[Estimation of collimator scatter factor, S(c), of rectangular fields by a saturation model].

We estimated collimator scatter factor, S(c), of symmetric rectangular fields of any size by applying a two-component scatter model to measured in-air output data in width and length directions of measured rectangles. The in-air output was measured for symmetric rectangles with combined width and length sizes of 7 x 7 and 6 x 6 using 10 MV and 4 MV X-rays of Varian's Clinac 2100 C/D, respectively. The model consists of scatter components from the primary collimator and flattening filter and from the collimator jaws: the former shows a saturation curve and the latter increases linearly with enlarging field size. This model was fitted to the measured dataset firstly in the width and secondly in the length directions of rectangles; then, by compiling interpolated matrix data, the S(c) table of symmetric rectangles was constructed. In addition, using this S(c) table, values of S(c) were calculated for a few asymmetric rectangles by Day's method, and were in good agreement with measured values. Therefore, we think that our method is practical and precise for constructing the S(c) table of symmetric rectangles from measured data, and that using this table, the S(c) of any asymmetric rectangles may be calculated.

[1]  Lei Xing,et al.  A three-source model for the calculation of head scatter factors. , 2002, Medical physics.

[2]  P A Jursinic,et al.  Clinical implementation of a two-component x-ray source model for calculation of head-scatter factors. , 1997, Medical physics.

[3]  T C Zhu,et al.  An equivalent square field formula for determining head scatter factors of rectangular fields. , 1997, Medical physics.

[4]  R. Sloboda,et al.  Analytical representation of head scatter factors for shaped photon beams using a two-component x-ray source model. , 1995, Medical physics.

[5]  R. Sloboda,et al.  Parametrization of head-scatter factors for rectangular photon fields using an equivalent square formalism. , 1995, Medical physics.

[6]  B. Bjärngard,et al.  An equivalent-square formula for head-scatter factors. , 1993, Medical physics.

[7]  W Sewchand,et al.  Revision of tissue-maximum ratio and scatter-maximum ratio concepts for cobalt 60 and higher energy x-ray beams. , 1980, Medical physics.

[8]  T D STERLING,et al.  AUTOMATION OF RADIATION TREATMENT PLANNING. IV. DERIVATION OF A MATHEMATICAL EXPRESSION FOR THE PER CENT DEPTH DOSE SURFACE OF COBALT 60 BEAMS AND VISUALISATION OF MULTIPLE FIELD DOSE DISTRIBUTIONS. , 1964, The British journal of radiology.

[9]  M. J. Day A note on the calculation of dose in x-ray fields. , 1950, The British journal of radiology.

[10]  J. R. Clarkson,et al.  A Note on Depth Doses in Fields of Irregular Shape , 1941 .

[11]  M. J. Day The equivalent field method for axial dose determinations in rectangular fields. , 1972, The British journal of radiology.