A paradigm for the development and evaluation of novel implant topologies for bone fixation: implant design and fabrication.

The future development of bio-integrated devices will improve the functionality of robotic prosthetic limbs. A critical step in the advancement of bio-integrated prostheses will be establishing long-term, secure fixation to the remnant bone. To overcome limitations associated with contemporary bone-anchored prosthetic limbs, we established a paradigm for developing and fabricating novel orthopedic implants undergoing specified loading. A topology optimization scheme was utilized to generate optimal implant macrostructures that minimize deformations near the bone-implant interface. Variations in implant characteristics and interfacial connectivity were investigated to examine how these variables influence the layout of the optimized implant. For enhanced tissue integration, the optimally designed macroscopic geometry of a titanium (Ti)-alloy implant was further modified by introducing optimized microstructures. The complex geometries of selected implants were successfully fabricated using selective laser sintering (SLS) technology. Fabrication accuracy was assessed by comparing volumes and cross-sectional areas of fabricated implants to CAD data. The error of fabricated volume to CAD design volume was less than 8% and differences in cross sectional areas between SEM images of fabricated implants and corresponding cross sections from CAD design were on average less than 9%. We have demonstrated that this computational design method, combined with solid freeform fabrication techniques, provides a versatile way to develop novel orthopedic implants.

[1]  M. von Walter,et al.  Structural, mechanical and in vitro characterization of individually structured Ti-6Al-4V produced by direct laser forming. , 2006, Biomaterials.

[2]  André Zaoui,et al.  Homogenization techniques for composite media : lectures delivered at the CISM International Center for Mechanical Sciences, Udine, Italy, July 1-5, 1985 , 1987 .

[3]  S. Torquato,et al.  Connection between the conductivity and bulk modulus of isotropic composite materials , 1996, Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[4]  K. Hagberg,et al.  Osseointegrated Titanium Implants for Limb Prostheses Attachments: Infectious Complications , 2010, Clinical orthopaedics and related research.

[5]  A. H. Wilkins,et al.  Design of three dimensional isotropic microstructures for maximized stiffness and conductivity , 2007, 0712.3101.

[6]  Scott J. Hollister,et al.  Computational design of tissue engineering scaffolds , 2007 .

[7]  S. Hollister,et al.  Topology optimization of three dimensional tissue engineering scaffold architectures for prescribed bulk modulus and diffusivity , 2010, Structural and multidisciplinary optimization : journal of the International Society for Structural and Multidisciplinary Optimization.

[8]  G. J. Verkerke,et al.  A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses Fixations , 2010, Annals of Biomedical Engineering.

[9]  S A Meguid,et al.  Differences in osseointegration rate due to implant surface geometry can be explained by local tissue strains , 2001, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[10]  Gerald E Loeb,et al.  Taking control of prosthetic arms. , 2009, JAMA.

[11]  K. Hagberg,et al.  One hundred patients treated with osseointegrated transfemoral amputation prostheses--rehabilitation perspective. , 2009, Journal of rehabilitation research and development.

[12]  S. Goldstein,et al.  A paradigm for the development and evaluation of novel implant topologies for bone fixation: in vivo evaluation. , 2012, Journal of biomechanics.

[13]  T. McMahon,et al.  Trabecular bone exhibits fully linear elastic behavior and yields at low strains. , 1994, Journal of biomechanics.

[14]  Wei Xu,et al.  X-Ray Image Review of the Bone Remodeling Around an Osseointegrated Trans-femoral Implant and a Finite Element Simulation Case Study , 2008, Annals of Biomedical Engineering.

[15]  Chia-Ying Lin,et al.  Interbody Fusion Cage Design Using Integrated Global Layout and Local Microstructure Topology Optimization , 2004, Spine.

[16]  L. S. Matthews,et al.  Trabecular bone remodeling: an experimental model. , 1991, Journal of biomechanics.

[17]  S A Meguid,et al.  Mechanical regulation of localized and appositional bone formation around bone-interfacing implants. , 2001, Journal of biomedical materials research.

[18]  Chia-Ying Lin,et al.  Structural and mechanical evaluations of a topology optimized titanium interbody fusion cage fabricated by selective laser melting process. , 2007, Journal of biomedical materials research. Part A.

[19]  O. Sigmund Materials with prescribed constitutive parameters: An inverse homogenization problem , 1994 .

[20]  M. Bendsøe,et al.  Generating optimal topologies in structural design using a homogenization method , 1988 .

[21]  B. Rydevik,et al.  Osseointegration in skeletal reconstruction and rehabilitation: a review. , 2001, Journal of rehabilitation research and development.