Comprehensive Dynamic Contrast-Enhanced 3D Magnetic Resonance Imaging of the Breast With Fat/Water Separation and High Spatiotemporal Resolution Using Radial Sampling, Compressed Sensing, and Parallel Imaging
暂无分享,去创建一个
Linda Moy | Daniel K. Sodickson | Kai Tobias Block | Samantha Heller | Thomas Benkert | Melanie Moccaldi | Sungheon Gene Kim | K. T. Block | D. Sodickson | L. Moy | M. Moccaldi | T. Benkert | S. Kim | S. Heller
[1] Håkan Ahlström,et al. Three‐point dixon method enables whole‐body water and fat imaging of obese subjects , 2010, Magnetic resonance in medicine.
[2] R. R. Ernst,et al. Application of Fourier Transform Spectroscopy to Magnetic Resonance , 1966 .
[3] Ricardo Otazo,et al. Comparison of conventional DCE‐MRI and a novel golden‐angle radial multicoil compressed sensing method for the evaluation of breast lesion conspicuity , 2017, Journal of magnetic resonance imaging : JMRI.
[4] Sungheon Kim,et al. Golden‐angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden‐angle radial sampling for fast and flexible dynamic volumetric MRI , 2014, Magnetic resonance in medicine.
[5] G H Glover,et al. Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction , 1991, Magnetic resonance in medicine.
[6] Ryan J Bosca,et al. Novel High Spatiotemporal Resolution Versus Standard-of-Care Dynamic Contrast-Enhanced Breast MRI: Comparison of Image Quality , 2017, Investigative radiology.
[7] Wei Huang,et al. A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings. , 2012, Magnetic resonance imaging.
[8] Guangbin Wang,et al. Influence of scan duration on the estimation of pharmacokinetic parameters for breast lesions: a study based on CAIPIRINHA-Dixon-TWIST-VIBE technique , 2015, European Radiology.
[9] Jeffrey A. Fessler,et al. Nonuniform fast Fourier transforms using min-max interpolation , 2003, IEEE Trans. Signal Process..
[10] Qun Chen,et al. Optimal k‐space sampling for dynamic contrast‐enhanced MRI with an application to MR renography , 2009, Magnetic resonance in medicine.
[11] S. Schoenberg,et al. Feasibility of Gadofosveset-Enhanced Steady-State Magnetic Resonance Angiography of the Peripheral Vessels at 3 Tesla With Dixon Fat Saturation , 2008, Investigative radiology.
[12] Hans H Schild,et al. Dynamic bilateral contrast-enhanced MR imaging of the breast: trade-off between spatial and temporal resolution. , 2005, Radiology.
[13] Yuan Le,et al. Development and evaluation of TWIST Dixon for dynamic contrast‐enhanced (DCE) MRI with improved acquisition efficiency and fat suppression , 2012, Journal of magnetic resonance imaging : JMRI.
[14] Olaf Dössel,et al. An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRI , 2007, IEEE Transactions on Medical Imaging.
[15] Peter Boesiger,et al. Array compression for MRI with large coil arrays , 2007, Magnetic resonance in medicine.
[16] C. Geppert,et al. Application of time‐resolved angiography with stochastic trajectories (twist)‐dixon in dynamic contrast‐enhanced (dce) breast mri , 2013, Journal of magnetic resonance imaging : JMRI.
[17] Daniel K. Sodickson,et al. Towards Routine Clinical Use of Radial Stack-of-Stars 3D Gradient-Echo Sequences for Reducing Motion Sensitivity , 2014 .
[18] S. Schoenberg,et al. Clinical application of 3D VIBECAIPI-DIXON for non-enhanced imaging of the pancreas compared to a standard 2D fat-saturated FLASH. , 2014, Clinical imaging.
[19] M. Lustig,et al. Compressed sensing for chemical shift‐based water–fat separation , 2010, Magnetic resonance in medicine.
[20] Wendy B DeMartini,et al. A Review of Current Evidence-Based Clinical Applications for Breast Magnetic Resonance Imaging , 2008, Topics in magnetic resonance imaging : TMRI.
[21] Li Feng,et al. Influence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast , 2016, Journal of magnetic resonance imaging : JMRI.
[22] Nico Karssemeijer,et al. A Novel Approach to Contrast-Enhanced Breast Magnetic Resonance Imaging for Screening: High-Resolution Ultrafast Dynamic Imaging , 2014, Investigative radiology.
[23] Li Feng,et al. Free‐breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging , 2017, Magnetic resonance in medicine.
[24] Peter Börnert,et al. Chemical shift encoding‐based water–fat separation methods , 2014, Journal of magnetic resonance imaging : JMRI.
[25] K. T. Block,et al. Simple Method for Adaptive Gradient-Delay Compensation in Radial MRI , 2010 .
[26] K. Pinker,et al. Fat saturation in dynamic breast MRI at 3 Tesla: is the Dixon technique superior to spectral fat saturation? A visual grading characteristics study , 2014, European Radiology.