Direct torque control for interior permanent magnet synchronous motors with respect to optimal efficiency

Due to their high torque and power per volume ratio, interior permanent magnet synchronous motors (IPMSM) are widespread electrical machines for traction drive applications, e.g. in the drive train of hybrid electric vehicles (HEV). IPMSM exhibit a significant degree of saliency along the rotor circumference. Thus, in order to exploit the full potential of an IPMSM drive, it is mandatory to utilize the reluctance torque. As a result, using a rotor flux oriented torque control, the clear separation between flux and torque generating currents is no longer possible, i.e. that the determination of the reference currents for the subordinated current control is rather difficult. Furthermore, drive applications demand for a wide constant power range with flux weakening ratios of up to 1:5 or even higher. However, flux weakening operation demands for additional measures to ensure that the current controllers dispose of a minimum amount of voltage reserve, which is necessary to govern transients and to compensate for disturbances. In this contribution a Direct Torque Control (DTC) structure is proposed to cope with the afore mentioned problems. In a DTC structure, torque and flux are controlled directly. Hence, the approach is very well suited for operation at saturated voltage. Furthermore, with torque and flux as control variables, it is not necessary to determine any reference currents. However, the proposed structure utilizes two Look Up Tables (LUT) for the determination of efficiency-optimal set values for flux and torque. The LUT are generated based on measurement results. So, they do already account for saturation effects. The proposed DTC structure has been implemented and verified on a test bed.

[1]  M. F. Rahman,et al.  A direct torque controlled interior permanent magnet synchronous motor drive incorporating field weakening , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[2]  G. Friedrich,et al.  Comparisons of direct and adaptative optimal controls for interior permanent magnet synchronous integrated starter generator , 2003, IEEE International Electric Machines and Drives Conference, 2003. IEMDC'03..

[3]  Christos Mademlis,et al.  Loss minimization in vector-controlled interior permanent-magnet synchronous motor drives , 2002, IEEE Trans. Ind. Electron..

[4]  S. Morimoto,et al.  Expansion of operating limits for permanent magnet motor by current vector control considering inverter capacity , 1990 .

[5]  Toshihiko Noguchi,et al.  A New Quick-Response and High-Efficiency Control Strategy of an Induction Motor , 1986, IEEE Transactions on Industry Applications.

[6]  Ebrahim Arefi Moghadam,et al.  Loss Minimization Control of Permanent Magnet Synchronous Motor Drives , 2008 .

[7]  Lixin Tang,et al.  Problems associated with the direct torque control of an interior permanent-magnet synchronous motor drive and their remedies , 2004, IEEE Transactions on Industrial Electronics.

[8]  S.-M. Sue,et al.  A linear maximum torque per ampere control for IPMSM drives over full-speed range , 2005, IEEE Transactions on Energy Conversion.

[9]  C. Mademlis,et al.  On Considering Magnetic Saturation with Maximum Torque to Current Control in Interior Permanent Magnet Synchronous Motor Drives , 2001, IEEE Power Engineering Review.

[10]  Joachim Bocker,et al.  Optimum Control for Interior Permanent Magnet Synchronous Motors (IPMSM) in Constant Torque and Flux Weakening Range , 2006, 2006 12th International Power Electronics and Motion Control Conference.

[11]  Shigeo Morimoto,et al.  Loss minimization control of permanent magnet synchronous motor drives , 1994, IEEE Trans. Ind. Electron..