Practice and potential pitfalls of coronary pressure measurement

Guidewire‐based coronary pressure measurement has emerged over the last years as a promising approach in the invasive assessment of coronary artery disease. It enables calculation of fractional flow reserve (FFR) which closely relates distal coronary pressure to myocardial blood flow during maximal arteriolar vasodilation. Coronary pressure measurement and FFR provide important information, both for decision making in diagnostic angiography and for monitoring and evaluating coronary interventions. In this review, the practical set‐up of coronary pressure measurement in the catheterization laboratory is discussed step‐by‐step, special attention is given to potential pitfalls and how to avoid them, and the interpretation of coronary pressure measurement in a variety of pathologic conditions is clarified. Cathet. Cardiovasc. Intervent. 49:1–16, 2000. © 2000 Wiley‐Liss, Inc.

[1]  J. Koolen,et al.  Comparison of quantitative coronary angiography, intravascular ultrasound, and coronary pressure measurement to assess optimum stent deployment. , 1999, Circulation.

[2]  M. Menegus,et al.  Fractional Flow Reserve , 1997 .

[3]  R. Wilson,et al.  Effects of adenosine on human coronary arterial circulation. , 1990, Circulation.

[4]  N. Pijls,et al.  Fractional Flow Reserve , 1995 .

[5]  B. De Bruyne,et al.  Coronary pressure measurement and fractional flow reserve , 1998, Heart.

[6]  M. Kern,et al.  Intravenous adenosine: continuous infusion and low dose bolus administration for determination of coronary vasodilator reserve in patients with and without coronary artery disease. , 1991, Journal of the American College of Cardiology.

[7]  M. Miyagawa,et al.  Thallium-201 myocardial tomography with intravenous infusion of adenosine triphosphate in diagnosis of coronary artery disease. , 1995, Journal of the American College of Cardiology.

[8]  J. Bartunek,et al.  Relation between myocardial fractional flow reserve calculated from coronary pressure measurements and exercise-induced myocardial ischemia. , 1995, Circulation.

[9]  R. Peters,et al.  Clinical, angiographic and hemodynamic predictors of recruitable collateral flow assessed during balloon angioplasty coronary occlusion. , 1997, Journal of the American College of Cardiology.

[10]  R. Wilson,et al.  Assessing the severity of coronary-artery stenoses. , 1996, The New England journal of medicine.

[11]  P. H. van der Voort,et al.  Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses. , 1996, The New England journal of medicine.

[12]  W. Rutishauser,et al.  Potential protective effect of high coronary wedge pressure on left ventricular function after coronary occlusion. , 1988, Circulation.

[13]  J. Hoffman Maximal coronary flow and the concept of coronary vascular reserve. , 1984, Circulation.

[14]  M. Kern,et al.  From research to clinical practice: current role of intracoronary physiologically based decision making in the cardiac catheterization laboratory. , 1997, Journal of the American College of Cardiology.

[15]  J. Bech,et al.  Comparison of intravenous adenosine to intracoronary papaverine for calculation of pressure-derived fractional flow reserve. , 1996, Catheterization and Cardiovascular Diagnosis.

[16]  B. De Bruyne,et al.  Role of side holes in guide catheters: observations on coronary pressure and flow. , 1994, Catheterization and cardiovascular diagnosis.

[17]  P. H. van der Voort,et al.  Fractional flow reserve. A useful index to evaluate the influence of an epicardial coronary stenosis on myocardial blood flow. , 1995, Circulation.

[18]  W. Wijns,et al.  Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve. , 1996, Circulation.

[19]  J. Koolen,et al.  Usefulness of fractional flow reserve to predict clinical outcome after balloon angioplasty. , 1999, Circulation.

[20]  R. Wilson,et al.  Intracoronary papaverine: an ideal coronary vasodilator for studies of the coronary circulation in conscious humans. , 1986, Circulation.

[21]  J. Koolen,et al.  Quantification of recruitable coronary collateral blood flow in conscious humans and its potential to predict future ischemic events. , 1995, Journal of the American College of Cardiology.

[22]  B. De Bruyne,et al.  Experimental Basis of Determining Maximum Coronary, Myocardial, and Collateral Blood Flow by Pressure Measurements for Assessing Functional Stenosis Severity Before and After Percutaneous Transluminal Coronary Angioplasty , 1993, Circulation.

[23]  H. Gewirtz Fractional flow reserve. , 1996, Circulation.

[24]  R. Kerber,et al.  Effects of cardiac hypertrophy secondary to hypertension on the coronary circulation. , 1979, The American journal of cardiology.

[25]  A Bol,et al.  Coronary flow reserve calculated from pressure measurements in humans. Validation with positron emission tomography. , 1994, Circulation.

[26]  E. Nabel,et al.  Dilation of normal and constriction of atherosclerotic coronary arteries caused by the cold pressor test. , 1988, Circulation.