Construction and evaluation of a hydromechanical simulation facility for the assessment of mitral valve prostheses.

A hydromechanical simulator of the human left heart and systemic circulation system has been built for evaluating the dynamic actions of mitral valve prostheses. The facility includes a transparent and compliant model ventricle pumping into a simulation of the systemic circulation impedance. Transparent materials permit detailed high speed photography of valve action from the left ventricular aspect. This action has been analyzed by digitizing the valve open area and computing the variation of area with time. Additionally, pressures across and flows through the valves have been measured. Comparison has been made between the maximum observed valve open areas and the areas computed using the appropriate pressure and flow measurements substituted in clinically used equations.

[1]  N. Westerhof,et al.  An artificial arterial system for pumping hearts. , 1971, Journal of applied physiology.

[2]  R GORLIN,et al.  Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I. , 1951, American heart journal.

[3]  B. Bellhouse,et al.  Mechanism of Closure of the Aortic Valve , 1968, Nature.

[4]  A. Weissler,et al.  Systolic Time Intervals in Heart Failure in Man , 1968, Circulation.

[5]  R. Aaslid,et al.  "In situ" evaluation of the aortic pivoting disc valve prosthesis. , 1975, Scandinavian journal of thoracic and cardiovascular surgery.

[6]  Wright Jt,et al.  A method for measuring the mean pressure gradient across prosthetic heart valves under in vitro pulsatile flow conditions. , 1977 .

[7]  R. Gorlin,et al.  Modified orifice equation for the calculation of mitral valve area. , 1972, American heart journal.

[8]  P. Marchand,et al.  The Anatomy of the Mitral Valve and its Associated Structures , 1964, Thorax.

[9]  Charles S. Peskin,et al.  Large Amplitude Pulsatile Water Flow Across an Orifice , 1975 .

[10]  C. R. Gentle The Role of Simulation Studies in Cardiac Valve Prosthesis Design , 1978 .

[11]  Swanson Wm,et al.  Cardiovascular system simulation requirements. , 1977 .

[12]  Wright Jt A pulsatile flow study comparing the Hancock porcine xenograft aortic valve prostheses models 242 and 250. , 1977 .

[13]  J F Cornhill,et al.  An aortic--left ventricular pulse duplicator used in testing prosthetic aortic heart valves. , 1977, The Journal of thoracic and cardiovascular surgery.