Experimental and numerical study of an evaporatively-cooled condenser of air-conditioning systems

The performance of an air-conditioning unit with evaporately-cooled condenser coil is studied experimentally and numerically. An experimental setup is fabricated by retrofitting a commercially available air-conditioning unit and installing comprehensive measuring sensors and controllers. Experimental result shows that the COP (Coefficient of Performance) of the evaporately-cooled air-conditioning unit increases by about 28% compared to the conventional air cooled air-conditioning unit. To analyze the heat and mass transfer processes involved in the evaporately-cooled condenser, a detailed theoretical model has been developed based on the fluid flow characteristics of the falling film and the thermodynamic aspect of the evaporation process. Simulated results agree well with experimental data. The numerical model provides new insights into the intrinsic links between operating variables and heat transfer characteristics of water film in evaluating the performance of evaporatively-cooled condenser system. Two heat transfer coefficients, namely, wall to bulk and bulk to interface are introduced and computed from the simulation results under different operating conditions. Finally, the overall heat transfer coefficient for the water film is computed and presented as a function of dimensionless variables which can conveniently be employed by engineers to design and analyze high performance evaporatively-cooled heat exchangers.

[1]  Jae-Weon Jeong,et al.  Cooling performance of a 100% outdoor air system integrated with indirect and direct evaporative coolers , 2013 .

[2]  M. Hassan,et al.  Experimental and theoretical investigation of an innovative evaporative condenser for residential refrigerator , 2009 .

[3]  J. Guilpart,et al.  Numerical model of sprayed air cooled condenser coupled to refrigerating system , 2007 .

[4]  Ala Hasan,et al.  Performance investigation of plain and finned tube evaporatively cooled heat exchangers , 2003 .

[5]  T. Wang Experimental investigation of air conditioning system using evaporative cooling condenser , 2014 .

[6]  Don W. Green,et al.  Perry's Chemical Engineers' Handbook , 2007 .

[7]  Pascal Boulet,et al.  Improved energy performance of a refrigerating machine using water spray upstream of the condenser , 2014 .

[8]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[9]  P. K. Sarma,et al.  Evaporation of laminar, falling liquid film on a horizontal cylinder , 1992 .

[10]  Michalis Gr. Vrachopoulos,et al.  Incorporated evaporative condenser , 2007 .

[11]  Douglas T. Reindl,et al.  Evaporative condenser control in industrial refrigeration systems , 2001 .

[12]  Chander P Arora,et al.  Refrigeration and Air Conditioning , 1983 .

[13]  E. Hajidavalloo,et al.  Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser. , 2010 .

[14]  Ebrahim Hajidavalloo,et al.  Application of evaporative cooling on the condenser of window-air-conditioner , 2007 .

[15]  Haruki Sato,et al.  Proposal of an eco-friendly high-performance air-conditioning system. Part 1. Possibility of improving existing air-conditioning system by an evapo-transpiration condenser , 2013 .

[16]  Refrigerating ASHRAE handbook and product directory /published by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc , 1977 .

[17]  Demis Pandelidis,et al.  Numerical study and optimization of the combined indirect evaporative air cooler for air-conditioning systems , 2015 .

[18]  Bin-Juine Huang,et al.  Study of a high efficiency residential split water-cooled air conditioner , 2005 .