Winding Design and Electromagnetic Analysis for a 1250-kVA HTS Transformer

Because high-temperature superconducting (HTS) coils possess low-resistivity, large-current-carrying, and state transition characteristics, the design of HTS transformers is much different from that of conventional ones. The general design of 10.5-kV/1250-kVA HTS transformer is given first. In the electromagnetic design of the 1250-kVA HTS transformer windings via field-circuit coupling simulation, the influence of leakage magnetic field on the critical current of tapes and the circulating current of parallel branches was considered. Moreover, the transient stability of transformer windings combined with superconducting fault current limiter in the HTS power substation is discussed. Based on electromagnetic analysis, the primary and the secondary windings are constructed, and a special transposed method for double pancakes wound with four parallel tapes is proposed. Finally, the current-carrying ability of the primary and the secondary windings is tested in 77 K. Their critical currents are higher than 200 and 3200 A, respectively, which is enough in rated operating condition.

[1]  Qingquan Qiu,et al.  Development of the World's First HTS Power Substation , 2012, IEEE Transactions on Applied Superconductivity.

[2]  S. Mehta US effort on HTS power transformers , 2011 .

[3]  H Kojima,et al.  Progress in Development of Superconducting Fault Current Limiting Transformer (SFCLT) , 2011, IEEE Transactions on Applied Superconductivity.

[4]  H. Mohseni,et al.  Balancing Current Distribution in Parallel Windings of Furnace Transformers Using the Genetic Algorithm , 2010, IEEE Transactions on Magnetics.

[5]  Liye Xiao,et al.  Development of a 630 kVA Three-Phase HTS Transformer With Amorphous Alloy Cores , 2007, IEEE Transactions on Applied Superconductivity.

[6]  Liye Xiao,et al.  Development of a 45 kVA Single-Phase Model HTS Transformer , 2006, IEEE Transactions on Applied Superconductivity.

[7]  G. Long,et al.  Analysis of magnetic field and circulating current for HTS transformer windings , 2005, IEEE Transactions on Applied Superconductivity.

[8]  N. Aversa,et al.  Design and operational testing of a 5/10-MVA HTS utility power transformer , 2005, IEEE Transactions on Applied Superconductivity.

[9]  M. Meinert,et al.  Development of high-temperature superconducting transformers for railway applications , 2003 .

[10]  H Zueger,et al.  630 kVA high temperature superconducting transformer , 1998 .

[11]  K Sato,et al.  Development of a 500 kVA-class oxide-superconducting power transformer operated at liquid-nitrogen temperature , 1998 .

[12]  Qiu Qing,et al.  Research on Optimization Design for Cross Section of Transformer Core Based on Improved Genetic Algorithm , 2004 .