Trace analysis in EPMA

Trace element micro-analysis has evolved steadily since the early days of EPMA, yet remains an extraordinarily challenging subject. The enhanced capabilities of modern instrumentation, including the use of spectrometers with high X-ray collection efficiencies, high brightness electron sources, and improved stability all contribute to our ability to improve detection limits and analytical spatial resolution. Along with much improved software for data acquisition and analysis, recent progress in EPMA has made the trace realm more accessible than ever. High count precision can be obtained in order to easily bring analytical sensitivity into the single ppm range, but accuracy remains the greatest struggle. With the exception of the calibration, all sources of error encountered in major element analysis are magnified in trace analysis, and other sources become apparent where high spatial resolution is needed. Beam damage and charge effects are difficult problems in high sensitivity, high spatial resolution analysis, particularly in the analysis of insulators. Software can minimize some of the resulting effects on count rates during acquisition in order to improve accuracy, and analysts can empirically evaluate the conditions of analysis (count time, voltage, current, etc.) to try to minimize these effects. Trace analysis is fundamentally an exercise in background characterisation, and the acquisition and evaluation of background is a subject of developing methodology. Background curvature and interferences can result in considerable inaccuracy, but can be dealt with via detailed quantitative wavelength scanning or multi-point spectral acquisitions which allow proper regression of the background shape. In the absence of excellent quality trace element secondary standards of similar matrix to unknowns, blank testing and consistency standards can be used to test at least some aspects of the methods employed. Ultimately, the analyst must rely on accuracy evolving from application of the most rigorous protocols.

[1]  Thomas O. Ziebold,et al.  Precision and sensitivity in electron microprobe analysis , 1967 .

[2]  J. Goldstein,et al.  Distribution of germanium in the metallic phases of some iron meteorites , 1967 .

[3]  M. C. Cox,et al.  Electron probe microanalysis using oxygen x-rays: I. Mass absorption coefficients , 1974 .

[4]  S. J. B. Reed,et al.  Electron Microprobe Analysis , 1975 .

[5]  Michael J. Jercinovic,et al.  Dating metamorphic reactions and fluid flow: application to exhumation of high‐P granulites in a crustal‐scale shear zone, western Canadian Shield , 2006 .

[6]  Raynald Gauvin Introduction: Characterization of Nonconductive Materials , 2004, Microscopy and Microanalysis.

[7]  Claude Merlet,et al.  Distribution of trace transition elements in olivine and pyroxenes from ultramafic xenoliths; application of microprobe analysis , 1987 .

[8]  Dominique Drouin,et al.  CASINO V2.42: a fast and easy-to-use modeling tool for scanning electron microscopy and microanalysis users. , 2007, Scanning.

[9]  Godfried M. Roomans,et al.  X-Ray microanalysis , 1982 .

[10]  J. W. Martin The local chemical analysis of materials , 2003 .

[11]  G. Bastin,et al.  Quantitative Electron Probe Microanalysis of Nonconducting Specimens: Science or Art? , 2004, Microscopy and Microanalysis.

[12]  J. Cazaux,et al.  Electron Probe Microanalysis of Insulating Materials: Quantification Problems and Some Possible Solutions , 1996 .

[13]  Claude Merlet,et al.  Electron microprobe determination of minor and trace transition elements in silicate minerals: A method and its application to mineral zoning in the peridotite nodule PHN 1611 , 1990 .

[14]  Stephen J. B. Reed,et al.  Quantitative Trace Analysis by Wavelength-Dispersive EPMA , 2000, Microchimica Acta.

[15]  Martin J T Milton,et al.  Analytical techniques for trace element analysis: an overview , 2005 .

[16]  Michael J. Jercinovic,et al.  Format and philosophy for collecting, compiling, and reporting microprobe monazite ages , 2006 .

[17]  M. P. Smith,et al.  Silver Coating Inhibits Electron Microprobe Beam Damage of Carbonates: RESEARCH METHOD PAPER , 1986 .

[18]  John H. Fournelle,et al.  The Problem of Secondary Fluorescence in EPMA in the Application of the Ti-in-Zircon Geothermometer and the Utility of PENEPMA Monte Carlo Program , 2007, Microscopy and Microanalysis.

[19]  Christiane Wagner,et al.  Trace element analysis with the electron microprobe: New data and perspectives , 1999 .

[20]  Michael J. Jercinovic,et al.  Analytical perils (and progress) in electron microprobe trace element analysis applied to geochronology: Background acquisition, interferences, and beam irradiation effects , 2005 .

[21]  Michael J. Jercinovic,et al.  Th–U–total Pb geochronology of authigenic monazite in the Adelaide rift complex, South Australia, and implications for the age of the type Sturtian and Marinoan glacial deposits , 2010 .

[22]  G. Blaise,et al.  Charge dynamics of MgO single crystals subjected to KeV electron irradiation , 2004 .

[23]  N. Doganaksoy,et al.  Statistical Considerations in Microanalysis by Energy-Dispersive Spectrometry , 1998, Microscopy and Microanalysis.

[24]  Terry Alford,et al.  Fundamentals of Nanoscale Film Analysis , 2007 .

[25]  Roger Powell,et al.  Formation of eclogite, and reaction during exhumation to mid‐crustal levels, Snowbird tectonic zone, western Canadian Shield , 2007 .

[26]  Michael J. Jercinovic,et al.  In-situ trace element analysis of monazite and other fine-grained accessory minerals by EPMA , 2008 .

[27]  John J. Donovan,et al.  Improved electron probe microanalysis of trace elements in quartz , 2011 .

[28]  Michael J. Jercinovic,et al.  Geochronology: Understanding Geologic Processes by Integrating Composition and Chronology , 2007 .

[29]  David J. Vaughan,et al.  Modern approaches to ore and environmental mineralogy , 1998 .

[30]  Frank S. Spear,et al.  Contributions to precision and accuracy of monazite microprobe ages , 2005 .

[31]  Omar Jbara,et al.  Electron Probe Microanalysis of Insulating Oxides: Monte Carlo Simulations , 1997 .

[32]  G. Lawes,et al.  Scanning Electron Microscopy and X-Ray Microanalysis , 1987 .

[33]  Michael J. Jercinovic,et al.  High-resolution dating of granite petrogenesis and deformation in a lower crustal shear zone: Athabasca granulite terrane, Western Canadian Shield , 2008 .

[34]  R. Thresher,et al.  Electron probe microanalysis of fish otoliths — evaluation of techniques for studying age and stock discrimination , 1992 .