Intraoperative raster photogrammetry—the PAR Corneal Topography System

ABSTRACT The PAR Corneal Topography System (CTS) is a computer‐driven corneal imaging system that uses close‐range raster photogrammetry to measure and produce a topographic map of the corneal surface. The CTS determines distortion in a projected two‐dimensional grid. Unlike Placido‐disc‐based videokeratoscopes, the PAR CTS produces a true topographic map (elevation map) and requires neither a smooth reflective surface nor precise spatial alignment for accurate imaging. Because the system uses two noncoaxial optical paths, it can be integrated into other optical devices. A modified CTS was integrated into an experimental erbium: YAG photoablatioe laser. The CTS successfully imaged corneas before, after, and during laser photoablation. Its ability to image nonreflective surfaces and to be integrated into other optical systems may make it suitable for intraoperative refractive monitoring.

[1]  V. Lubkin,et al.  Corneal modeling. , 1988, Cornea.

[2]  J. W. Warnicki,et al.  Corneal topography using rasterstereography. , 1989, Refractive & corneal surgery.

[3]  D. Litoff,et al.  The PAR Technology Corneal Topography System. , 1992, Refractive & corneal surgery.

[4]  G O Waring,et al.  Accuracy and precision of keratometry, photokeratoscopy, and corneal modeling on calibrated steel balls. , 1989, Archives of ophthalmology.

[5]  G O Waring,et al.  Reproducibility of normal corneal power measurements with a keratometer, photokeratoscope, and video imaging system. , 1990, Archives of ophthalmology.

[6]  M. Tsilimbaris,et al.  Comparison of keratometric readings as obtained by Javal Ophthalmometer and Corneal Analysis System (EyeSys). , 1991, Refractive & corneal surgery.

[7]  D D Koch,et al.  Comparison of the accuracy and reproducibility of the keratometer and the EyeSys Corneal Analysis System Model I , 1992, Journal of cataract and refractive surgery.

[8]  S A Burns,et al.  Corneal topography using computer analyzed rasterstereographic images. , 1988, Applied optics.

[9]  D D Koch,et al.  The Corneal EyeSys System: accuracy analysis and reproducibility of first-generation prototype. , 1989, Refractive & corneal surgery.

[10]  M. Belin,et al.  Accuracy of the PAR corneal topography system with spatial misalignment. , 1993, The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc.

[11]  S. E. Hage A computerized corneal topographer for use in refractive surgery. , 1989 .