A reduced-order model for electrically actuated clamped circular plates

We present an analytical reduced-order model (macromodel) for an electrically actuated clamped circular plate. After establishing the equations governing the plate, we discretize the system by using a Galerkin approach. The distributed-parameter equations are then reduced to a finite system of ordinary-differential equations in time. We solve these equations for the equilibrium states due to a general electric potential and determine the natural frequencies of the axisymmetric modes for the stable deflected position. Finally, we attempt to validate the model by using data from experiments performed on silicon-based microelectromechanical systems (MEMS). The reduced-order model accounts for both geometric nonlinear hardening and residual stress, allows for general design variables and is also robust up to the pull-in instability. Consequently, our macromodel is general and computationally strong enough to be an effective design tool.

[1]  Giosue Caliano,et al.  An accurate model for capacitive micromachined ultrasonic transducers , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  A. Nayfeh,et al.  Mechanical Behavior of an Electrostatically Actuated Micropump , 2002 .

[3]  K. Suzuki,et al.  A silicon electrostatic ultrasonic transducer , 1989, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  O. Oralkan,et al.  Volumetric ultrasound imaging using 2-D CMUT arrays , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  A.S. Ergun,et al.  Fabrication of Capacitive Micromachined Ultrasonic Transducers (CMUTs) using wafer bonding technology for low frequency (10 kHz-150 kHz) sonar applications , 2002, OCEANS '02 MTS/IEEE.

[6]  I. Ladabaum,et al.  Theory and analysis of electrode size optimization for capacitive microfabricated ultrasonic transducers , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  B. Khuri-Yakub,et al.  Surface micromachined capacitive ultrasonic immersion transducers , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[8]  D. Greve,et al.  Electrical characterization of coupled and uncoupled MEMS ultrasonic transducers , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  Ali H. Nayfeh,et al.  A reduced-order model for electrically actuated microbeam-based MEMS , 2003 .

[10]  J. Pelesko Multiple Solutions in Electrostatic MEMS , 2001 .

[11]  B. Khuri-Yakub,et al.  Characterization of one-dimensional capacitive micromachined ultrasonic immersion transducer arrays , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  Ali H. Nayfeh,et al.  A Reduced-Order Model for Electrically Actuated Clamped Circular Plates , 2003 .

[13]  D. Marioli,et al.  Piezoelectric thick-film fluid density sensor based on resonance vibration , 1998, IMTC/98 Conference Proceedings. IEEE Instrumentation and Measurement Technology Conference. Where Instrumentation is Going (Cat. No.98CH36222).

[14]  New fabrication process for Capacitive Micromachined Ultrasonic Transducers , 2003, The Sixteenth Annual International Conference on Micro Electro Mechanical Systems, 2003. MEMS-03 Kyoto. IEEE.

[15]  A.S. Ergun,et al.  Fabrication and characterization of 1-dimensional and 2-dimensional Capacitive Micromachined Ultrasonic Transducer (CMUT) arrays for 2-dimensional and volumetric ultrasonic imaging , 2002, OCEANS '02 MTS/IEEE.

[16]  Christofer Hierold,et al.  Surface micromachined ultrasound transducers in CMOS technology , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[17]  R. Carotenuto,et al.  Vibration maps of capacitive micromachined ultrasonic transducers by laser interferometry , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  B. Bayram,et al.  Residual stress and Young's modulus measurement of capacitive micromachined ultrasonic transducer membranes , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[19]  Nesbitt W. Hagood,et al.  Design, fabrication, and testing of a piezoelectrically driven high flow rate micro-pump , 2000, ISAF 2000. Proceedings of the 2000 12th IEEE International Symposium on Applications of Ferroelectrics (IEEE Cat. No.00CH37076).

[20]  B. Khuri-Yakub,et al.  A surface micromachined electrostatic ultrasonic air transducer , 1996, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  B. Bayram,et al.  Influence of the electrode size and location on the performance of a CMUT [US transducer] , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[22]  B. Khuri-Yakub,et al.  Piezoelectrically actuated flextensional MUTs , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[23]  Edward Hæggström,et al.  Fabricating capacitive micromachined ultrasonic transducers with wafer-bonding technology , 2003 .

[24]  A. Nayfeh,et al.  Applied nonlinear dynamics : analytical, computational, and experimental methods , 1995 .

[25]  B.T. Khuri-Yakub,et al.  Calculation and measurement of electromechanical coupling coefficient of capacitive micromachined ultrasonic transducers , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.