Current Loop Control with Admittance Compensation for a Single-Phase Grid-Tie Fuel Cell Power Conditioning System

Current loop transfer function of a single-phase grid-tie inverter has been systematically derived with representations of conventional transfer function format and admittance terms for the sake of controller design and feed-forward compensation. A 5 kW grid-tie fuel cell power conditioning system (PCS) example is used in paper to show current loop controller design and admittance compensation technique. A second order lead-lag compensator is proposed to avoid low stability margin while maintaining sufficient gain at the fundamental frequency. The proposed current loop controller and admittance compensation have been simulated, and the same parameters have been used for a DSP-based PCS inverter controller. Simulation results indicate that without the admittance path compensation, the duty cycle of the current loop controller is largely offset by the admittance path. At light load settings, the power flow may be erratically fed back to the inverter that can cause dc bus over voltage and subsequently a catastrophe failure. With admittance path compensation and the designed lead-lag compensator, the output power shows a steady-state offset that coincidently is required by the fuel cell. Experimental results well matched the mathematical design and simulation results.

[1]  Richard S. Zhang,et al.  A grid simulator with control of single-phase power converters in D-Q rotating frame , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[2]  Yukihiko Sato,et al.  A new control strategy for voltage type PWM rectifiers to realise zero steady-state control error in input current , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[3]  M. Liserre,et al.  A new control structure for grid-connected LCL PV inverters with zero steady-state error and selective harmonic compensation , 2004, Nineteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2004. APEC '04..

[4]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady state error , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[5]  Remus Teodorescu,et al.  A New Single-Phase PLL Structure Based on Second Order Generalized Integrator , 2006 .

[6]  S.M. Silva,et al.  PLL structures for utility connected systems , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[7]  Rae-Young Kim,et al.  Instantaneous control of average power for grid tie inverter using single phase D-Q rotating frame with all pass filter , 2004, 30th Annual Conference of IEEE Industrial Electronics Society, 2004. IECON 2004.

[8]  Poh Chiang Loh,et al.  Analysis of multiloop control strategies for LC/CL/LCL-filtered voltage-source and current-source inverters , 2005, IEEE Transactions on Industry Applications.

[9]  Jih-Sheng Lai,et al.  Current Phase Lead Compensation in Single-Phase PFC Boost Converters With a Reduced Switching Frequency to Line Frequency Ratio , 2007 .