The Challenging Patient

The aforementioned scenarios represent just some of the challenges that can be observed around the CT scanner in everyday practice. Despite being coined a “challenge,” the challenging patient represents an objective issue in clinical management. However, with the continuous technological and pharmacological advances in addition to an effective training of CT personnel, we are nowadays able to effectively face and overcome many of these issues, all in an effort to guarantee safe and adequate examinations for all patients.

[1]  H. Bruder,et al.  Pushing the envelope: new computed tomography techniques for cardiothoracic imaging. , 2010, Journal of thoracic imaging.

[2]  Matthijs Oudkerk,et al.  Coronary angiography with multi-slice computed tomography , 2001, The Lancet.

[3]  Filippo Cademartiri,et al.  Incremental value and safety of oral ivabradine for heart rate reduction in computed tomography coronary angiography. , 2012, International Journal of Cardiology.

[4]  Long Jiang Zhang,et al.  Contrast-induced nephropathy in CT: incidence, risk factors and strategies for prevention , 2016, European Radiology.

[5]  S. Abbara,et al.  Patient preparation and scanning techniques. , 2010, Radiologic clinics of North America.

[6]  Sachil Shah,et al.  Acute Myocardial Infarction During Regadenoson Myocardial Perfusion Imaging , 2013, Pharmacotherapy.

[7]  Hirokazu Okada,et al.  Guidelines on the use of iodinated contrast media in patients with kidney disease 2012: digest version , 2013, Clinical and Experimental Nephrology.

[8]  U. Schoepf,et al.  Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction , 2013, European Radiology.

[9]  J. Gore,et al.  Prehospital Delay in Patients With Acute Coronary Syndromes (from the Global Registry of Acute Coronary Events [GRACE]). , 2009, The American journal of cardiology.

[10]  P. Grayburn,et al.  Non-invasive coronary angiography using multislice computed tomography , 2005, Heart.

[11]  T. Leiner,et al.  Sublingual Nitroglycerin Administration in Coronary Computed Tomography Angiography: a Systematic Review , 2015, European Radiology.

[12]  U. Schoepf,et al.  Prospectively ECG-Triggered Sequential Dual-Source Coronary CT Angiography in Patients with Atrial Fibrillation: Influence of Heart Rate on Image Quality and Evaluation of Diagnostic Accuracy , 2015, PloS one.

[13]  Zhonghua Sun,et al.  Beta-blocker administration protocol for prospectively ECG-triggered coronary CT angiography. , 2013, World journal of cardiology.

[14]  K. Egstrup,et al.  Pre-treatment with a sinus node blockade, ivabradine, before coronary CT angiography: a retrospective audit. , 2013, Clinical radiology.

[15]  U. Schoepf,et al.  Beyond stenosis detection: computed tomography approaches for determining the functional relevance of coronary artery disease. , 2015, Radiologic clinics of North America.

[16]  E. Depuey,et al.  Regadenoson and seizures: A real clinical concern , 2014, Journal of Nuclear Cardiology.

[17]  P. Aspelin,et al.  Contrast induced nephropathy: updated ESUR Contrast Media Safety Committee guidelines , 2011, European Radiology.

[18]  Damiano Caruso,et al.  Dynamic CT myocardial perfusion imaging. , 2016, European journal of radiology.

[19]  U. Schoepf,et al.  Evolving CT applications in ischemic heart disease. , 2008, Seminars in thoracic and cardiovascular surgery.

[20]  U Joseph Schoepf,et al.  CT of coronary artery disease. , 2004, Journal of thoracic imaging.

[21]  Ashley M. Lee,et al.  Coronary computed tomography angiography at 140 kV versus 120 kV: assessment of image quality and radiation exposure in overweight and moderately obese patients , 2014, Acta radiologica.

[22]  J. Leipsic,et al.  State of the Art: Iterative CT Reconstruction Techniques. , 2015, Radiology.

[23]  H. Sochor,et al.  Ivabradine versus metoprolol for heart rate reduction before coronary computed tomography angiography. , 2012, The American journal of cardiology.

[24]  U. Luft,et al.  Regadenoson induced acute ST-segment elevation myocardial infarction and multivessel coronary thrombosis , 2013, Journal of Nuclear Cardiology.

[25]  U. Schoepf,et al.  Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience , 2014, European Radiology.

[26]  U. Schoepf,et al.  Coronary computed tomographic angiography in clinical practice: state of the art. , 2015, Radiologic clinics of North America.

[27]  Bernhard Schmidt,et al.  Computed tomographic assessment of coronary artery disease: state-of-the-art imaging techniques. , 2015, Radiologic clinics of North America.

[28]  Akos Varga-Szemes,et al.  CT myocardial perfusion imaging. , 2015, AJR. American journal of roentgenology.

[29]  U. Schoepf,et al.  Diagnostic accuracy of coronary CT angiography using 3rd-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population , 2017, European Radiology.

[30]  E. Fishman,et al.  Beta-blockers for cardiac CT: a primer for the radiologist. , 2006, AJR. American journal of roentgenology.

[31]  Michael Fiechter,et al.  Impact of a new motion-correction algorithm on image quality of low-dose coronary CT angiography in patients with insufficient heart rate control. , 2014, Academic radiology.

[32]  Udo Hoffmann,et al.  ACR Appropriateness Criteria Acute Nonspecific Chest Pain-Low Probability of Coronary Artery Disease. , 2012, Journal of the American College of Radiology : JACR.

[33]  K. Jin,et al.  Myocardial perfusion imaging with dual energy CT. , 2016, European journal of radiology.

[34]  Jawdat Abdulla,et al.  Diagnostic accuracy and radiation dose of CT coronary angiography in atrial fibrillation: systematic review and meta-analysis. , 2013, Radiology.

[35]  J. Stehli,et al.  Image quality of low-dose CCTA in obese patients: impact of high-definition computed tomography and adaptive statistical iterative reconstruction , 2013, The International Journal of Cardiovascular Imaging.

[36]  Christine M. Carr,et al.  Computed Tomography-Derived Parameters of Myocardial Morphology and Function in Black and White Patients With Acute Chest Pain. , 2016, The American journal of cardiology.

[37]  N. Garg,et al.  Safety and efficacy of oral ivabradine as a heart rate-reducing agent in patients undergoing CT coronary angiography. , 2012, The British journal of radiology.

[38]  Simon Wildermuth,et al.  Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience , 2014, European Radiology.

[39]  U. Schoepf,et al.  Future of cardiac computed tomography. , 2015, World journal of radiology.

[40]  J. T. Barron,et al.  Development of asystole requiring cardiac resuscitation after the administration of regadenoson in a patient with pulmonary fibrosis receiving n-acetylcysteine , 2011, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[41]  N. Paul,et al.  Failed heart rate control with oral metoprolol prior to coronary CT angiography: effect of additional intravenous metoprolol on heart rate, image quality and radiation dose , 2012, The International Journal of Cardiovascular Imaging.

[42]  U. Schoepf,et al.  Comparison of dual-energy computed tomography of the heart with single photon emission computed tomography for assessment of coronary artery stenosis and of the myocardial blood supply. , 2009, The American journal of cardiology.

[43]  Julia F. Barrett,et al.  Artifacts in CT: recognition and avoidance. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.

[44]  H. Alkadhi,et al.  Meta-analysis: Diagnostic Performance of Low-Radiation-Dose Coronary Computed Tomography Angiography , 2011, Annals of Internal Medicine.

[45]  C Georg,et al.  Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. , 2001, Radiology.

[46]  U. Schoepf,et al.  High-Pitch Coronary CT Angiography at 70 kVp With Low Contrast Medium Volume , 2014, Medicine.

[47]  K. Eagle,et al.  Delay to reperfusion in patients with acute myocardial infarction presenting to acute care hospitals: an international perspective. , 2010, European heart journal.

[48]  M. Cerqueira,et al.  Effects of age, gender, obesity, and diabetes on the efficacy and safety of the selective A2A agonist regadenoson versus adenosine in myocardial perfusion imaging integrated ADVANCE-MPI trial results. , 2008, JACC. Cardiovascular imaging.

[49]  T. Iwaki,et al.  Contrast medium volume to estimated glomerular filtration rate ratio as a predictor of contrast-induced nephropathy developing after elective percutaneous coronary intervention. , 2009, Journal of cardiology.

[50]  J. Leipsic,et al.  Reduced iodine load at CT pulmonary angiography with dual-energy monochromatic imaging: comparison with standard CT pulmonary angiography--a prospective randomized trial. , 2012, Radiology.

[51]  W. Jaber,et al.  Safety and tolerability of regadenoson in 514 SPECT MPI patients with and without coronary artery disease and submaximal exercise heart rate response , 2013, European Journal of Nuclear Medicine and Molecular Imaging.

[52]  M. Ertürk,et al.  Single dose ivabradine versus intravenous metoprolol for heart rate reduction before coronary computed tomography angiography (CCTA) in patients receiving long-term calcium channel-blocker therapy , 2014, Acta radiologica.

[53]  W. B. Meijboom,et al.  “In-house” pharmacological management for computed tomography coronary angiography: heart rate reduction, timing and safety of different drugs used during patient preparation , 2009, European Radiology.

[54]  M. Oudkerk,et al.  The dream of a one-stop-shop: Meta-analysis on myocardial perfusion CT. , 2015, European journal of radiology.

[55]  S. Shim,et al.  Improvement of image quality with beta-blocker premedication on ECG-gated 16-MDCT coronary angiography. , 2005, AJR. American journal of roentgenology.

[56]  U. Schoepf,et al.  Coronary CT angiography in obese patients using 3rd generation dual-source CT: effect of body mass index on image quality , 2016, European Radiology.

[57]  M. Kantarci,et al.  Efficacy of ivabradin to reduce heart rate prior to coronary CT angiography: comparison with beta-blocker. , 2012, Diagnostic and interventional radiology.