PEM fuel cell fault detection and identification using differential method: simulation and experimental validation

PEM fuel cell performance and lifetime strongly depend on the polymer membrane and MEA hydration. As the internal moisture is very sensitive to the operating conditions (temperature, stoichiometry, load current, water management…), keeping the optimal working point is complex and requires real-time monitoring. This article focuses on PEM fuel cell stack health diagnosis and more precisely on stack fault detection monitoring. This paper intends to define new, simple and effective methods to get relevant information on usual faults or malfunctions occurring in the fuel cell stack. For this purpose, the authors present a fault detection method using simple and non-intrusive on-line technique based on the space signature of the cell voltages. The authors have the objective to minimize the number of embedded sensors and instrumentation in order to get a precise, reliable and economic solution in a mass market application. A very low number of sensors are indeed needed for this monitoring and the associated algorithm can be implemented on-line. This technique is validated on a 20-cell PEMFC stack. It demonstrates that the developed method is particularly efficient in flooding case. As a matter of fact, it uses directly the stack as a sensor which enables to get a quick feedback on its state of health.

[1]  P. Lin,et al.  A high efficient assembly technique for large PEMFC stacks: Part I. Theory , 2009 .

[2]  U. Wagner,et al.  Experimental analysis of water management in a self-humidifying polymer electrolyte fuel cell stack , 2004 .

[3]  V. Vishnyakov Proton exchange membrane fuel cells , 2006 .

[4]  Jiujun Zhang,et al.  A review of water flooding issues in the proton exchange membrane fuel cell , 2008 .

[5]  Fortunato Migliardini,et al.  Performance investigation of 2.4 kW PEM fuel cell stack in vehicles , 2007 .

[6]  Thomas A. Trabold,et al.  Voltage instability in a simulated fuel cell stack correlated to cathode water accumulation , 2007 .

[7]  Tomoki Akita,et al.  Analysis of degradation in PEMFC caused by cell reversal during air starvation , 2008 .

[8]  Belkacem Ould-Bouamama,et al.  Model based PEM fuel cell state-of-health monitoring via ac impedance measurements , 2006 .

[9]  Fjo De Ridder,et al.  Evaluation of an on-site cell voltage monitor for fuel cell systems , 2008 .

[10]  B. Wetton,et al.  Flow distribution in proton exchange membrane fuel cell stacks , 2006 .

[11]  Frano Barbir,et al.  PEM Fuel Cells , 2006 .

[12]  Jerald A. Caton,et al.  Development of a PEM stack and performance analysis including the effects of water content in the membrane and cooling method , 2008 .

[13]  Giuseppe Marco Tina,et al.  PEM fuel cell testing by electrochemical impedance spectroscopy , 2009 .

[14]  A. Taniguchi,et al.  Analysis of electrocatalyst degradation in PEMFC caused by cell reversal during fuel starvation , 2004 .

[15]  Daniel Hissel,et al.  Analysis of a PEMFC durability test under low humidity conditions and stack behaviour modelling using experimental design techniques , 2008 .

[16]  C. Bordons,et al.  Development and experimental validation of a PEM fuel cell dynamic model , 2007 .

[17]  M. Péra,et al.  Oxygen starvation analysis during air feeding faults in PEMFC , 2010 .

[18]  Chang-Soo Kim,et al.  The influence of stack clamping pressure on the performance of PEM fuel cell stack , 2010 .

[19]  Kodjo Agbossou,et al.  Local Voltage Degradations (Drying and Flooding) Analysis Through 3D Stack Thermal Modeling , 2010 .

[20]  P. Rodatz,et al.  Operational aspects of a large PEFC stack under practical conditions , 2004 .

[21]  M.H. Nehrir,et al.  Dynamic models and model validation for PEM fuel cells using electrical circuits , 2005, IEEE Transactions on Energy Conversion.

[22]  Frano Barbir,et al.  CHAPTER 7 – Fuel Cell Modeling , 2005 .

[23]  James Larminie,et al.  Fuel Cell Systems Explained , 2000 .

[24]  Daniel Hissel,et al.  Characterisation and modelling of a 5 kW PEMFC for transportation applications , 2006 .

[25]  Marie-Cécile Péra,et al.  Fuel cells multi-stack power architectures and experimental validation of 1 kW parallel twin stack PEFC generator based on high frequency magnetic coupling dedicated to on board power unit , 2008 .

[26]  Jiujun Zhang,et al.  Diagnostic tools in PEM fuel cell research: Part I Electrochemical techniques , 2008 .

[27]  James Larminie,et al.  Fuel Cell Systems Explained: Larminie/Fuel Cell Systems Explained , 2003 .

[28]  Jer‐Huan Jang,et al.  Effects of operating conditions on the performances of individual cell and stack of PEM fuel cell , 2008 .

[29]  Nobuyuki Kitamura,et al.  Recent Advances in TOYOTA FCHV-adv Fuel Cell System , 2010 .

[30]  Sébastien Wasterlain APPROCHES EXPERIMENTALES ET ANALYSE PROBABILISTE POUR LE DIAGNOSTIC DE PILES A COMBUSTIBLE DE TYPE PEM. , 2010 .

[31]  Ali Zolghadri,et al.  Caractérisation LPV des systèmes non linéaires plats. Application à un Démonstrateur de Rentrée Atmosphérique. , 2008 .

[32]  Phatiphat Thounthong,et al.  Online humidification diagnosis of a PEMFC using a static DC-DC converter , 2009 .

[33]  Thomas A. Trabold,et al.  In situ investigation of water transport in an operating PEM fuel cell using neutron radiography: Part 2 – Transient water accumulation in an interdigitated cathode flow field , 2006 .

[34]  Martin S. Miller,et al.  A review of polymer electrolyte membrane fuel cell stack testing , 2011 .

[35]  Nigel M. Sammes,et al.  Model-based condition monitoring of PEM fuel cell using Hotelling T2 control limit , 2006 .

[36]  Steffen Møller-Holst,et al.  Measuring individual cell voltages in fuel cell stacks , 2001 .

[37]  Xianguo Li,et al.  Analysis of liquid water transport in cathode catalyst layer of PEM fuel cells , 2010 .

[38]  Donald R. Cahela,et al.  Uniformity analysis at MEA and stack Levels for a Nexa PEM fuel cell system , 2004 .

[39]  D. Wilkinson,et al.  Aging mechanisms and lifetime of PEFC and DMFC , 2004 .

[40]  Sophie Didierjean,et al.  Design of an 80 kWe PEM fuel cell system: Scale up effect investigation , 2008 .

[41]  Stéphan Astier,et al.  A Large-Signal and Dynamic Circuit Model of a $\hbox{H}_{2}/\hbox{O}_{2}$ PEM Fuel Cell: Description, Parameter Identification, and Exploitation , 2010, IEEE Transactions on Industrial Electronics.

[42]  Daniel Hissel,et al.  Diagnostic d'une pile à combustible PEMFC: une approche statistique , 2008 .

[43]  Daniel Hissel,et al.  A review on PEM voltage degradation associated with water management: Impacts, influent factors and characterization , 2008 .

[44]  Daniel Hissel,et al.  Study of temperature, air dew point temperature and reactant flow effects on proton exchange membrane fuel cell performances using electrochemical spectroscopy and voltammetry techniques , 2010 .

[45]  A. Stefanopoulou,et al.  ANALYSIS, MODELING, AND VALIDATION FOR THE THERMAL DYNAMICS OF A POLYMER ELECTROLYTE MEMBRANE FUEL CELL SYSTEM , 2005 .