Response method in audiometry.

PURPOSE This study compared the speed, false-alarm rate, and participant preference of different response methods (raising a hand, pushing a response button, and giving an oral response) for measuring pure-tone thresholds. METHOD Thirty female university students with normal hearing participated. Response method order was randomly assigned to 6 different groups. Air-conduction thresholds were measured twice for each response method for each participant in octave intervals between 250 Hz and 8000 Hz. The 2nd threshold measurements were performed on a different day but within 2 weeks of the initial measurement. RESULTS A significant difference was found when comparing the amount of time necessary to complete the test for each response method. On average, it took about 1 min less when using the push-button response than when using hand-raise or verbal response methods. There was also a significant participant preference for using the response button. No significant difference between response method for threshold level and number of false positives was found. CONCLUSION This study supports the use of the response button when measuring auditory thresholds for young adults with normal hearing.

[1]  Antonio Prado Moreno,et al.  Vlerick Leuven Gent Working Paper Series 2003/22 Starting Resource Configurations of Research-based Start-ups and the Interaction with Technology , 2022 .

[2]  Robert S. Schlauch,et al.  Threshold Measurement for Patients with Tinnitus , 1997 .

[3]  S. Arlinger Comparison of ascending and bracketing methods in pure tone audiometry. A multi-laboratory study. , 1979, Scandinavian audiology.

[4]  Guidelines for manual pure-tone threshold audiometry. , 1978, ASHA.

[5]  R S Tyler,et al.  A comparison of manual methods for measuring hearing levels. , 1980, Audiology : official organ of the International Society of Audiology.

[6]  J. Jerger,et al.  Preferred Method For Clinical Determination Of Pure-Tone Thresholds , 1959 .

[7]  S. N. Reger Standardization of pure tone audiometer testing technique. , 1950 .

[8]  J. Jerger,et al.  Studies in impedance audiometry. I. Normal and sensorineural ears. , 1972, Archives of otolaryngology.

[9]  Paul G Shekelle,et al.  Screening and management of adult hearing loss in primary care: clinical applications. , 2003, JAMA.

[10]  J. Harris Optimum threshold crossings and time-window validation in threshold pure-tone computerized audiometry. , 1979, Journal of the Acoustical Society of America.

[11]  T. Hamill,et al.  The relationship of pulsed, continuous, and warble extended-high frequency thresholds. , 1986, Journal of communication disorders.

[12]  Kenneth O. Johnson American Speech and Hearing Association , 1961, Science.

[13]  T. Wiley,et al.  Continuous versus pulsed tones in audiometry. , 2004, American journal of audiology.