Establishment of the Detailed Breast Model of Chinese Adult Female and Application in External Radiation Protection

Breast is one of the most sensitive organs to radiation. In 2007, International Commission on Radiological Protection (ICRP) increased the tissue weighting factor for the breast from 0.05 to 0.12, which made the accurate evaluation of breast dose more important. But in the existing human voxel phantom, the structure of breast is not elaborate enough because of the limitation of image resolution used for phantom modeling. This will probably affect the accuracy of breast dose calculated in simulation. Some researches on detailed breast modeling have been carried out, but there is no such research in this field in China. A detailed breast model for Chinese adult female is established in this article using the mathematical modeling method. It is voxelized and merged with the Chinese reference adult female voxel model for breast dosimetry. Dose conversion coefficients of breast gland for external photon exposures in antero-posterior geometry are calculated as an example of the application and the results are compared with those calculated by the old voxel phantom and ICRP reference adult female voxel phantom.

[1]  Icrp 1990 Recommendations of the International Commission on Radiological Protection , 1991 .

[2]  A. Dell'Acqua,et al.  Geant4 - A simulation toolkit , 2003 .

[3]  Michael F. Insana,et al.  Three-Dimensional In Silico Breast Phantoms for Multimodal Image Simulations , 2012, IEEE Transactions on Medical Imaging.

[4]  Christoph Hoeschen,et al.  A high-resolution voxel phantom of the breast for dose calculations in mammography. , 2005, Radiation protection dosimetry.

[5]  John M Boone,et al.  Methodology for generating a 3D computerized breast phantom from empirical data. , 2009, Medical physics.

[6]  Andrew D. A. Maidment,et al.  Mammogram synthesis using a 3D simulation. I. Breast tissue model and image acquisition simulation. , 2002, Medical physics.

[7]  Paul DeLuca,et al.  Realistic reference phantoms: An ICRP/ICRU joint effort , 2009, Annals of the ICRP.

[8]  N Petoussi-Henss,et al.  Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures , 2010, Annals of the ICRP.

[9]  Jack Valentin,et al.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. , 2007, Annals of the ICRP.

[10]  Li Junli Chinese reference digital voxel phantoms for radiation protection systems , 2012 .

[11]  K Bliznakova,et al.  A three-dimensional breast software phantom for mammography simulation. , 2003, Physics in medicine and biology.

[12]  Daniel J et.all Dronkers The Practice of Mammography: Pathology-Technique-Interpretation-Adjunct Modalities , 2002 .

[13]  Robert L. Egan,et al.  Breast Imaging: Diagnosis and Morphology of Breast Diseases , 1988 .

[14]  Andrew D. A. Maidment,et al.  Development and characterization of an anthropomorphic breast software phantom based upon region-growing algorithm. , 2011, Medical physics.