Effects of toe stiffness on ankle kinetics in a robotic transtibial prosthesis during level-ground walking

Abstract Robotic transtibial prostheses are gaining popularity, as they significantly improve amputees’ locomotion. Existing studies mainly concentrate on the importance of ankle joints in these prostheses. However, there are few studies that focus on the effects of prosthetic toe joints. Different from human feet, most prosthetic feet are single-segment structures without toe joints. In order to develop more human-like prostheses with ankle and toe joints, it is of great importance to investigate the effects of toe stiffness on ankle kinetics, as it contributes to the design and control optimizations. In this paper, we analyze the effects of toe stiffness on ankle kinetics in a robotic transtibial prosthesis we have built recently. Dynamic models of the prosthesis’ ankle and toe joints are built. The imposed plantar pressures and objective joint angles of these models are obtained from locomotion experiments on able-bodied subjects. Simulation results indicate when the toe joint is fixed, the ankle energy consumption in one gait cycle is almost 1.2 times of that when the toe joint is driven to track the able-bodied toe motion. Experiments of the prosthesis prototype are carried out on an amputee subject with a transtibial amputation. The results show that compared with the fixed toe joint either the active toe joint or the passive toe joint can reduce the ankle output moment and power consumption. This means adding a toe joint to the foot can reduce the designing requirements of the ankle joint. In addition, the active toe joint can help the prosthesis perform more human-like behaviors compared with the passive toe joint. On the other hand, the passive toe joint can simplify the prosthesis structures and reduce the total weight compared with the active toe joint.

[1]  Nevio Luigi Tagliamonte,et al.  Double actuation architectures for rendering variable impedance in compliant robots: A review , 2012 .

[2]  H. Ulbrich,et al.  System Design and Control of Anthropomorphic Walking Robot LOLA , 2009, IEEE/ASME Transactions on Mechatronics.

[3]  Bram Vanderborght,et al.  A biomechatronical transtibial prosthesis powered by pleated pneumatic artificial muscles , 2008, Int. J. Model. Identif. Control..

[4]  Masayuki Inaba,et al.  Toe joints that enhance bipedal and fullbody motion of humanoid robots , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[5]  Atsuo Takanishi,et al.  Human-like walking with knee stretched, heel-contact and toe-off motion by a humanoid robot , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[6]  H. Grootenboer,et al.  Stiffness and hysteresis properties of some prosthetic feet , 1990, Prosthetics and orthotics international.

[7]  Shuuji Kajita,et al.  ZMP-based Biped Running Enhanced by Toe Springs , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[8]  Thomas Sugar,et al.  Robotic transtibial prosthesis with biomechanical energy regeneration , 2009, Ind. Robot.

[9]  John H Challis,et al.  An objective evaluation of a segmented foot model. , 2009, Gait & posture.

[10]  R. Marks,et al.  Validation of a multisegment foot and ankle kinematic model for pediatric gait , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[11]  S. Miyazaki,et al.  Moment acting at the metatarsophalangeal joints during normal barefoot level walking , 1993 .

[12]  Hugh M. Herr,et al.  Powered Ankle--Foot Prosthesis Improves Walking Metabolic Economy , 2009, IEEE Transactions on Robotics.

[13]  B. MacWilliams,et al.  Foot kinematics and kinetics during adolescent gait. , 2003, Gait & posture.

[14]  Bram Vanderborght,et al.  Design and Validation of the Ankle Mimicking Prosthetic (AMP-) Foot 2.0 , 2014, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[15]  Rocco Vertechy,et al.  Smart Actuation and Sensing Systems - Recent Advances and Future Challenges , 2012 .

[16]  J J O'Connor,et al.  Kinematic analysis of a multi-segment foot model for research and clinical applications: a repeatability analysis. , 2001, Journal of biomechanics.

[17]  Nicola Vitiello,et al.  A sensorless torque control for Antagonistic Driven Compliant Joints , 2010 .

[18]  Guangming Xie,et al.  Modeling and analysis of passive dynamic bipedal walking with segmented feet and compliant joints , 2012 .

[19]  Stefania Fatone,et al.  Biomechanics of Ambulation After Partial Foot Amputation: A Systematic Literature Review , 2007 .

[20]  Long Wang,et al.  Segmented Foot with Compliant Actuators and Its Applications to Lower-Limb Prostheses and Exoskeletons , 2012 .

[21]  Jongsang Son,et al.  Kinetic role of the metatarsophalangeal joint in normal walking: Joint moment and power , 2012 .

[22]  J. van den Berg,et al.  Calf muscle moment, work and efficiency in level walking; role of series elasticity. , 1983, Journal of biomechanics.

[23]  Long Wang,et al.  On the Design of a Powered Transtibial Prosthesis With Stiffness Adaptable Ankle and Toe Joints , 2014, IEEE Transactions on Industrial Electronics.

[24]  Jungwon Yoon,et al.  A novel dynamic walker with heel, ankle, and toe rocker motions , 2011, Robotica.

[25]  Alena M. Grabowski,et al.  Effects of a powered ankle-foot prosthesis on kinetic loading of the unaffected leg during level-ground walking , 2013, Journal of NeuroEngineering and Rehabilitation.

[26]  Long Wang,et al.  Adding segmented feet to passive dynamic walkers , 2010, 2010 IEEE/ASME International Conference on Advanced Intelligent Mechatronics.

[27]  Blake Hannaford,et al.  Muscle-Like Pneumatic Actuators for Below-Knee Prostheses, , 2000 .

[28]  Long Wang,et al.  PANTOE 1: Biomechanical design of powered ankle-foot prosthesis with compliant joints and segmented foot , 2010, 2010 IEEE/ASME International Conference on Advanced Intelligent Mechatronics.

[29]  D. Winter Energy generation and absorption at the ankle and knee during fast, natural, and slow cadences. , 1983, Clinical orthopaedics and related research.