Background and Purpose Patent foramen ovale is associated with ischemic stroke in patients without a clearly identifiable etiology for stroke (cryptogenic stroke). Paradoxical embolization is thought to be a potential mechanism. How- ever, patent foramen ovale is also found in patients with known cause of stroke. Therefore, using contrast transesophageal echocardiography, we characterized the patent foramen ovale in cryptogenic stroke patients to assess morphological factors that may contribute to paradoxical embolization. Methods Contrast transesophageal echocardiographic studies of 74 consecutive patients referred for ischemic stroke were reviewed. Twenty-three patients with patent foramen ovale were identified. These patients were classified as having strokes of determined origin or cryptogenic strokes according to criteria developed for the Stroke Data Bank of the National Institute of Neurological Disorders and Stroke. Separation of septum primum from secundum and the number of microbubbles appearing in left atrium were then quantitated. These parameters were compared between patients with cryptogenic stroke and those with known cause of stroke. Results The patent foramen ovale dimension was significantly larger in patients with cryptogenic stroke compared with patients with an identifiable cause of stroke (2.1 ±1.7 mm versus 0.57±0.78 mm [mean±SD]; P<.01). The number of microbubbles was also greater in patients with cryptogenic stroke compared with patients with an identifiable cause of stroke (13.9±10.7 versus 1.6±0.8 [mean±SD]; P<.0O05). Conclusions Patients with cryptogenic stroke have larger patent foramen ovale with more extensive right-to-left interatrial shunting than patients with stroke of determined cause. Transesophageal echocardiographically identifiable characteristics of patent foramen ovale may be important in defining the clinical significance of individual patent foramina.

[1]  H. Leitner,et al.  The Prevalence of Deep Venous Thrombosis in Patients with Suspected Paradoxical Embolism , 1993, Annals of Internal Medicine.

[2]  J. Mohr,et al.  Classification and diagnosis of stroke , 1984 .

[3]  C. Tei,et al.  Hemodynamic Determinants of Pulmonary Valve Motion During Systole in Experimental Pulmonary Hypertension , 1981, Circulation.

[4]  C. Stöllberger,et al.  Detection of patent foramen ovale by transcranial contrast Doppler ultrasound. , 1992, The American journal of cardiology.

[5]  R. Popp,et al.  Transesophageal Echocardiography in the Evaluation of Stroke , 1992, Annals of Internal Medicine.

[6]  R. Sacco,et al.  Patent foramen ovale: a new risk factor for ischemic stroke. , 1993, Heart disease and stroke : a journal for primary care physicians.

[7]  W. Edwards,et al.  Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. , 1984, Mayo Clinic proceedings.

[8]  A. Labovitz,et al.  Atrial septal aneurysm and stroke: a transesophageal echocardiographic study. , 1991, Journal of the American College of Cardiology.

[9]  R. Hart,et al.  Current Concepts of Cerebrovascular Disease — Stroke Cerebral Infarction in Young Adults: A Practical Approach , 2008 .

[10]  Daniel B Hier,et al.  Infarcts of undetermined cause: The NINCDS stroke data bank , 1989, Annals of neurology.

[11]  M. Bochner,et al.  Paradoxical embolus , 1993, The Medical journal of Australia.

[12]  R. Sacco,et al.  Patent Foramen Ovale as a Risk Factor for Cryptogenic Stroke , 1992, Annals of Internal Medicine.

[13]  J. Kisslo,et al.  Atrial septal aneurysm: association with cerebrovascular and peripheral embolic events. , 1987, Stroke.

[14]  W. Daniel Transcatheter closure of patent foramen ovale. Therapeutic overkill or elegant management for selected patients at risk? , 1992, Circulation.

[15]  D. Ranoux,et al.  Patent foramen ovale: is stroke due to paradoxical embolism? , 1993, Stroke.

[16]  P. Yock,et al.  Noninvasive estimation of right ventricular systolic pressure by Doppler ultrasound in patients with tricuspid regurgitation. , 1984, Circulation.

[17]  M. Cohen,et al.  Left ventricular systolic circular index: an echocardiographic measure of transseptal pressure ratio. , 1987, American heart journal.

[18]  H. J. Smith,et al.  PATENT FORAMEN OVALE IN YOUNG STROKE PATIENTS , 1988, The Lancet.

[19]  S. Black,et al.  Intraoperative detection of patent foramen ovale by transesophageal echocardiography. , 1991, Anesthesiology.

[20]  S. Teague,et al.  Detection of paradoxical cerebral echo contrast embolization by transcranial Doppler ultrasound. , 1991, Stroke.

[21]  P. Lechat,et al.  Prevalence of patent foramen ovale in patients with stroke. , 1988, The New England journal of medicine.

[22]  R. Sacco,et al.  Comparison of Diagnostic Techniques for the Detection of a Patent Foramen Ovale in Stroke Patients , 1993, Stroke.

[23]  J. Newburger,et al.  Transcatheter Closure of Patent Foramen Ovale After Presumed Paradoxical Embolism , 1992, Circulation.

[24]  F. Pinto,et al.  Biplane transesophageal echocardiography in the diagnosis of patent foramen ovale. , 1993, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[25]  M. Kotler,et al.  Patent foramen ovale: a nonfunctional embryological remnant or a potential cause of significant pathology? , 1992, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[26]  J. Anderson,et al.  Clinically silent atrial septal defects with evidence for cerebral embolization. , 1986, Annals of internal medicine.

[27]  R. G. Anderson,et al.  Paradoxical embolism. , 1946, British medical journal.