Error analysis and performance of different retention models in the transference of data from/to isocratic/gradient elution.

The transferability of retention data among isocratic and gradient RPLC elution modes is studied. For this purpose, 16 beta-blockers were chromatographed under both isocratic and gradient elution with acetonitrile-water mobile phases. Taking into account the elution mode where the experimental data come from, and the mode where the retention should be predicted, the following combinations are possible: isocratic predictions from (i) isocratic or (ii) gradient experimental designs; and gradient predictions from (iii) isocratic or (iv) gradient data. Each of these possibilities was checked using three retention models that relate the logarithm of the retention factor: (a) linearly and (b) quadratically with the volume fraction of organic solvent, and (c) linearly with a normalised mobile phase polarity parameter. The study was carried out under two different perspectives: a straightforward examination of the prediction errors and the analysis of the uncertainties derived from the variance-covariance matrix of the fitted models. The best combinations of prediction mode and model were: (i)-(b), (ii)-(c), (iii)-(b), and (iv)-(a) or (c).

[1]  H. Billiet,et al.  Gradien elution methods for predicting isocratic conditions , 1991 .

[2]  L. Snyder,et al.  Prediction of precise isocratic retention data from two or more gradient elution runs. Analysis of some associated errors , 1986 .

[3]  J. Dolan,et al.  DryLab computer simulation for high-performance liquid chromatographic method development. II. Gradient elution. , 1989, Journal of chromatography.

[4]  E. Lesellier,et al.  Computerized optimization of RP-HPLC separation with nonaqueous or partially aqueous mobile phases , 1997 .

[5]  William H. Press,et al.  Numerical Recipes: FORTRAN , 1988 .

[6]  J. R. Torres-Lapasió,et al.  Prediction of the retention in reversed-phase liquid chromatography using solute-mobile phase-stationary phase polarity parameters. , 2002, Journal of chromatography. A.

[7]  J. R. Torres-Lapasió,et al.  Interpretive optimisation strategy applied to the isocratic separation of phenols by reversed-phase liquid chromatography with acetonitrile-water and methanol-water mobile phases. , 2000, Journal of chromatography. A.

[8]  P. Jandera Predictive calculation methods for optimization of gradient elution using binary and ternary solvent gradients , 1989 .

[9]  L. Snyder,et al.  Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time III. Improving the accuracy of computer simulation. , 1999, Journal of chromatography. A.

[10]  C. Baiocchi,et al.  Prediction of HPLC retention times in gradient elution from isocratic data application to a set of non-homologous compounds and different stationary phases , 1989 .

[11]  E. Bosch,et al.  Linear solvation energy relationships in reversed-phase liquid chromatography. Prediction of retention from a single solvent and a single solute parameter , 1993 .

[12]  P. Nikitas,et al.  Effect of the organic modifier concentration on the retention in reversed-phase liquid chromatography I. General semi-thermodynamic treatment for adsorption and partition mechanisms. , 2002, Journal of chromatography. A.

[13]  L. Snyder,et al.  Separation of mixtures of o-phthalaldehyde-derivatized amino acids by reversed-phase gradient elution : Accuracy of computer simulation for predicting retention and band width , 1989 .

[14]  Juan José Baeza-Baeza,et al.  Global treatment of chromatographic data with MICHROM , 1997 .

[15]  N. Lundell Implementation and use of gradient predictions for optimization of reversed-phase liquid chromatography of peptides. Practical considerations. , 1993, Journal of chromatography.

[16]  C. Horváth,et al.  Retention in reversed-phase chromatography: partition or adsorption? , 1998, Journal of chromatography. A.

[17]  M. Khaledi,et al.  Gradient elution in micellar liquid chromatography. II. Organic modifier gradients. , 1994, Journal of chromatography. A.

[18]  Marta Lores,et al.  PREOPT-W: A Simulation Program for Off-line Optimization of Binary Gradient Separations in HPLC-I. Fundamentals and Overview , 1996, Comput. Chem..

[19]  T. Yoshida,et al.  Prediction of peptide retention times in normal-phase liquid chromatography with only a single gradient run. , 1999, Journal of chromatography. A.

[20]  H. Billiet,et al.  Gradient selection in reversed-phase liquid chromatography , 1978 .