A comprehensive review for optimal placement of phasor measurement unit for network observability

Real time synchronized phasor measurement in power network is obtained by the improvement in monitoring, control and, protection of the power system. In recent time, the installation ratio of Phasor Measurement Units (PMUs) is constantly increasing for the real time measurement throughout worldwide. The increment in the number of PMU installation is to only focus on the improvement of system state estimation (SE) performance. However, the expensive nature of the metering device requires huge amount of installation cost with the other communication facilities, therefore an optimal placement of PMU is necessary. Different techniques have been designed and used to overcome this matter. The paper presents numerous optimization algorithms such as, Mathematical programming, Heuristic, and Meta-Heuristic techniques which are specially used for the optimization of PMU placement with complete network observability. Furthermore, each PMU technique is explained, and performances are compared for the most appropriate and optimal placement of PMU methods, which can be recommended for a future work to get complete network observability.

[1]  Chi Su,et al.  Optimal Placement of Phasor Measurement Units with New Considerations , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[2]  A.M. Glazunova,et al.  PMU placement on the basis of SCADA measurements for fast load flow calculation in electric power systems , 2009, 2009 IEEE Bucharest PowerTech.

[3]  A. Abur,et al.  Placement of PMUs to Enable Bad Data Detection in State Estimation , 2006, IEEE Transactions on Power Systems.

[4]  Qian Ai,et al.  Research of PMU optimal placement in power systems , 2005 .

[5]  B. Gou,et al.  Generalized Integer Linear Programming Formulation for Optimal PMU Placement , 2008, IEEE Transactions on Power Systems.

[6]  I. O. Habiballah,et al.  Optimization of Phasor Measurement Unit (PMU) Placement in Supervisory Control and Data Acquisition (SCADA)-Based Power System for Better State-Estimation Performance , 2018 .

[7]  Li Ying,et al.  Sensitivity Constrained PMU Placement for Complete Observability of Power Systems , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[8]  M. Farsadi,et al.  Phasor Measurement Unit (PMU) allocation in power system with different algorithms , 2009, 2009 International Conference on Electrical and Electronics Engineering - ELECO 2009.

[9]  A.G. Phadke,et al.  Phasor measurement unit placement techniques for complete and incomplete observability , 2005, IEEE Transactions on Power Delivery.

[10]  Joong-Rin Shin,et al.  Optimal placement of phasor measurement units with GPS receiver , 2001, 2001 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.01CH37194).

[11]  A.M. Ranjbar,et al.  Optimal Placement of Phasor Measurement Units: Particle Swarm Optimization Approach , 2007, 2007 International Conference on Intelligent Systems Applications to Power Systems.

[12]  A.G. Phadke,et al.  A preprocessing method for effective PMU placement studies , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[13]  Francisco Sandoval Hernández,et al.  Optimal Phasor Measurement Unit Placement Using Genetic Algorithms , 2003, IWANN.

[14]  Ovidiu Ivanov,et al.  SYNCHRONIZED PHASOR MEASUREMENTS FOR STATE ESTIMATION , 2009 .

[15]  Mario Paolone,et al.  A Synchrophasor Estimation Algorithm for the Monitoring of Active Distribution Networks in Steady State and Transient Conditions , 2011 .

[16]  Demetrios G. Eliades,et al.  Placement of Synchronized Measurements for Power System Observability , 2009, IEEE Transactions on Power Delivery.

[17]  Elias Kyriakides,et al.  Uncertainty in Power System State Variables Obtained Through Synchronized Measurements , 2009, IEEE Transactions on Instrumentation and Measurement.

[18]  C. Mishra Modelling of Phasor Measurement Unit and Phasor Data Realisation with 2 Bus System , 2015 .

[19]  Yi Yang,et al.  Engineering practical method for PMU placement of 2010 Yunnan power grid in China , 2009, 2009 International Conference on Sustainable Power Generation and Supply.

[20]  A.Z. Gamm,et al.  PMU placement criteria for EPS state estimation , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[21]  Muhammad Aamir,et al.  Modeling and simulation of phasor measurement unit (PMU) for early fault detection in interconnected two-area network , 2018, 2018 1st International Conference on Power, Energy and Smart Grid (ICPESG).

[22]  Ali Abur,et al.  OPTIMAL PLACEMENT AND UTILIZATION OF PHASOR MEASUREMENTS FOR STATE ESTIMATION , 2005 .

[23]  Weng Khuen Ho,et al.  Optimum Placement of Phasor Measurement Units in Power Systems , 2019, IEEE Transactions on Instrumentation and Measurement.

[24]  Dong Liu,et al.  Optimal placement of PMUs in power systems based on improved PSO algorithm , 2008, 2008 3rd IEEE Conference on Industrial Electronics and Applications.

[25]  Sukumar Brahma,et al.  Optimal PMU placement for fault location in a power system , 2009, 41st North American Power Symposium.

[26]  M. Robert Aaron,et al.  B70-3 Analog-to-Digital and Digital-to-Analog Conversion Techniques , 1970, IEEE Transactions on Computers.