subcutaneous glucose and the actual plasma glucose concentration were −0.06–3.3 mmol/l (hyperglycemia), and −0.6–1.1 mmol/l (hypoglycemia). CONCLUSIONS By combining open-flow microperfusion, glucose sensor, and conductivity measurement, glucose concentration in the subcutaneous adipose tissue can be monitored on-line, extracorporeally, and continuously without any in vivo calibration, and gives accurate measurements during hyper- and hypoglycemia.

[1]  R. Tannen,et al.  Fluids and electrolytes , 1986 .

[2]  P. Cryer,et al.  Glycemic thresholds for activation of glucose counterregulatory systems are higher than the threshold for symptoms. , 1987, The Journal of clinical investigation.

[3]  P. Jansson,et al.  A microdialysis method allowing characterization of intercellular water space in humans. , 1987, The American journal of physiology.

[4]  P. Vadgama,et al.  Needle enzyme electrodes for biological studies. , 1986, Biosensors.

[5]  R. P. Bell,et al.  Modern Electrochemistry , 1966, Nature.

[6]  R. E. Burgess [Fluids and electrolytes]. , 1965, Hu li za zhi The journal of nursing.

[7]  D. Gough,et al.  Development of the Implantable Glucose Sensor: What Are the Prospects and Why Is It Taking So Long? , 1995, Diabetes.

[8]  D. Gough,et al.  Physiological preparation for studying the response of subcutaneously implanted glucose and oxygen sensors. , 1989, Journal of biomedical engineering.

[9]  C Meyerhoff,et al.  Subcutaneous Glucose Concentration in Humans: Real estimation and continuous monitoring , 1995, Diabetes Care.

[10]  P. Jansson,et al.  An improved method to calculate adipose tissue interstitial substrate recovery for microdialysis studies. , 1994, Life sciences.

[11]  U. Ungerstedt,et al.  Long-term continuous glucose monitoring with microdialysis in ambulatory insulin-dependent diabetic patients , 1993, The Lancet.

[12]  Portable device for continuous fractionated blood sampling and continuous ex vivo blood glucose monitoring. , 1996, Biosensors & bioelectronics.

[13]  P. Kissinger,et al.  Determination of endogenous ions in intercellular fluid using capillary ultrafiltration and microdialysis probes. , 1993, Journal of pharmaceutical and biomedical analysis.

[14]  N F de Rooij,et al.  In-vivo behaviour of hypodermically implanted microfabricated glucose sensors. , 1991, Biosensors & bioelectronics.

[15]  A. M. Albisser,et al.  9 The artificial pancreas , 1977 .

[16]  D. Cox,et al.  Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose , 1987, Diabetes Care.

[17]  Y. Yamasaki,et al.  Closed-Loop Glycemic Control with a Wearable Artificial Endocrine Pancreas Variations in Daily Insulin Requirements to Glycemic Response , 1984, Diabetes.

[18]  P Abel,et al.  Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell. , 1984, Biomedica biochimica acta.

[19]  L. Strindberg,et al.  Validation of the 'internal reference technique' for calibrating microdialysis catheters in situ. , 1995, Acta physiologica Scandinavica.

[20]  U. Ungerstedt,et al.  The ethanol technique of monitoring local blood flow changes in rat skeletal muscle: implications for microdialysis. , 1992, Acta physiologica Scandinavica.

[21]  R N Bergman,et al.  Minimal model analysis of intravenous glucose tolerance test-derived insulin sensitivity in diabetic subjects. , 1990, The Journal of clinical endocrinology and metabolism.

[22]  J. Bülow,et al.  Microdialysis of the interstitial water space in human skin in vivo: quantitative measurement of cutaneous glucose concentrations. , 1992, The Journal of investigative dermatology.

[23]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[24]  W. Tamborlane,et al.  Interstitial fluid concentrations of glycerol, glucose, and amino acids in human quadricep muscle and adipose tissue. Evidence for significant lipolysis in skeletal muscle. , 1995, The Journal of clinical investigation.

[25]  M. Shichiri,et al.  Development of a Miniaturized Glucose Monitoring System by Combining a Needle-Type Glucose Sensor With Microdialysis Sampling Method: Long-term subcutaneous tissue glucose monitoring in ambulatory diabetic patients , 1994, Diabetes Care.

[26]  J. Korf,et al.  Continuous monitoring of glucose with a transcutaneous microdialysis probe , 1992, The Lancet.

[27]  Russell O. Potts,et al.  Measurement of glucose in diabetic subjects using noninvasive transdermal extraction , 1995, Nature Medicine.

[28]  F J Schmidt,et al.  Glucose Concentration in Subcutaneous Extracellular Space , 1993, Diabetes Care.

[29]  P. Jansson,et al.  Characterization by microdialysis of intracellular glucose level in subcutaneous tissue in humans. , 1988, The American journal of physiology.

[30]  G. S. Wilson,et al.  Study and development of multilayer needle-type enzyme-based glucose microsensors. , 1989, Biosensors.

[31]  S. Rössner,et al.  In vivo subcutaneous adipose tissue glucose kinetics after glucose ingestion in obesity and fasting. , 1990, Scandinavian journal of clinical and laboratory investigation.

[32]  P. Jansson,et al.  Glycerol production in subcutaneous adipose tissue in lean and obese humans. , 1992, The Journal of clinical investigation.