Correlation-based aberration correction in the presence of inoperable elements

Estimation of phase aberrations using correlation processing between neighboring elements in a phased array is explored in the presence of inoperable elements. Using a CORDIC-based implementation of a complex baseband correlator, inactive elements can be identified simultaneous with correlation processing. Following detection of inoperable elements, a simple rerouting of the adaptive beam former is used to eliminate these elements from correlation analysis. Experimental results on a 3.33-MHz, 64-element array system with four contiguous, inactive elements demonstrate the robustness of the simple rerouting method for accurate phase aberration estimation.<<ETX>>

[1]  Jack E. Volder The CORDIC Trigonometric Computing Technique , 1959, IRE Trans. Electron. Comput..

[2]  Takuso Sato,et al.  Imaging through an inhomogeneous layer by least‐mean‐square error fitting , 1984 .

[3]  M. O'Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: measurements , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  M. O'Donnell,et al.  Phase Aberration Measurements in Medical Ultrasound: Human Studies , 1988 .

[5]  M. O’Donnell,et al.  Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principles , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  S. W. Smith,et al.  Phase aberration correction in medical ultrasound using speckle brightness as a quality factor. , 1989, The Journal of the Acoustical Society of America.

[7]  M. Nikoonahad,et al.  Real time ultrasonic phase conjugation , 1989, Proceedings., IEEE Ultrasonics Symposium,.

[8]  M. Fink,et al.  Self focusing in inhomogeneous media with time reversal acoustic mirrors , 1989, Proceedings., IEEE Ultrasonics Symposium,.

[9]  M. O'Donnell,et al.  Real-time Phase Aberration Correction System For Medical Ultrasound Imaging , 1990, [1990] Proceedings of the Twelfth Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  W.E. Engeler,et al.  Real-time phased array imaging using digital beam forming and autonomous channel control , 1990, IEEE Symposium on Ultrasonics.

[11]  D Rachlin Direct estimation of aberrating delays in pulse-echo imaging systems. , 1990, The Journal of the Acoustical Society of America.

[12]  M. O'Donnell,et al.  Aberration correction on a two-dimensional anisotropic phased array (medical US imaging) , 1991, IEEE 1991 Ultrasonics Symposium,.

[13]  Raoul Mallart,et al.  The van Cittert–Zernike theorem in pulse echo measurements , 1991 .