Creep and true wear of polyethylene are difficult to evaluate on radiographs of knee arthroplasties and for this reason the true rate of polyethylene wear in vivo after unicompartmental arthroplasty is not well known. This study evaluated the creep and true wear in fifty-five medial retrieved unicompartmental implants that had a flat articular surface at the time of implantation. All the full polyethylene tibial components had the same design and were retrieved from eleven to 224 months (mean 152 months) after their implantation. The postoperative varus deformity had been measured on weight-bearing radiographs of the whole limb (hip-knee-ankle angle). The retrieved implants were placed in a coordinate measuring machine and the coordinates of a grid of points were obtained. Using this system, a three dimensional scaled image of the implant could be created and was used to calculate the total penetration of the femoral condyle due to true wear and creep. Total linear penetration rates ranged from 0.18 to 2.6 millimeters per year (mean 0.25 millimeters per year). Linear penetration rates due to true wear ranged from 0.08 to 1.4 millimeters per year (mean 0.13 millimeter per year), and penetration due to creep ranged from 0.07 to 1.9 millimeters per year (mean 0.12 millimeters per year). The linear and volumetric penetration rates of the femoral condyle due to true wear were negatively correlated with the duration of implantation. The linear penetration rate due to creep was higher in the first two years after the implantation compared to the subsequent years. Using multiple linear regression analyses to remove the confounding effects of age, weight, gender and thickness of the implant, we found that an increase of the postoperative varus deformity was due to an increase of creep (p = 0.03) but not with an increase of true wear (p = 0.25). Thinner implants were due to an increase of creep (p = 0.02) but not with an increase of true wear (p = 0.34). Increase in age was in relation with decrease of wear (p = 0.02) and increase of weight with increase in creep (p = 0.03). Plastic deformation had a high influence on the penetration rate of the femoral condyle in full polyethylene implants. There is a risk of an increased penetration and a decrease of the remaining thickness of the tibial plateau when the implant is too thin, the knee mal-aligned and the patient heavy - each of these factors increasing the creep deformation. In conclusion, our study suggests that surgeons using the Lotus Mk I unicompartmental knee replacement for medial tibiofemoral arthritis should beware of the overweight patient (>90kg) with a tibial implant of less than 9 mm. There is a risk of increased penetration and decreased thickness of the tibial implant when it is too thin, the knee malaligned, and the patient heavy. All these factors increase creep deformation.
[1]
W. Harris,et al.
Metrology to Quantify Wear and Creep of Polyethylene Tibial Knee Inserts
,
2003,
Clinical orthopaedics and related research.
[2]
John M. Kelly.
ULTRA-HIGH MOLECULAR WEIGHT POLYETHYLENE*
,
2002
.
[3]
D. Ammeen,et al.
Revision of Failed Unicompartmental Knee Arthroplasty
,
2001,
Clinical orthopaedics and related research.
[4]
J O Galante,et al.
Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty.
,
1994,
Clinical orthopaedics and related research.
[5]
R. Wixson,et al.
Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces.
,
1994,
Clinical orthopaedics and related research.
[6]
S. Stulberg,et al.
Polyethylene wear in unicompartmental knee arthroplasty.
,
1994,
Clinical orthopaedics and related research.
[7]
J. Rand,et al.
Revision of failed unicompartmental total knee arthroplasty.
,
1993,
Clinical orthopaedics and related research.
[8]
A. Lindstrand,et al.
Polyethylene wear of the PCA unicompartmental knee. Prospective 5 (4-8) year study of 120 arthrosis knees.
,
1992,
Acta orthopaedica Scandinavica.
[9]
L Ryd,et al.
Polyethylene wear in unicondylar knee prostheses. 106 retrieved Marmor, PCA, and St Georg tibial components compared.
,
1992,
Acta orthopaedica Scandinavica.
[10]
E. Morscher,et al.
[Failures of knee joint prostheses. An analysis of knee prostheses and component revisions, 1980-1987].
,
1991,
Der Orthopade.
[11]
D. Bartel,et al.
The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement.
,
1986,
The Journal of bone and joint surgery. American volume.
[12]
A H Burstein,et al.
Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses.
,
1983,
Journal of biomedical materials research.