Nonlinearity analysis in homodyne multi-pass interferometer with Jones matrix and correction with Fourier harmonic components method

The nonlinearity of the interferometer is an essential error in nanoscale measurements influenced by anisotropic gain and nonorthogonality of imperfect polarization components. In this paper, polarization error and the corresponding nonlinearity correction method are studied. The paper is divided into two parts, in the first part, main research focuses on the polarization mixing effect of multi-pass interferometer, besides this, polarization beam splitter and retardation plate are also analyzed, then a final synthetic evaluation is obtained through Jones matrix. In the second part, a harmonic separation method of interferometer signals is researched, the method first decomposes signals into Fourier series, then uses least square fitting to estimate coefficients of main terms of series. In the correction process, the primary phase angle is obtained through coefficients of base series and trigonometric formulas; the finer phase angle is obtained through coefficients of harmonics and Taylor expansion. Experimental results demonstrate that the nonlinearity of homodyne interferometer is significantly reduced in nanometer measurements.

[1]  K. P. Birch,et al.  Optical fringe subdivision with nanometric accuracy , 1990 .

[2]  Chien-ming Wu Periodic nonlinearity resulting from ghost reflections in heterodyne interferometry , 2003 .

[3]  Walter Augustyn,et al.  An analysis of polarization mixing errors in distance measuring interferometers , 1990 .

[4]  Yuanlong Deng,et al.  Analysis of frequency mixing error on heterodyne interferometric ellipsometry , 2007 .

[5]  Wenmei Hou,et al.  Drift of nonlinearity in the heterodyne interferometer , 1994 .

[6]  Wenmei Hou,et al.  Investigation and compensation of the nonlinearity of heterodyne interferometers , 1992 .

[7]  Janez Mozina,et al.  Quadrature phase-shift error analysis using a homodyne laser interferometer. , 2009, Optics express.

[8]  Wenmei Hou Optical parts and the nonlinearity in heterodyne interferometers , 2006 .

[9]  J. Lawall,et al.  Heterodyne interferometer with subatomic periodic nonlinearity. , 1999, Applied optics.

[10]  Ichiko Misumi,et al.  Simple, real-time method for removing the cyclic error of a homodyne interferometer with a quadrature detector system. , 2005, Applied optics.

[11]  P L Heydemann,et al.  Determination and correction of quadrature fringe measurement errors in interferometers. , 1981, Applied optics.

[12]  Ichiko Misumi,et al.  Removing nonlinearity of a homodyne interferometer by adjusting the gains of its quadrature detector systems. , 2004, Applied optics.

[13]  Chien‐Ming Wu,et al.  Nonlinearity in measurements of length by optical interferometry , 1996 .

[14]  Gwo-Sheng Peng,et al.  Correction of nonlinearity in one-frequency optical interferometry , 1996 .