MTF analysis of a prototype table-top inverse-geometry volumetric CT system

This work investigates the modulation transfer function (MTF) of a prototype table-top inverse-geometry volumetric CT (IGCT) system. The IGCT system has been proposed to acquire sufficient volumetric data in one circular rotation using a large-area scanned source and a narrower array of fast detectors. The source and detector arrays have the same axial, or slice, extent, thus providing sufficient volumetric coverage. A prototype system has been built using a NexRay Scanning-Beam Digital X-ray system (NexRay, Inc., Los Gatos, CA) with the C-arm gantry in the horizontal position and a stage placed between the source and detector to rotate the scanned object. The resulting system has a 16-cm in-plane field of view (FOV) and 5-cm axial FOV. Two phantoms were constructed for measuring the MTF. A 76 micron tungsten wire placed axially in a plastic frame was used to measure the in-plane MTF, and the same wire slanted at 45 degrees was used to test the isotropy of the MTF. The data were calibrated for flat-field intensity and geometric misalignment and reconstructed using a modified 3D PET algorithm. For both phantoms, slices perpendicular to the wires were reconstructed. Simulations which model the IGCT system were used to verify the MTF measurement, along with analytical predictions. The measured MTF curve was similar in shape to the predicted curve with a 10% point at 20 lp/cm compared to a predicted 18 lp/cm. Future work will also study the uniformity of the MTF across the FOV and further characterize the IGCT system.

[1]  David A Jaffray,et al.  Accurate technique for complete geometric calibration of cone-beam computed tomography systems. , 2005, Medical physics.

[2]  G T Gullberg,et al.  Estimation of geometrical parameters and collimator evaluation for cone beam tomography. , 1990, Medical physics.

[3]  T. M. Albert,et al.  Aerospace applications of X-ray system using reverse geometry , 1993 .

[4]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[5]  N. Pelc,et al.  An inverse-geometry volumetric CT system with a large-area scanned source: a feasibility study. , 2004, Medical physics.

[6]  Robert E. Melen,et al.  CdZnTe detector array for a scanning-beam digital x-ray system , 1999, Medical Imaging.

[7]  Willi A Kalender,et al.  Geometric misalignment and calibration in cone-beam tomography. , 2004, Medical physics.

[8]  Y. Trousset,et al.  Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction. , 1993, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[9]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[10]  Norbert J. Pelc,et al.  Noise simulations for an inverse-geometry volumetric CT system , 2004, SPIE Medical Imaging.

[11]  N J Pelc,et al.  Nonlinear partial volume artifacts in x-ray computed tomography. , 1980, Medical physics.

[12]  M Defrise,et al.  Three-dimensional image reconstruction from complete projections , 1989, Physics in medicine and biology.

[13]  Bruce D. Smith Cone-beam tomography: recent advances and a tutorial review , 1990 .

[14]  Taly Gilat Schmidt,et al.  A three-dimensional reconstruction algorithm for an inverse-geometry volumetric CT system. , 2005, Medical physics.

[15]  R Clackdoyle,et al.  Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography. , 2000, Physics in medicine and biology.

[16]  Norbert J. Pelc,et al.  Three-dimensional reconstruction algorithm for a reverse geometry volumetric CT system with a large-array scanned source , 2003, SPIE Medical Imaging.

[17]  Taly Gilat Schmidt,et al.  Geometry analysis of an inverse-geometry volumetric CT system with multiple detector arrays , 2004, SPIE Medical Imaging.

[18]  Edward G. Solomon,et al.  Scanning-beam digital x-ray (SBDX) system for cardiac angiography , 1999, Medical Imaging.