Detection of Power Transformer Winding Deformation Using Improved FRA Based on Binary Morphology and Extreme Point Variation

Frequency response analysis (FRA) has recently been developed as a widely accepted tool for power transformer winding mechanical deformation diagnosis, and has proven to be effective and powerful in many cases. However, there still exist problems regarding the application of FRA. FRA is a comparative method in which the measured FRA signature should be compared with its fingerprint. Small differences of FRA signatures in certain frequency bands might be produced by external disturbance, which hinders fault diagnosis. Additionally, the existing correlation coefficient indicator recommended by power industry standards cannot reflect key information of signatures, namely the extreme points. This paper proposes an improved FRA based on binary morphology and extreme point variation. Binary morphology is first introduced to extract the certain frequency bands of signatures with significant difference. A composite indicator of extreme point variation is adopted to realize the diagnosis of fault level. A ternary diagram is constructed by the area proportions of the binary image to identify winding faults, which has a potential to realize cluster analysis of fault types.

[1]  E. Arri,et al.  Diagnosis of the state of power transformer windings by on-line measurement of stray reactance , 1993 .

[2]  Sung-Chin Hahn,et al.  Experimental Verification and Finite Element Analysis of Short-Circuit Electromagnetic Force for Dry-Type Transformer , 2012, IEEE Transactions on Magnetics.

[3]  G. B. Gharehpetian,et al.  ANN and cross-correlation based features for discrimination between electrical and mechanical defects and their localization in transformer winding , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  Viktor Öwall,et al.  Binary Morphology With Spatially Variant Structuring Elements: Algorithm and Architecture , 2009, IEEE Transactions on Image Processing.

[5]  Andrea Cavagnino,et al.  New Trends in Electrical Machines Technology—Part II , 2014, IEEE Transactions on Industrial Electronics.

[6]  Nicola Femia,et al.  Transformer Design for Isolated Switching Converters Based on Geometric Form Factors of Magnetic Cores , 2013, IEEE Transactions on Industrial Electronics.

[7]  A. Abu-Siada,et al.  A Novel Online Technique to Detect Power Transformer Winding Faults , 2012, IEEE Transactions on Power Delivery.

[8]  K.G.N.B. Abeywickrama,et al.  Computation of Parameters of Power Transformer Windings for Use in Frequency Response Analysis , 2007, IEEE Transactions on Magnetics.

[9]  Antonios G. Kladas,et al.  Power Transformer Economic Evaluation in Decentralized Electricity Markets , 2012, IEEE Transactions on Industrial Electronics.

[10]  A. Abu-Siada,et al.  Understanding power transformer frequency response analysis signatures , 2013, IEEE Electrical Insulation Magazine.

[11]  Chenguo Yao,et al.  Transformer winding deformation diagnostic system using online high frequency signal injection by capacitive coupling , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  M. S. Naderi,et al.  Advanced transformer winding deformation diagnosis: moving from off-line to on-line , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[13]  Fenghua Wang,et al.  Fault Diagnosis of On-Load Tap-Changer in Converter Transformer Based on Time–Frequency Vibration Analysis , 2016, IEEE Transactions on Industrial Electronics.

[14]  Guillermo Aponte Mayor,et al.  Current Status and Future Trends in Frequency-Response Analysis With a Transformer in Service , 2013, IEEE Transactions on Power Delivery.

[15]  Mohammad Hamed Samimi,et al.  FRA interpretation using numerical indices: State-of-the-art , 2017 .

[16]  Liu Qisheng,et al.  Study on ultrasonic measurement device for transformer winding deformation , 2002, Proceedings. International Conference on Power System Technology.

[17]  Jimmy Cesar Gonzales Arispe,et al.  Detection of Failures Within Transformers by FRA Using Multiresolution Decomposition , 2014, IEEE Transactions on Power Delivery.

[18]  K. Feser,et al.  Transfer Function Method to Diagnose Axial Displacement and Radial Deformation of Transformer Winding , 2002, IEEE Power Engineering Review.

[19]  Chenguo Yao,et al.  Impact of capacitive coupling circuit on online impulse frequency response of a power transformer , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[20]  Juan Carlos Burgos,et al.  Winding deformations detection in power transformers by tank vibrations monitoring , 2005 .

[21]  A.J. Vandermaar,et al.  Improved detection of power transformer winding movement by extending the FRA high frequency range , 2005, IEEE Transactions on Power Delivery.

[22]  V. A. Lavrinovich,et al.  Development of pulsed method for diagnostics of transformer windings based on short probe impulse , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[23]  A. Setayeshmehr,et al.  Diagnosing Shorted Turns on the Windings of Power Transformers Based Upon Online FRA Using Capacitive and Inductive Couplings , 2011, IEEE Transactions on Power Delivery.

[24]  Guillermo Aponte Mayor,et al.  Detection of Transformer Faults Using Frequency-Response Traces in the Low-Frequency Bandwidth , 2014, IEEE Transactions on Industrial Electronics.

[25]  A. Setayeshmehr,et al.  Sweep frequency response analysis for diagnosis of low level short circuit faults on the windings of power transformers: An experimental study , 2012 .

[26]  D.M. Sofian,et al.  Interpretation of Transformer FRA Responses— Part I: Influence of Winding Structure , 2009, IEEE Transactions on Power Delivery.

[27]  W H Tang,et al.  Detection of minor winding deformation fault in high frequency range for power transformer , 2010, IEEE PES General Meeting.

[28]  Yasser Abdel-Rady I. Mohamed,et al.  Experimental Studies on Monitoring and Metering of Radial Deformations on Transformer HV Winding Using Image Processing and UWB Transceivers , 2015, IEEE Transactions on Industrial Informatics.

[29]  Xinhua Zhuang,et al.  Image Analysis Using Mathematical Morphology , 1987, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[30]  Chenguo Yao,et al.  Determination of nanosecond pulse parameters on transfer function measurement for power transformer winding deformation , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[31]  Mehdi Bagheri,et al.  Frequency response analysis and short-circuit impedance measurement in detection of winding deformation within power transformers , 2013, IEEE Electrical Insulation Magazine.

[32]  W. Ziomek,et al.  Investigation of transformer model winding deformation using sweep frequency response analysis , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[33]  Gevork B. Gharehpetian,et al.  Determination of Transformer Winding Radial Deformation Using UWB System and Hyperboloid Method , 2015, IEEE Sensors Journal.

[34]  W.H. Tang,et al.  Transformer Core Parameter Identification Using Frequency Response Analysis , 2010, IEEE Transactions on Magnetics.

[35]  A. Abu-Siada,et al.  A new approach to identify power transformer criticality and asset management decision based on dissolved gas-in-oil analysis , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[36]  Stefan Tenbohlen,et al.  Mathematical Comparison Methods to Assess Transfer Functions of Transformers to Detect Different Types of Mechanical Faults , 2010, IEEE Transactions on Power Delivery.

[37]  Jack-Gérard Postaire,et al.  Cluster Analysis by Binary Morphology , 1993, IEEE Trans. Pattern Anal. Mach. Intell..