Abstract Measurement of lift-off can be used to assess the thermal insulation thickness and it has the potential to reduce the lift-off effect in pulsed eddy current testing. In this paper, first, the relative variation of magnetic flux is proposed as a feature for the measurement of lift-off. And then, how to directly obtain the key parameters of the feature from the testing signals is provided. At last, the validity of the feature is verified by simulations and experiments, respectively. The results show that the feature is suitable when the lift-off is tens of millimeters and the plate is ferromagnetic.

[1]  M. Nabighian Quasi-static transient response of a conducting half-space; an approximate representation , 1979 .

[2]  Xinjun Wu,et al.  Assessment of wall thinning in insulated ferromagnetic pipes using the time-to-peak of differential pulsed eddy-current testing signals , 2012 .

[3]  C. Farias,et al.  Corrosion Inspection Using Pulsed Eddy Current , 2014 .

[4]  C. Mandache,et al.  Pulsed Eddy Current Measurement of Lift-Off , 2006 .

[5]  P. D. Agarwal Eddy-current losses in solid and laminated iron , 1959, Transactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics.

[6]  Yi Zhang,et al.  Pulsed eddy current transient technique with HTS SQUID magnetometer for non-destructive evaluation , 2002 .

[7]  Weiying Cheng,et al.  Simulation of Transient Eddy-Current Measurement for the Characterization of Depth and Conductivity of a Conductive Plate , 2008, IEEE Transactions on Magnetics.

[8]  Masahito Yoshizawa,et al.  Dual-frequency eddy-current NDE based on high-Tc rf SQUID , 2002 .

[9]  C. Mandache,et al.  Electromagnetic Enhancement of Pulsed Eddy Current Signals , 2007 .

[10]  Xinjun Wu,et al.  Ferromagnetic material pulsed eddy current testing signal modeling by equivalent multiple-coil-coupling approach , 2011 .

[11]  S. Berg Modelling and Inversion of Pulsed Eddy Current Data , 2003 .

[12]  Gui Yun Tian,et al.  DEFECT CLASSIFICATION USING A NEW FEATURE FOR PULSED EDDY CURRENT SENSORS , 2005 .

[13]  Alireza Bahadori,et al.  A simple correlation for estimation of economic thickness of thermal insulation for process piping and equipment , 2010 .

[14]  R. W. Baines,et al.  The research of inhomogeneity in eddy current sensors , 1998 .

[15]  Du Pingan,et al.  A new eddy current displacement measuring instrument independent of sample electromagnetic properties , 2012 .

[16]  Xinjun Wu,et al.  An improved ferromagnetic material pulsed eddy current testing signal processing method based on numerical cumulative integration , 2015 .

[17]  Yo Sakaki,et al.  Relationship among eddy current loss, frequency, maximum flux density and a new parameter concerning the number of domain walls in polycrystalline and amorphous soft magnetic materials , 1981 .

[18]  Weiying Cheng,et al.  Pulsed Eddy Current Testing of Carbon Steel Pipes’ Wall-thinning Through Insulation and Cladding , 2012 .