Morphological changes during early trans-tibial prosthetic fitting

Morphological changes in the amputation stump may have serious implications regarding the suspension and fit of the prosthetic socket. In an earlier study (Lilja and Öberg, 1997) the authors have shown that the volume of the transtibial amputation stump decreases according to a negative power function after amputation, and that the stump volume does not stabilise until four months after the operation. In the present study, Magnetic Resonance Imaging (MRI) technique was used to examine morphological changes in the amputation stump after transtibial amputation in a small number of cases. The authors expected to find a decrease in the cross-sectional area of the stump and of the separate muscles similar to the findings in earlier studies. However, two different patterns were found. The cross-sectional area of the entire stump as well as that of the medial muscle group changed according to the authors' hypothesis, i.e. an initial fast decrease, followed by a more moderate decrease of the area. In the lateral muscle group another pattern was found. After an initial rapid decrease the area increased, sometimes to a magnitude larger than the initial value. After the amputation the lateral muscle group may acquire a new function, contributing to the suspension of the socket. Despite the limited number of patients, this study presents findings which may be important in the clinical fitting of trans-tibial prostheses.

[1]  J. D. Morrison,et al.  Rehabilitation outcome 5 years after 100 lower‐limb amputations , 1994, The British journal of surgery.

[2]  S. Levy Skin problems of the leg amputee , 1980, Archives of dermatology.

[3]  M. Eneroth Amputation for vascular disease. Prognostic factors for healing, long-term outcome and costs. , 1997 .

[4]  Magnus Lilija,et al.  Proper Time for Definitive Transtibial Prosthetic Fitting , 1997 .

[5]  • Epidermis,et al.  WOUND healing. , 1959, The Medical journal of Australia.

[6]  P. McCollum,et al.  Rehabilitation outcome 5 years after 100 lower limb amputations , 1995, The British journal of surgery.

[7]  R L Lieber,et al.  Volume changes occurring in postoperative below-knee residual limbs. , 1988, Journal of rehabilitation research and development.

[8]  T M Cutson,et al.  Rehabilitation of the Older Lower Limb Amputee: A Brief Review , 1996, Journal of the American Geriatrics Society.

[9]  K. Angquist,et al.  Fibre loss and distribution in skeletal muscle from patients with severe peripheral arterial insufficiency. , 1989, European journal of vascular surgery.

[10]  S W Levy,et al.  Skin problems of the leg amputee. , 1980, Prosthetics and orthotics international.

[11]  E M Burgess,et al.  Effects of isometric muscle training on residual limb volume, strength, and gait of below-knee amputees. , 1981, Physical therapy.

[12]  James W. Breakey,et al.  Body Image: The Lower‐Limb Amputee , 1997 .

[13]  J. Ekholm,et al.  Quantified electromyography of lower-limb muscles during level walking. , 2020, Scandinavian journal of rehabilitation medicine.

[14]  S. Levy Disabling skin reactions associated with stump edema. , 1977, International journal of dermatology.

[15]  H. Alaranta,et al.  Lower limb amputees in Southern Finland , 1995, Prosthetics and orthotics international.

[16]  Electromyographic study of muscular activity in the amputation stump while walking with PTB- and PTB-suction prosthesis. , 1975, Upsala journal of medical sciences.

[17]  G. Fick,et al.  The effect of semirigid dressings on below-knee amputations. , 1994, Physical therapy.

[18]  R. Baumgartner,et al.  Amputee stump radiology , 1980, Prosthetics and orthotics international.

[19]  K. Manella,et al.  Comparing the effectiveness of elastic bandages and shrinker socks for lower extremity amputees. , 1981, Physical therapy.

[20]  G Grimby,et al.  Thigh muscle atrophy in below-knee amputees. , 1983, Scandinavian journal of rehabilitation medicine. Supplement.