Semi-Quantitative Method for Streptococci Magnetic Detection in Raw Milk

Bovine mastitis is the most costly disease for dairy farmers and the most frequent reason for the use of antibiotics in dairy cattle; thus, control measures to detect and prevent mastitis are crucial for dairy farm sustainability. The aim of this study was to develop and validate a sensitive method to magnetically detect Streptococcus agalactiae (a Group B streptococci) and Streptococcus uberis in raw milk samples. Mastitic milk samples were collected aseptically from 44 cows with subclinical mastitis, from 11 Portuguese dairy farms. Forty-six quarter milk samples were selected based on bacterial identification by conventional microbiology. All samples were submitted to PCR analysis. In parallel, these milk samples were mixed with a solution combining specific antibodies and magnetic nanoparticles, to be analyzed using a lab-on-a-chip magnetoresistive cytometer, with microfluidic sample handling. This paper describes a point of care methodology used for detection of bacteria, including analysis of false positive/negative results. This immunological recognition was able to detect bacterial presence in samples spiked above 100 cfu/mL, independently of antibody and targeted bacteria used in this work. Using PCR as a reference, this method correctly identified 73% of positive samples for streptococci species with an anti-S. agalactiae antibody, and 41% of positive samples for an anti-GB streptococci antibody.

[1]  Performance Studies of an Enzyme-Linked Immunosorbent Assay for Detecting Staphylococcus Aureus Antibody in Bovine Milk , 1990, Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc.

[2]  M. Groschup,et al.  Antigenic and genetic homogeneity of Streptococcus uberis strains from the bovine udder , 1991, Epidemiology and Infection.

[3]  T. Sagara,et al.  Magnetoresistive Sensors , 1993, IEEE Translation Journal on Magnetics in Japan.

[4]  W. Sischo,et al.  Comparison of microbiologic culture, an enzyme-linked immunosorbent assay, and determination of somatic cell count for diagnosing Staphylococcus aureus mastitis in dairy cows. , 1994, Journal of the American Veterinary Medical Association.

[5]  B. Poutrel,et al.  Bovine mastitis caused by Listeria monocytogenes: kinetics of antibody responses in serum and milk after experimental infection. , 1996, Journal of dairy science.

[6]  A. Kling,et al.  Ion beam deposition of Mn-Ir spin valves , 1999 .

[7]  A. Bradley Bovine mastitis: an evolving disease. , 2002, Veterinary journal.

[8]  M. W. van der Woude,et al.  Phase and Antigenic Variation in Bacteria , 2004, Clinical Microbiology Reviews.

[9]  Pieter Walstra,et al.  Dairy Science and Technology , 2005 .

[10]  Satu Pyörälä,et al.  Accuracy and reliability of mastitis detection with electrical conductivity and milk colour measurement in automatic milking , 2006 .

[11]  Olivier Lazcka,et al.  Pathogen detection: a perspective of traditional methods and biosensors. , 2007, Biosensors & bioelectronics.

[12]  R. Tripp,et al.  Emerging Technologies in Nanotechnology-Based Pathogen Detection , 2009 .

[13]  S. Taponen,et al.  Real-time polymerase chain reaction-based identification of bacteria in milk samples from bovine clinical mastitis with no growth in conventional culturing. , 2009, Journal of dairy science.

[14]  J. Holopainen,et al.  Analytical specificity and sensitivity of a real-time polymerase chain reaction assay for identification of bovine mastitis pathogens. , 2009, Journal of dairy science.

[15]  J Loureiro,et al.  Magnetoresistive chip cytometer. , 2011, Lab on a chip.

[16]  R. Zadoks,et al.  Molecular Epidemiology of Mastitis Pathogens of Dairy Cattle and Comparative Relevance to Humans , 2011, Journal of Mammary Gland Biology and Neoplasia.

[17]  P P Freitas,et al.  Spintronic platforms for biomedical applications. , 2012, Lab on a chip.

[18]  R. Boss,et al.  Phenotypic and genotypic identification of streptococci and related bacteria isolated from bovine intramammary infections , 2013, Acta Veterinaria Scandinavica.

[19]  Filipe Arroyo Cardoso,et al.  Lab-on-Chip Cytometry Based on Magnetoresistive Sensors for Bacteria Detection in Milk , 2014, Sensors.

[20]  Leandro Lorenzelli,et al.  Recent sensing technologies for pathogen detection in milk: a review. , 2014, Biosensors & bioelectronics.

[21]  Moisés Simões Piedade,et al.  A Neuronal Signal Detector for Biologically Generated Magnetic Fields , 2014, IEEE Transactions on Instrumentation and Measurement.

[22]  Performance of a real-time PCR assay in routine bovine mastitis diagnostics compared with in-depth conventional culture , 2015, Journal of Dairy Research.

[23]  On the importance of sensor height variation for detection of magnetic labels by magnetoresistive sensors , 2015, Scientific reports.

[24]  Filipe Arroyo Cardoso,et al.  Magnetic Counter for Group B Streptococci Detection in Milk , 2015, IEEE Transactions on Magnetics.

[25]  Amy C. Valenciano,et al.  Sample Collection and Handling , 2017 .