A method to reduce the Gibbs ringing artifact in MRI scans while keeping tissue boundary integrity

Gibbs ringing is a well known artifact that effects reconstruction of images having discontinuities. This is a problem in the reconstruction of magnetic resonance imaging (MRI) data due to the many different tissues normally present in each scan. The Gibbs ringing artifact manifests itself at the boundaries of the tissues, making it difficult to determine the structure of the brain tissue. The Gegenbauer reconstruction method has been shown to effectively eliminate the effects of Gibbs ringing in other applications. This paper presents the application of the Gegenbauer reconstruction method to neuro-imaging.

[1]  Anne Gelb,et al.  Detection of Edges in Spectral Data II. Nonlinear Enhancement , 2000, SIAM J. Numer. Anal..

[2]  Alan C. Evans,et al.  BrainWeb: Online Interface to a 3D MRI Simulated Brain Database , 1997 .

[3]  Anne Gelb,et al.  A Hybrid Approach to Spectral Reconstruction of Piecewise Smooth Functions , 2000, J. Sci. Comput..

[4]  D. Louis Collins,et al.  Design and construction of a realistic digital brain phantom , 1998, IEEE Transactions on Medical Imaging.

[5]  Alex Solomonoff,et al.  On the Gibbs phenomenon I: recovering exponential accuracy from the Fourier partial sum of a nonperiodic analytic function , 1992 .

[6]  Chi-Wang Shu,et al.  On the Gibbs Phenomenon and Its Resolution , 1997, SIAM Rev..

[7]  Anne Gelb,et al.  Spectral Reconstruction of Piecewise Smooth Functions from Their Discrete Data , 2002 .

[8]  Anne Gelb,et al.  The resolution of the Gibbs phenomenon for "spliced" functions in one and two dimensions , 1997 .

[9]  D. Gottlieb,et al.  Numerical analysis of spectral methods : theory and applications , 1977 .

[10]  P. T. Nowroji,et al.  On transcendental functions , 2001 .

[11]  Rick Archibald,et al.  Reducing the Effects of Noise in Image Reconstruction , 2002, J. Sci. Comput..

[12]  A. Erdélyi,et al.  Higher Transcendental Functions , 1954 .

[13]  Bertil Gustafsson,et al.  On the direct Fourier method for computer tomography , 2000, IEEE Transactions on Medical Imaging.

[14]  Alan C. Evans,et al.  An Extensible MRI Simulator for Post-Processing Evaluation , 1996, VBC.

[15]  Anne Gelb,et al.  Detection of Edges in Spectral Data , 1999 .

[16]  Stanley J. Reeves,et al.  A filter design method for minimizing ringing in a region of interest in MR spectroscopic images , 2000, IEEE Transactions on Medical Imaging.

[17]  Robert L. Stevenson,et al.  A Bayesian approach to image expansion for improved definitio , 1994, IEEE Trans. Image Process..

[18]  Weili Lin Principles of magnetic resonance imaging: a signal processing perspective [Book Review] , 2000, IEEE Engineering in Medicine and Biology Magazine.