Design and control of a three degree of freedom pneumatic physiotherapy robot

Stroke is a common condition resulting in 30,000 people per annum left with significant disability. In patients with severe arm paresis after stroke, functional recovery in the affected arm is poor. Inadequate intensity of treatment is cited as one factor accounting for the lack of arm recovery found in some studies. Given that physical therapy resource is limited, strategies to enhance the physiotherapists' efforts are needed. One approach is to use robotic techniques to augment movement therapy.A three degree-of-freedom pneumatic robot has been developed to apply physiotherapy to the upper limb. The robot has been designed with a workspace encompassing the reach-retrieve range of the average male. Control experiments have applied force and then position only controllers to the pneumatic robot. These controllers are combined to form a position-based impedance control strategy on all degrees of freedom of the robot. The impedance controller performance was found to be dependent upon the specified impedance parameters. Initial experiments attaching the device to human subjects have indicated great potential for the device.

[1]  Neville Hogan,et al.  Impedance Control: An Approach to Manipulation , 1984, 1984 American Control Conference.

[2]  Nariman Sepehri,et al.  Position-based impedance control of an industrial hydraulic manipulator , 1997 .

[3]  Chang-Ock Lee,et al.  A parallel Gauss - Seidel method using NR data flow ordering , 1999, Appl. Math. Comput..

[4]  Robert C. Richardson,et al.  Pneumatic impedance control for physiotherapy , 2000 .

[5]  James E. Bobrow,et al.  Modeling, identification, and control of a pneumatically actuated robot , 1997, Proceedings of International Conference on Robotics and Automation.

[6]  Andrew R. Plummer,et al.  Self-tuning control of a low-friction pneumatic actuator under the influence of gravity , 2001, IEEE Trans. Control. Syst. Technol..

[7]  N. Hogan,et al.  Robot-aided neurorehabilitation. , 1998, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[8]  J Bamford,et al.  A prospective study of acute cerebrovascular disease in the community: the Oxfordshire Community Stroke Project 1981-86. 1. Methodology, demography and incident cases of first-ever stroke. , 1988, Journal of neurology, neurosurgery, and psychiatry.

[9]  Yildirim Hurmuzlu,et al.  A High Performance Pneumatic Force Actuator System: Part I—Nonlinear Mathematical Model , 2000 .

[10]  J. Cozens Robotic assistance of an active upper limb exercise in neurologically impaired patients. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[11]  Lorenzo Sciavicco,et al.  The parallel approach to force/position control of robotic manipulators , 1993, IEEE Trans. Robotics Autom..

[12]  James E. Bobrow,et al.  An Analysis of a Pneumatic Servo System and Its Application to a Computer-Controlled Robot , 1988 .

[13]  John J. Craig,et al.  Hybrid position/force control of manipulators , 1981 .

[14]  C. Sabin,et al.  Observing the process of care: a stroke unit, elderly care unit and general medical ward compared. , 1999, Age and ageing.

[15]  I. Babuska,et al.  Finite Element Analysis , 2021 .

[16]  Lu-Ping Chao,et al.  The six-component force sensor for measuring the loading of the feet in locomotion , 1999 .

[17]  Neville Hogan,et al.  On the stability of manipulators performing contact tasks , 1988, IEEE J. Robotics Autom..

[18]  Sadao Kawamura,et al.  Development of an 8 DOF robotic orthosis for assisting human upper limb motion , 1998, Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146).

[19]  D. Wade,et al.  Enhanced physical therapy improves recovery of arm function after stroke. A randomised controlled trial. , 1992, Journal of neurology, neurosurgery, and psychiatry.

[20]  P. Gorce,et al.  Joint Impedance Pneumatic Control for Multilink Systems , 1999 .

[21]  M. E. Austin,et al.  Development of a physiotherapy robot , 1999 .

[22]  G. Kwakkel,et al.  Intensity of leg and arm training after primary middle-cerebral-artery stroke: a randomised trial , 1999, The Lancet.