on definitions of joint coordinate system of various joints for the reporting of human joint motion — part I : ankle , hip , and spine

The Standardization and Terminology Committee (STC) of the International Society of Biomechanics (ISB) proposes a general reporting standard for joint kinematics based on the Joint Coordinate System (JCS), first proposed by Grood and Suntay for the knee joint in 1983 (J. Biomech. Eng. 105 (1983) 136). There is currently a lack of standard for reporting joint motion in the field of biomechanics for human movement, and the JCS as proposed by Grood and Suntay has the advantage of reporting joint motions in clinically relevant terms. In this communication, the STC proposes definitions of JCS for the ankle, hip, and spine. Definitions for other joints (such as shoulder, elbow, hand and wrist, temporomandibular joint (TMJ), and whole body) will be reported in later parts of the series. The STC is publishing these recommendations so as to encourage their use, to stimulate feedback and discussion, and to facilitate further revisions. For each joint, a standard for the local axis system in each articulating bone is generated. These axes then standardize the JCS. Adopting these standards will lead to better communication among researchers and clinicians. r 2002 Elsevier Science Ltd. All rights reserved.

[1]  Aurelio Cappozzo,et al.  Gait analysis methodology , 1984 .

[2]  W. Hayes,et al.  Cross-sectional geometry of Pecos Pueblo femora and tibiae--a biomechanical investigation: I. Method and general patterns of variation. , 1983, American journal of physical anthropology.

[3]  Y. Yoshioka,et al.  The anatomy and functional axes of the femur. , 1987, The Journal of bone and joint surgery. American volume.

[4]  A. Schultz,et al.  Force-deformation properties of human costo-sternal and costo-vertebral articulations. , 1974, Journal of biomechanics.

[5]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[6]  D R Pedersen,et al.  A comparison of the accuracy of several hip center location prediction methods. , 1990, Journal of biomechanics.

[7]  A Cappello,et al.  Effects of hip joint centre mislocation on gait analysis results. , 2000, Journal of biomechanics.

[8]  L Cristofolini,et al.  A critical analysis of stress shielding evaluation of hip prostheses. , 1997, Critical reviews in biomedical engineering.

[9]  S Toksvig-Larsen,et al.  Validation of a functional method for the estimation of hip joint centre location. , 1999, Journal of biomechanics.

[10]  P R Cavanagh,et al.  ISB recommendations for standardization in the reporting of kinematic data. , 1995, Journal of biomechanics.

[11]  M. Dijkers,et al.  Hip joint center location from palpable bony landmarks--a cadaver study. , 1995, Journal of biomechanics.

[12]  R. Brand,et al.  Three-dimensional flexibility and stiffness properties of the human thoracic spine. , 1976, Journal of biomechanics.

[13]  R. B. Davis,et al.  A gait analysis data collection and reduction technique , 1991 .