Microelectrode miRNA sensors enabled by enzymeless electrochemical signal amplification.

Better detections of circulating microRNAs (miRNAs) as disease biomarkers could advance diseases diagnosis and treatment. Current analysis methods or sensors for research and applications are challenged by the low concentrations and wide dynamic range (from aM to nM) of miRNAs in a physiological sample. Here, we report a one-step label-free electrochemical sensor comprising a triple-stem DNA-redox probe structure on a gold microelectrode. A new signal amplification mechanism without the need of a redox enzyme is introduced. The novel strategy overcomes the fundamental limitations of microelectrode DNA sensors that fail to generate detectable current, which is primarily due to the limited amount of redox probes in response to the target analyte binding. By employing a reductant, tris(2-carboxyethyl) phosphine hydrochloride (TCEP) in the detection buffer solution, each redox molecule on the detection probe is cyclically oxidized at the electrode and reduced by the reductant; thus, the signal is amplified in situ during the detection period. The combined merits in the diagnosis power of cyclic voltammetry and the high sensitivity of pulse voltammetry enable parallel analysis for method validation and optimization previously inaccessible. As such, the detection limit of miRNA-122 was 0.1 fM via direct readout, with a wide detection range from sub fM to nM. The detection time is within minutes, which is a significant improvement over other macroscopic sensors and other relevant techniques such as quantitative reverse transcription polymerase chain reaction (qRT-PCR). The high selectivity of the developed sensors is demonstrated by the discrimination against two most similar family sequences: miR-122-3p present in serum and 2-mismatch synthetic RNA sequence. Interference such as nonspecific adsorption, a common concern in sensor development, is reduced to a negligible amount by adopting a multistep surface modification strategy. Importantly, unlike qRT-PCR, the microelectrochemical sensor offers direct absolute quantitative readout that is amenable to clinical and in-home point-of-care (POC) applications. The sensor design is flexible, capable of being tailored for detection of different miRNAs of interest. Combined with the fact that the sensor was constructed at microscale, the method can be generalized for high throughput detection of miRNA signatures as disease biomarkers.

[1]  Mahmoud Labib,et al.  Protein electrocatalysis for direct sensing of circulating microRNAs. , 2015, Analytical chemistry.

[2]  Shana O Kelley,et al.  Direct electrocatalytic mRNA detection using PNA-nanowire sensors. , 2009, Analytical chemistry.

[3]  Takahiro Ochiya,et al.  Circulating microRNA in body fluid: a new potential biomarker for cancer diagnosis and prognosis , 2010, Cancer science.

[4]  E. Ferapontova,et al.  An RNA aptamer-based electrochemical biosensor for detection of theophylline in serum. , 2008, Journal of the American Chemical Society.

[5]  Sandra B. Munro,et al.  Detection of Cancer with Serum miRNAs on an Oligonucleotide Microarray , 2009, PloS one.

[6]  Christopher Pöhlmann,et al.  Electrochemical detection of microRNAs via gap hybridization assay. , 2010, Analytical chemistry.

[7]  Jonathan Moggs,et al.  Circulating microRNAs as potential markers of human drug‐induced liver injury , 2011, Hepatology.

[8]  Shana O Kelley,et al.  Amplified electrocatalysis at DNA-modified nanowires. , 2005, Nano letters.

[9]  Zhiqiang Gao,et al.  A highly sensitive and specific biosensor for ligation- and PCR-free detection of microRNAs. , 2011, Biosensors & bioelectronics.

[10]  Robert Langer,et al.  Long-Term Stability of Self-Assembled Monolayers in Biological Media , 2003 .

[11]  X. Chen,et al.  Characterization of microRNAs in serum: a novel class of biomarkers for diagnosis of cancer and other diseases , 2008, Cell Research.

[12]  Sota Asaga,et al.  Direct serum assay for microRNA-21 concentrations in early and advanced breast cancer. , 2011, Clinical chemistry.

[13]  Rong Wang,et al.  Identification of Circulating MicroRNAs as Potential Biomarkers for Detecting Acute Myeloid Leukemia , 2013, PloS one.

[14]  Zhiqiang Gao,et al.  Direct labeling microRNA with an electrocatalytic moiety and its application in ultrasensitive microRNA assays. , 2007, Biosensors & bioelectronics.

[15]  L. Blum,et al.  DNA biosensors and microarrays. , 2008, Chemical reviews.

[16]  Hailin Tang,et al.  Direct quantification of microRNA at low picomolar level in sera of glioma patients using a competitive hybridization followed by amplified voltammetric detection. , 2012, Analytical chemistry.

[17]  Bryan R. Cullen,et al.  Viral and cellular messenger RNA targets of viral microRNAs , 2009, Nature.

[18]  Juan Liu,et al.  Noninvasive surface coverage determination of chemically modified conical nanopores that rectify ion transport. , 2012, Analytical chemistry.

[19]  M. Berezovski,et al.  Three-mode electrochemical sensing of ultralow microRNA levels. , 2012, Journal of the American Chemical Society.

[20]  R. Lai,et al.  Fabrication of electrochemical DNA sensors on gold-modified recessed platinum nanoelectrodes. , 2014, Analytical chemistry.

[21]  C. Burge,et al.  The microRNAs of Caenorhabditis elegans. , 2003, Genes & development.

[22]  D. Kolpashchikov,et al.  Four-way junction formation promoting ultrasensitive electrochemical detection of microRNA. , 2013, Analytical chemistry.

[23]  L. Hood,et al.  Circulating microRNAs, potential biomarkers for drug-induced liver injury , 2009, Proceedings of the National Academy of Sciences.

[24]  H. Soh,et al.  An electrochemical sensor for single nucleotide polymorphism detection in serum based on a triple-stem DNA probe. , 2009, Journal of the American Chemical Society.

[25]  Dieter Klein,et al.  Quantification using real-time PCR technology : applications and limitations , 2002 .

[26]  Zhiqiang Gao A highly sensitive electrochemical assay for microRNA expression profiling. , 2012, The Analyst.

[27]  Kevin W Plaxco,et al.  Comparing the properties of electrochemical-based DNA sensors employing different redox tags. , 2009, Analytical chemistry.

[28]  Yongwon Jung,et al.  Two-temperature hybridization for microarray detection of label-free microRNAs with attomole detection and superior specificity. , 2011, Angewandte Chemie.

[29]  R. E. Gyurcsányi,et al.  Electrochemical Detection of miRNAs , 2014 .

[30]  Jingli Yan,et al.  Ultrasensitive quantification of mature microRNAs by real-time PCR based on ligation of a ribonucleotide-modified DNA probe. , 2011, Chemical communications.

[31]  Huangxian Ju,et al.  MicroRNA: function, detection, and bioanalysis. , 2013, Chemical reviews.

[32]  C. Croce,et al.  An oligonucleotide microchip for genome-wide microRNA profiling in human and mouse tissues. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[33]  Yuan Hong Yu,et al.  A microRNA biosensor based on direct chemical ligation and electrochemically amplified detection , 2007 .

[34]  Juan Liu,et al.  Impedance characteristics of amine modified single glass nanopores. , 2010, Analytical chemistry.

[35]  Ryan J. White,et al.  Bench-top method for fabricating glass-sealed nanodisk electrodes, glass nanopore electrodes, and glass nanopore membranes of controlled size. , 2007, Analytical chemistry.

[36]  Ryan J. White,et al.  Achieving Reproducible Performance of Electrochemical, Folding Aptamer-Based Sensors on Microelectrodes: Challenges and Prospects , 2014, Analytical chemistry.

[37]  M. Bakovic,et al.  Choline Transport for Phospholipid Synthesis , 2006 .

[38]  Yue Wang,et al.  Plasma microRNA-122 as a biomarker for viral-, alcohol-, and chemical-related hepatic diseases. , 2010, Clinical chemistry.

[39]  J. Park,et al.  Preparation, characterization, and chemical stability of gold nanoparticles coated with mono-, bis-, and tris-chelating alkanethiols. , 2008, Langmuir.

[40]  Frank D Sistare,et al.  Plasma MicroRNAs as sensitive and specific biomarkers of tissue injury. , 2009, Clinical chemistry.

[41]  C. Perou,et al.  A custom microarray platform for analysis of microRNA gene expression , 2004, Nature Methods.

[42]  C. Burge,et al.  Conserved Seed Pairing, Often Flanked by Adenosines, Indicates that Thousands of Human Genes are MicroRNA Targets , 2005, Cell.

[43]  S. Thorgeirsson,et al.  Loss of miR-122 expression in liver cancer correlates with suppression of the hepatic phenotype and gain of metastatic properties , 2009, Oncogene.

[44]  Kevin W Plaxco,et al.  Exploiting binding-induced changes in probe flexibility for the optimization of electrochemical biosensors. , 2010, Analytical chemistry.

[45]  Yu Liang,et al.  BMC Genomics , 2007 .

[46]  Ariel L. Furst,et al.  Electrocatalysis in DNA Sensors. , 2014, Polyhedron.

[47]  Tanyu Wang,et al.  Quantitation of femtomolar protein levels via direct readout with the electrochemical proximity assay. , 2012, Journal of the American Chemical Society.

[48]  Juan Liu,et al.  Surface charge density determination of single conical nanopores based on normalized ion current rectification. , 2012, Langmuir : the ACS journal of surfaces and colloids.

[49]  Jason H. Moore,et al.  Characterization of microRNA expression levels and their biological correlates in human cancer cell lines. , 2007, Cancer research.