First time description of early lead failure of the Linox Smart lead compared to other contemporary high-voltage leads
暂无分享,去创建一个
R. Kobza | B. Berte | S. Toggweiler | M. Brinkert | Tobias Nyffenegger | Vanessa Weberndörfer | Ian Russi
[1] H. Morita,et al. Comparison of longevity and clinical outcomes of implantable cardioverter-defibrillator leads among manufacturers. , 2017, Heart rhythm.
[2] S. Hoeks,et al. Comparative study of the failure rates among 3 implantable defibrillator leads. , 2016, Heart rhythm.
[3] S. Kalbfleisch,et al. The Impact of Inappropriate Implantable Cardiac Defibrillator Shocks on Cardiovascular Morbidity and Mortality , 2016, Pacing and clinical electrophysiology : PACE.
[4] M. Orlov,et al. Long‐Term Evaluation of Biotronik Linox and Linoxsmart Implantable Cardioverter Defibrillator Leads , 2016, Journal of cardiovascular electrophysiology.
[5] H. Servatius,et al. Failure rate and conductor externalization in the Biotronik Linox/Sorin Vigila implantable cardioverter-defibrillator lead. , 2016, Heart rhythm.
[6] C. Sticherling,et al. Repetitive inappropriate implantable cardioverter-defibrillator shocks due to insulation failure with externalized conductor cables of a Biotronik Linox SD ICD lead. , 2016, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.
[7] Laura A. Hatfield,et al. Transvenous Implantable Cardioverter‐Defibrillator (ICD) Lead Performance: A Meta‐Analysis of Observational Studies , 2015, Journal of the American Heart Association.
[8] G. Marcus,et al. Utilization trends and clinical outcomes in patients implanted with a single- vs a dual-coil implantable cardioverter-defibrillator lead: Insights from the ALTITUDE Study. , 2015, Heart rhythm.
[9] C. M. Wilson,et al. Insulation Failure of the Linox Defibrillator Lead: A Case Report and Retrospective Review of a Single Center Experience , 2015, Journal of cardiovascular electrophysiology.
[10] J. Bashir,et al. Early Failure of the Biotronik Linox Implantable Cardioverter Defibrillator Lead , 2015, Journal of cardiovascular electrophysiology.
[11] S. Saba,et al. Failure rates of single- versus dual-coil nonrecalled sprint quattro defibrillator leads. , 2015, The American journal of cardiology.
[12] S. Pedersen,et al. The patient perspective on the Riata defibrillator lead advisory: a Danish nationwide study. , 2014, Heart rhythm.
[13] B. Wilkoff,et al. Conductor externalization of the Biotronik Kentrox internal cardioverter-defibrillator lead: the tip of another iceberg? , 2014, Heart rhythm.
[14] Joseph A. Manfredi,et al. Insulation Failure with Externalized Conductor of a Linox SD Lead: A Case Report , 2014, Journal of cardiovascular electrophysiology.
[15] H. Tanner,et al. Prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST implantable cardioverter-defibrillator leads. , 2013, International journal of cardiology.
[16] L. Poggio,et al. Failure of implantable cardioverter-defibrillator leads: a matter of lead size? , 2013, Heart rhythm.
[17] A. Compare,et al. Post-traumatic stress disorder, emotional processing and inappropriate implantable cardioverter-defibrillator shocks: clinical consideration by a single case report. , 2012, Monaldi archives for chest disease = Archivio Monaldi per le malattie del torace.
[18] M. Hochadel,et al. Comparison Between Atrial Fibrillation‐Triggered Implantable Cardioverter‐Defibrillator (ICD) Shocks and Inappropriate Shocks Caused by Lead Failure: Different Impact on Prognosis in Clinical Practice , 2012, Journal of cardiovascular electrophysiology.
[19] Abrar H. Shah,et al. Time-dependent risk of Fidelis lead failure. , 2010, The American journal of cardiology.