A novel fluorescence-based array biosensor: principle and application to DNA hybridization assays.

A novel fluorescence-based array biosensor targeted for field applications, such as environmental monitoring, has been developed, and successfully applied to DNA hybridization assays. The purpose was to meet the demand for automated, portable but easy-to-maintain systems allowing continuous flow monitoring of surface reactions. The biosensor presented here can be distinguished from the existing systems by the optical method used, which provides an enhanced simplicity and robustness, and enables a simple maintenance by potentially unskilled personnel. The system is based on a conventional microscope slide which acts both as transducer and biological array sensor. The excited fluorescence is guided by total internal reflection into the slide to the detector which is directly interfaced to the slide. Each region of the sensor array is successively optically interrogated, and the detection of the corresponding fluorescent emission synchronized. A real-time three-analyte analysis is thus feasible without any mechanical scanning movement or optical imaging systems as generally used in the existing instruments. The ability of the biosensor to operate in continuous flow for several tens of hours has been demonstrated. The biosensor has been assessed in terms of stability, and slide-to-slide reproducibility, which is found to be less than 3.7%, thus far below the standard biological reproducibility. DNA hybridization assays were performed to estimate a limit of detection, which was found to be 16 mol/microm(2), and to determine the reaction kinetics associated to the DNA model used. The developed biosensor is thus shown to be able to predict reaction kinetics, and to monitor in real time surface reactions between targets and probes.

[1]  J. Grassi,et al.  Solid-phase immobilized tripod for fluorescent renewable immunoassay. A concept for continuous monitoring of an immunoassay including a regeneration of the solid phase. , 2005, Analytical chemistry.

[2]  David G Myszka,et al.  Characterizing high-affinity antigen/antibody complexes by kinetic- and equilibrium-based methods. , 2004, Analytical biochemistry.

[3]  L. Christensen Theoretical analysis of protein concentration determination using biosensor technology under conditions of partial mass transport limitation. , 1997, Analytical biochemistry.

[4]  R. Karlsson,et al.  Analysis of active antibody concentration. Separation of affinity and concentration parameters. , 1993, Journal of immunological methods.

[5]  A M Smith,et al.  Optical biosensors for immunoassays: the fluorescence capillary-fill device. , 1987, Philosophical transactions of the Royal Society of London. Series B, Biological sciences.

[6]  Frédéric Ginot,et al.  Opto-electronic DNA chip: high performance chip reading with an all-electric interface. , 2005, Biosensors & bioelectronics.

[7]  Brian D. MacCraith,et al.  Fluorescence capture by planar waveguide as platform for optical sensors , 1998 .

[8]  Mingde Zhu,et al.  Kinetic analysis of a high-affinity antibody/antigen interaction performed by multiple Biacore users. , 2006, Analytical biochemistry.

[9]  Konstantinos Misiakos,et al.  A monolithic silicon optoelectronic transducer as a real-time affinity biosensor. , 2004, Analytical chemistry.

[10]  Pieter Stroeve,et al.  Convection, diffusion and reaction in a surface-based biosensor: modeling of cooperativity and binding site competition on the surface and in the hydrogel. , 2006, Journal of colloid and interface science.

[11]  M. Ericson,et al.  DNA biochip using a phototransistor integrated circuit. , 1999, Analytical chemistry.

[12]  R. Reich,et al.  A microchip for quantitative detection of molecules utilizing luminescent and radioisotope reporter groups. , 1994, BioTechniques.

[13]  D E Leckband,et al.  A computational reaction-diffusion model for the analysis of transport-limited kinetics. , 1999, Analytical chemistry.

[14]  A. Page,et al.  An assay for human chorionic gonadotrophin using the capillary fill immunosensor. , 1991, Biosensors & bioelectronics.

[15]  Peter Oswald,et al.  Automated Water Analyser Computer Supported System (AWACSS) Part II: Intelligent, remote-controlled, cost-effective, on-line, water-monitoring measurement system. , 2005, Biosensors & bioelectronics.

[16]  G Gauglitz,et al.  Simultaneous multi-analyte determination of estrone, isoproturon and atrazine in natural waters by the RIver ANAlyser (RIANA), an optical immunosensor. , 2004, Biosensors & bioelectronics.

[17]  Francesco Baldini,et al.  Optical chemical and biochemical sensors: new trends (Invited Paper) , 2005, SPIE OPTO-Ireland.

[18]  Chris A. Rowe-Taitt,et al.  Array biosensor for detection of biohazards. , 2000, Biosensors & bioelectronics.

[19]  D G Myszka,et al.  Extending the range of rate constants available from BIACORE: interpreting mass transport-influenced binding data. , 1998, Biophysical journal.

[20]  Tuan Vo-Dinh,et al.  FRET-based protein–DNA binding assay for detection of active NF-κB , 2006 .

[21]  David G Myszka,et al.  Screening antibody-antigen interactions in parallel using Biacore A100. , 2006, Analytical biochemistry.

[22]  F. Ligler,et al.  Continuous flow displacement immunosensors: a computational study. , 2000, Analytical biochemistry.

[23]  Reinhard Niessner,et al.  Highly parallel affinity sensor for the detection of environmental contaminants in water , 1999 .

[24]  Timothy Bacarese-Hamilton,et al.  Fluorescent capillary fill device: a quantitative whole-blood assay system suited to point-of-care use , 1998, Photonics West - Biomedical Optics.

[25]  J. Lambe,et al.  Luminescent greenhouse collector for solar radiation. , 1976, Applied optics.

[26]  G. Anderson,et al.  Multi-analyte interrogation using the fiber optic biosensor. , 2000, Biosensors & bioelectronics.

[27]  F. Ligler,et al.  Array Biosensor: Optical and Fluidics Systems , 1999, Biomedical microdevices.