Analytical tools to assess the voltage stability of induction-based distributed generators

The installation of induction distributed generators should be preceded by a careful study in order to determine if the point of common coupling is suitable for transmission of the generated power, keeping acceptable power quality and system stability. In this sense, this paper presents a simple analytical formulation that allows a fast and comprehensive evaluation of the maximum power delivered by the induction generator, without losing voltage stability. Moreover, this formulation can be used to identify voltage stability issues that limit the generator output power. All the formulation is developed by using the equivalent circuit of squirrel-cage induction machine. Simulation results are used to validate the method, which enables the approach to be used as a guide to reduce the simulation efforts necessary to assess the maximum output power and voltage stability of induction generators.

[1]  Siegfried Heier,et al.  Grid Integration of Wind Energy Conversion Systems , 1998 .

[2]  John R. Parsons Cogeneration Application of Induction Generators , 1984, IEEE Transactions on Industry Applications.

[3]  O. Samuelsson,et al.  On speed stability , 2005, IEEE Transactions on Power Systems.

[4]  D.J. Trudnowski,et al.  Fixed-speed wind-generator and wind-park modeling for transient stability studies , 2004, IEEE Transactions on Power Systems.

[5]  Jizhong Zhu,et al.  Analysis of Voltage Stability in a Practical Power System with Wind Power , 2010 .

[6]  Tomonobu Senjyu,et al.  Optimal voltage control in distribution systems using PV generators , 2011 .

[7]  J. K. Chatterjee,et al.  Three-Phase Induction Generators: A Discussion on Performance , 1999 .

[8]  Antonio Moreno-Munoz,et al.  Improvement of power quality using distributed generation , 2010 .

[9]  S. K. Salman,et al.  Windmill modelling consideration and factors influencing the stability of a grid-connected wind power based embedded generator , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[10]  Tadeusz Lobos,et al.  Application of wavelets and Prony method for disturbance detection in fixed speed wind farms , 2009 .

[11]  S. Williamson,et al.  Transient electrical and mechanical behaviour of large induction generator installations , 1989 .

[12]  Jiaqi Liang,et al.  Effects of variable solar irradiance on the reactive power compensation for large solar farm , 2010, 2010 IREP Symposium Bulk Power System Dynamics and Control - VIII (IREP).

[13]  H. L. Nakra,et al.  Case study on the integration of a non-utility induction generator to the Hydro-Quebec distribution network , 1995 .

[14]  Thomas Ackermann,et al.  Wind Power in Power Systems , 2005 .

[15]  Julio Usaola,et al.  Incidence on Power System Dynamics of High Penetration of Fixed Speed and Doubly Fed Wind Energy Systems: Study of the Spanish Case , 2002, IEEE Power Engineering Review.

[16]  S. K. Salman,et al.  Windmill modeling consideration and factors influencing the stability of a grid-connected wind power-based embedded generator , 2002 .

[17]  Julio Usaola,et al.  Transient stability of a fixed speed wind farm , 2003 .

[18]  P. Kundur,et al.  Power system stability and control , 1994 .

[19]  M. A. Pai,et al.  A sensitivity-based approach for studying stability impact of distributed generation , 2008 .

[20]  W. Freitas,et al.  An Analytical Method for Analysis of Large-Disturbance Stability of Induction Generators , 2007, IEEE Transactions on Power Systems.

[21]  W. Freitas,et al.  Small-disturbance voltage stability of distribution systems with induction generators , 2005, IEEE Transactions on Power Systems.

[22]  K. C. Divya,et al.  Effect of Grid Voltage and Frequency Variations on the Output of Wind Generators , 2008 .

[23]  Vladislav Akhmatov System stability of large wind power networks: A Danish study case , 2006 .